Sinvest VGE Blue Lagoon AOP COMPACT OZONE & UV-C 75W Manual Download Page 6

EN

6

 

 

|  BLUE LAGOON AOP COMPACT OZONE & UV-C 75W & AOP COMPACT OZONE & UV-C 75W SALTWATER

INSTALLATION OF THE EARTH (DRAWING 2)

1.  Pull the cable (2) through the strain relief (4) before fitting the synthetic strain relief (4) onto the earth 

bolt (1). Position the strain relief (4) at approximately 10 cm from the eye (2) of the earth cable.

2.  Place the eye (2) of the cable onto the earth bolt that is fitted to the housing.
3.  Then place a toothed lock washer (3).
4.  Fit the strain relief (4), creating a loop of Ø 5 cm.
5.  Finally place the second toothed lock washer (5) and the lock nut (6) onto the earth bolt.
6.  Once the parts have been placed onto the earth bolt in the correct sequence, they can be 

tightened with a spanner or a ring spanner number 8. 

INSTALLATION OF THE DEVICE (SEE DRAWING 3)

Determine where the device will be installed. The Blue Lagoon AOP Compact Ozone & UV-C 75W 
must never be installed behind the Ph regulator or the salt electrolysis system in your swimming 
pool installation. The ideal location to install your device is immediately behind the filter. The 
installation must always take place outside of the pool. Ensure that there is always water flowing 
through the unit when the lamp is on. Never install the unit in an area exposed to full sunlight. 
The installation must always take place in a dry and well-ventilated area. The device must always 
be fitted in the vertical position, and a space of 30 cm must be available underneath to carry out 
maintenance. An area of approx. 1.5 m must be available at the top in order to be able to replace the 
lamp (Q) smoothly without having to dismantle the complete device.
1.  Fit the manometer (I) onto the Venturi system using Teflon tape (not included in the delivery). 

Hand-tighten the manometer.

2.  Glue the entire Venturi system (K) onto the inlet (N) of the device using the supplied Ø 63-50 mm 

glued socket (L). The Venturi system must be mounted onto the device in a horizontal position. 
The glued socket (L) has a screw thread on one side; when gluing the glued socket, ensure that 
the screw thread is inserted into the inlet (N). 

3.  Take the hose with the non-return valve (M). Fit the short section of the hose to the bottom 

side of the device on the hose (P). Place the long section of the hose onto the adapter (Z) of the 
Venturi system.

4.  Then mount the complete device, including the Venturi system, at the desired place between the piping.
5.  Fit the unit with the supplied pipe clips (O) in a fixed position and hand-tighten the 3-part 

couplings (S). Never use a wrench, tongs or other tools to tighten synthetic parts. 

6.  Activate the pump and check that there is flow and no leakage in the system. 
7.  Insert the plug of the UV-C device into a wall socket with a safety ground. Check whether the 

lamp (Q) is operating via the transparent outlet (R) of the unit.

8.  The quantity of ozone air in the system can be adjusted using the ball valve (J). The closer the 

ball valve is positioned, the more ozone air will enter the system. The ideal position on the 
manometer is between 0.4 and 0.7 bar.

Important

 read this manual carefully before proceeding 

to installation and commissioning.

AOP COMPACT OZONE & UV-C 75W
AOP COMPACT OZONE & UV-C 75W SALT WATER

Summary of Contents for VGE Blue Lagoon AOP COMPACT OZONE & UV-C 75W

Page 1: ...UV C and Pool equipment AOP COMPACT OZONE UV C 75W AOP COMPACT OZONE UV C 75W SALTWATER www bluelagoonuvc com MEMBER OF...

Page 2: ...2 BLUE LAGOON AOP COMPACT OZONE UV C 75W AOP COMPACT OZONE UV C 75W SALTWATER...

Page 3: ...agoon AOP Compact Ozone UV C 75W EN 6 9 Blue Lagoon AOP Compact Ozone UV C 75W DE 10 14 Blue Lagoon AOP Compact Ozone UV C 75W FR 15 18 Blue Lagoon AOP Compact Ozone UV C 75W NL 19 23 Blue Lagoon AOP...

Page 4: ...6 5 4 3 2 1 2 1 4 5 4 BLUE LAGOON AOP COMPACT OZONE UV C 75W AOP COMPACT OZONE UV C 75W SALTWATER AOP COMPACT OZONE UV C 75W AOP COMPACT OZONE UV C 75W SALTWATER...

Page 5: ...0 bar 1 5 0 5 1 0 3 BLUE LAGOON AOP COMPACT OZONE UV C 75W AOP COMPACT OZONE UV C 75W SALTWATER 5 UV C and Pool equipment U V Q X T M W S O R N L Z O K I J P A Y...

Page 6: ...ox 1 5 m must be available at the top in order to be able to replace the lamp Q smoothly without having to dismantle the complete device 1 Fit the manometer I onto the Venturi system using Teflon tape...

Page 7: ...at the user menu has been selected Once the switch T has been released the meter indication and rSt will blink alternately on the display It is now possible to step through the menu options by briefly...

Page 8: ...hour position 0336 the display will blink every half second The lamp must be replaced within 2 weeks From hour position 0168 the display will blink every second The lamp must be replaced in 1 week s t...

Page 9: ...When re installing the lamp and or the quartz glass the housing must be in a vertical position in order to prevent damage to the lamp and the quartz glass 7 Unscrew the screw cap at the bottom of the...

Page 10: ...ss ca 1 5 m Platz bleiben damit die Lampe Q problemlos ausgewechselt werden kann ohne dass das ganze Ger t abgebaut werden muss 1 Manometer I am Venturi anbringen Dazu Teflonband verwenden nicht mitge...

Page 11: ...n des Stundenz hlers ggf ndern Dabei gehen Sie folgenderma en vor Wenn Sie den Schalter T unter dem Display 5 Sekunden eingedr ckt halten erscheint auf dem Display rSt um anzuzeigen dass das Benutzerm...

Page 12: ...4500 zur cksetzen indem Sie den Schalter 5 Sekunden eingedr ckt halten Der Z hlerstand betr gt dann wieder 4500 und es kann ein neuer Wert eingestellt werden Der Stundenz hler zeigt auf die folgende W...

Page 13: ...iehen 1 Die dreiteiligen Kupplungen l sen und das Wasser aus dem Ger t str men lassen 2 Die Rohrschellen ffnen und das Ger t vorsichtig aus den Halterungen ziehen 3 Die Mutter oben am Ger t U losschra...

Page 14: ...nge des Ger ts 100 cm Breite des Ger ts einschlie l Reaktor 75 cm Artikelnummer BH03752 Blue Lagoon AOP Compact Ozone UV C 75W 230V 50 60Hz Artikelnummer BH09752 Blue Lagoon AOP Compact Ozone UV C 75W...

Page 15: ...tie sup rieure il faut laisser un espace d env 1 5 m afin de pouvoir remplacer sans probl me la lampe Q sans devoir d monter l ensemble de l appareil 1 Monter le manom tre I sur le venturi Utiliser du...

Page 16: ...r et rSt clignotent sur l cran En appuyant ensuite bri vement sur l interrupteur il est possible de naviguer parmi les param tres du menu Il existe 3 possibilit s de param trage rSt UP et dn rSt signi...

Page 17: ...chaque quart de seconde La lampe doit tre remplac e dans 1 semaine A la valeur horaire 0000 les chiffres clignotent rapidement et constamment et le compte rebours est termin La lampe doit tre remplac...

Page 18: ...u du verre de quartz le logement doit tre positionn la verticale Ceci afin d viter tout endommagement de la lampe et du verre de quartz 7 D visser le couvercle la partie inf rieure de l appareil Poser...

Page 19: ...1 5 m ruimte zijn om de lamp Q probleemloos te kunnen vervangen zonder het hele apparaat te hoeven losmaken 1 Monteer de mano meter I op de venturi Gebruik hier voor teflon tape niet bijgeleverd Draa...

Page 20: ...d en rSt afwisselend op de display Door hierna de schakelaar kort in te drukken wordt door het mogelijkheden van het menu gestapt Er zijn 3 instelmogelijkheden in het menu rSt UP en dn rSt betekent re...

Page 21: ...e halve seconde De lamp dient over 2 weken vervangen te worden Vanaf urenstand 0168 display knippert om seconde De lamp dient over 1 week vervangen te worden Bij een urenstand van 0000 blijven de cijf...

Page 22: ...aan de bovenkant van het apparaat U los neem de lamp aansluiting uit de behuizing en koppel de lamp van de gele lamphouder V los 4 Trek nu voorzichtig de lamp Q uit het kwartsglas X 5 Indien het kwar...

Page 23: ...ansluiting 63 mm Lengte apparaat 100 cm Breedte apparaat incl reactor 75 cm Artikel nummer BH03752 Blue Lagoon AOP Compact Ozone UV C 75W 230V 50 60Hz Artikel nummer BH09752 Blue Lagoon AOP Compact Oz...

Page 24: ...ci n vertical dejando en la parte inferior un espacio libre de 30 cm para el caso de que haya que realizar trabajos de mantenimiento En la parte superior deber quedar 1 5 metros de espacio para poder...

Page 25: ...mismo la indicaci n del cuentahoras se mostrar la ltima posici n del cuentahoras que aparec a en el visor antes de desactivarse ste Los ajustes del cuentahoras se pueden modificar si se desea Esto se...

Page 26: ...eccionadas las horas que se desea se deber esperar 10 segundos A los 10 segundos aparece en el visor el n mero de horas seleccionado y se inicia la cuenta atr s del temporizador En caso de que se equi...

Page 27: ...l ctrica La l mpara especial se deber sustituir despu s de 4 500 horas de servicio Para el mantenimiento o el desmontaje se deber n tener los planos o dibujos siempre a mano 1 Suelte los acoplamientos...

Page 28: ...Ozono m x 0 6 gramos Conexi n 63 mm Longitud del aparato 100 cm Anchura del aparato incl reactor 75 cm N de art culo BH03752 Blue Lagoon AOP Compact Ozone UV C 75W 230V 50 60Hz N de art culo BH09752 B...

Page 29: ...deixado um espa o livre de 1 5 m necess rio para uma substitui o f cil da l mpada Q sem que para tal se tenha de desmontar o aparelho completo 1 Monte o man metro I no venturi Utilize fita vedante tef...

Page 30: ...o T por baixo do visor O visor mostra agora rSt que indica que foi seleccionado o menu de utilizador Ap s libertar o bot o T come am a piscar vez o n mero registado e o rSt no visor Um toque curto de...

Page 31: ...caso o valor no contador foi reiniciado para 4500 e pode seguidamente ser introduzido um novo valor O contador de horas alerta para a substitui o da l mpada do modo seguinte A partir do n mero 0672 o...

Page 32: ...sempre que proceda a manuten o ou desmontagem 1 Desaperte as tr s liga es e deixe escorrer a gua do aparelho 2 Desaperte as abra adeiras e retire com cuidado o aparelho dos apoios 3 Desaperte a porca...

Page 33: ...Liga o 63 mm Comprimento aparelho 100 cm Largura aparelho c reactor inclu do 75 cm Artigo n mero BH03752 Blue Lagoon AOP Compact Ozone UV C 75W 230V 50 60Hz Artigo n mero BH09752 Blue Lagoon AOP Compa...

Page 34: ...OP COMPACT OZONE UV C 75W SALTWATER 2 1 2 4 4 1 4 10 2 2 2 3 3 4 4 5 5 5 6 6 8 3 Blue Lagoon AOP Compact Ozone UV C 75W pH 30 1 5 Q 1 I 2 K N 63 50 L L N 3 M P Z 4 5 O S 6 7 R Q 8 J AOP COMPACT OZONE...

Page 35: ...OMPACT OZONE UV C 75W SALTWATER 35 UV C and Pool equipment 0 4 0 7 Blue Lagoon UV C Timer 8888 r 50H 60H UV C 4500 4500 UV C 100 4500 4500 UV C T 5 rSt T rSt 3 rSt UP dn rSt 4500 rSt T 5 4500 4500 UP...

Page 36: ...BLUE LAGOON AOP COMPACT OZONE UV C 75W AOP COMPACT OZONE UV C 75W SALTWATER dn dn T 5 5 dn 500 4500 0000 dn 10 10 4500 5 4500 0672 4 0336 2 0168 0000 Blue Lagoon AOP Compact Ozone UV C 75W 4500 U V V...

Page 37: ...0 1 2 3 U V 4 Q X 5 X 5 6 7 Y 8 9 Blue Lagoon AOP Compact Ozone UV C 75W R Q Lamp T5 Yellow base Ozone 75W 23000 2 0 6 63 100 75 BH03752 BH03752 Blue Lagoon AOP Compact Ozone UV C 75W 230V 50 60Hz BH0...

Page 38: ...ist Umwelt freundlich und hilft dazu die alte Materialen neu nutzbar zu machen Jeder andere sonstige weise von sammeln ist nicht rechtsg ltig FR INFORMATION DE RECYCLAGE Le symbole du container barre...

Page 39: ...BLUE LAGOON AOP COMPACT OZONE UV C 75W AOP COMPACT OZONE UV C 75W SALTWATER 39 UV C and Pool equipment...

Page 40: ...VGE International B V Ekkersrijt 4304 5692 DH Son The Netherlands Tel 31 0 499 461 099 info vgebv nl www vgebv com www bluelagoonuvc com Made in the Netherlands B299017...

Reviews: