FINNED TUBE HEATER - TYPE WD-H / GG-H
Page 4 of 8
NL
Sinus Jevi Electric Heating B.V.
Aambeeld 19
1671 NT Medemblik
The Netherlands
Tel. +31 (0)227-549 100
INSTALLATIoN, oPERATIoN AND
mAINTENANCE INSTRUCTIoNS
TYPE WD-H / GG-H
GB
Sinus Jevi Electric Heating B.V.
Aambeeld 19
1671 NT Medemblik
The Netherlands
Tel. +31 (0)227-549 100
INSTALLATIoN, oPERATIoN AND
mAINTENANCE INSTRUCTIoNS
TYPE WD-H / GG-H
FINNED TUBE HEATER - TYPE WD-H / GG-H
Page 5 of 8
EU Conformiteitsverklaring
Wij
Sinus Jevi Electric Heating BV
Aambeeld 19
1671 NT Medemblik
Nederland
Tel: 0227 549100
[email protected]
verklaren onder onze volledige verantwoordelijkheid dat het product
Ribbenbuiskachel
Model/ type:
WD-H / GG-H / WD-L / GG-L / WD-Z / GG-Z
is in conformiteit met de
Laag Spanningsrichtlijn 2014/35/EU (LVD) en is geverifieerd om te voldoen aan de richtlijn
2011/65/EU (RoHS) en de richtlijn 2014/30/EU (EMC).
en de volgende geharmoniseerde normen zijn hierop van toepassing:
EN 60335-1:2012; EN 60335-2-30:2010
EN 61000-6-2:2005; EN 61000-6-4:2007
Het blijft de verantwoordelijkheid van de eindgebruiker om het apparaat te installeren en te bedienen
volgens de regels en voorschriften die van toepassing zijn.
Uitgegeven in Medemblik,
Op 7 februari, 2017
J.P. Roos, Engineering Manager
Sinus Jevi Electric Heating B.V.
Introduction
In the interest of safe use please read this manual carefully and comply with the safety and operating instructions.
Safety regulations
•
The installation of the finned tube heaters must be performed by an approved installer and must be in accordance
with local regulations.
•
Please make sure there is a free airflow across the fins.
This industrial finned tube heater must be mounted on non-flammable materials only.
A minimum distance from the ceiling of 300 mm is required.
If the heater is mounted in a room that is accessible for persons, a minimum mounting height of 1.8 mtr must
be considered.
•
Do not cover the heater
•
Direct contact with the heating elements must always be prevented.
•
The heater should be safeguarded in accordance with local regulations.
•
Before opening the junction box, the heater must be cooled down and the power switched off.
Technical specifications
Voltage
230V -10/+5%
Frequency
50.... 60 Hz
Power rating
see type-plate
Relative humidity
20-80%
Ingress protection
IP65
(When there is a built-up thermostat mounted the protection is IP30)
This heater complies with the CE directives.
Cable connection by plastic cable gland M20.
The WD-H is (grey) epoxy coated, GG-H is galvanized
Application
•
Finned tube heaters are used in
normal dry
environments and in
moist
environments where
“non-flammable
material”
is stored, in compliance with IEC 60364.
•
Where there is no risk of contact, otherwise use our type WD-L/GG-L.
Installation instructions
•
Please make sure whether the local voltage is in accordance with the voltage mentioned on the type-plate of the
finned tube heater.
•
The safety regulations must be obeyed.
• The heater is suitable for fixed wiring as well as cord and plug.
• In case of fixed wiring we advise to mount a 2-pole switch, contact distance >3mm (disconnecting switch)
• The finned tube heater should be mounted horizontally.
• Earthing as specified in the low voltage regulations is mandatory.
•
Never mount the heater directly underneath a wall socket or thermostat.