SIP 06787 Manual Download Page 5

12 

The  following  form  lists  the  common  operating  issues  with  problems  and  solutions. 

Please read the form carefully and follow it.

 

If any of the following symptoms occurs during your operation, stop using the tool immediately, or serious 
personal injury could result. Only a qualified person or an authorised service centre should perform repairs  
of the tool. Disconnect from the air supply before attempting repairs or adjustments. When replacing O-
rings etc. lubricate with air tool oil before assembly. 

  TROUBLESHOOTING 

PROBLEMS 

POSSIBLE CAUSES 

REMEDIES 

Tool runs at normal speed       

but struggles under load. 

 
 

Motor parts worn. 

 

Check / have the parts checked and re-
pair / replace as necessary. 

 
 
 
 
 

NOTE: Heat usually indicates insufficient 
grease in gears. Severe operating condi-
tions may require more frequent lubrica-
tion. 

 Tool runs slowly. Air flows 

slightly from exhaust. 

 

 

Inlet filter restricted. 
Motor parts jammed with 
dirt particles. 
Air flow blocked by dirt. 

 

Check air inlet filter for blockage. 
Pour air tool lubricating oil into air inlet, 
operate tool in short bursts quickly reversing 
rotation back and forth where applicable. 
Repeat above as needed. If this fails return 
to service centre. 

Tools will not run. Air flows 

freely from exhaust. 

 
 
 
 
 

One or more motor vanes 
stuck due to material build 
up. 

 
 
 
 
 

Pour air tool lubricating oil into air inlet, 
operate tool in short bursts quickly reversing 
rotation back and forth where applicable. 
Tap motor housing gently with plastic mal-
let. 
Disconnect supply; Free motor by rotating 
drive shank manually where applicable 
If tool remains jammed return to service 
centre. 

Tool will not shut off. 
 

‘O’ rings throttle valve dis-
lodged from seat inlet 
valve. 

Replace ‘O’ ring or return to service centre. 

 
 

                                       Note: Repairs should be carried out by a qualified person. 

  SAFETY INSTRUCTIONS….cont 

DO NOT 

dismantle or tamper with the impact wrench, as this may be dangerous and 

will invalidate the warranty.  

If a problem with the impact wrench is experienced or suspected stop using the im-

pact wrench immediately and contact your distributor for repair.  
Regularly inspect and lubricate the impact wrench, ensuring that it is in good working 

order and condition.  
Always ensure that the work area is clean and tidy, free from unrelated materials and 

has adequate lighting.  
Clean and stow the impact wrench correctly.  
Failure to follow the warnings in this manual, may result in personal injury and/or prop-

erty damage.  

DO

 ensure that only compressed air is used to supply the air tool.  

The compressed air supply MUST be at a suitable regulated pressure. Pipe work, reg-

ulators, hoses, isolation valves  and connection devices MUST be suitable for the in-

tended application correctly installed and maintained in good condition by a com-

petent person. 
Appropriate Personal protective equipment MUST be worn and MUST be designed to 

protect  against  all  hazards  created.  Severe  permanent  injury  can  result  from using 

inappropriate or insufficient protective equipment - Eyes in particular are at risk.  
Long hair MUST be tied back; loose clothing MUST NOT be worn. There is a severe risk 

of these being drawn in or trapped by the moving parts of the air tool. 
Open or damaged compressed air lines present a significant ‘whip’ hazard; isolate 

the problem hose from the air supply and repair / replace the hose immediately.  
This air tool is electrically conductive DO NOT allow them to come into contact with 

any source of electrical supply.  
After use wait for the air tool to STOP completely before putting it aside.  
When putting the air tool aside you MUST ensure that it placed in a stable position. To 

avoid inadvertent operation DO NOT place the air tool where it can be knocked or 

moved accidentally either directly or by the air connection hose.  
If  the  air  tool  is  not  required  or  the  air  supply  is  interrupted,  disconnect  the  air  tool 

from the air supply and place in secure storage to prevent unauthorised use.  
Ensure the air valve (or trigger) is in the “off” position before connecting to the air sup-

ply.  
Disconnect  the  impact  wrench  from  the  air  supply  before  making  adjustments, 

changing impact wrench bits etc. and before servicing the tool.  
Always keep your air tool clean and lubricated. Daily lubrication is essential to avoid 

internal corrosion and possible failure.  
Do not overload the tool. Allow the tool to operate at its optimum speed for maxi-

mum efficiency.  
Do not increase the air pressure above the manufacturers recommended level, as 

excessive pressure can cause the tool casing to split. This can also create excessive 

wear on moving parts and possible failure.  

Summary of Contents for 06787

Page 1: ...f 230914 Please dispose of packaging for the product in a responsible manner It is suitable for recycling Help to protect the environment take the packaging to the local amenity tip and place into the...

Page 2: ...sed representative within the EC declare that the Air Impact Wrench SIP Part No 06787 Conforms to the requirements of the following directive s as indicated 2006 42 EC Machinery Directive Signed Mr P...

Page 3: ...00147 35 Spring AI05 00170 13 Oil seal AI05 00148 36 O ring 8 5 1 8 AI05 00171 14 Front End plate AI05 00149 37 Air Regulator AI05 00172 15 Rotor blade AI05 00150 38 Bolt AI05 00173 16 Rotor AI05 0015...

Page 4: ...t us and we will be more than happy to advise you Before operating the impact wrench always check no parts are broken and that no parts are missing Always operate the impact wrench safely and correctl...

Page 5: ...that the work area is clean and tidy free from unrelated materials and has adequate lighting Clean and stow the impact wrench correctly Failure to follow the warnings in this manual may result in pers...

Page 6: ...ays ensure that the accessories such as impact wrench bits are rated designed for use with this impact wrench as well as the required application and are correctly and securely fastened before connect...

Page 7: ...adjusted Without proper lubrication the tool will not work properly and parts will wear prematurely Use the proper lubricant in the air line lubricator The lubricator should be of low air flow or chan...

Page 8: ...re connecting to the air supply 2 You will require an air pressure of 90psi and an air flow according to specifica tion 3 WARNING Ensure the air supply is clean and does not exceed 90psi while oper at...

Reviews: