De Infratemper type IHS en TA(R) zijn geschikt voor gebruik in natte, vochtige en droge situaties maar ook voor 

gebruik buitenshuis.  

Bevestiging

De Infratemper dient vast gemonteerd te worden aan de muur of plafond. Tevens dient de straler horizontaal 

gemonteerd te worden. De minimale afstand vanaf de vloer is 1,8 meter. Om de Infratemper te bevestigen dient u de 

montagebeugels te gebruiken. 

Afstandsbepaling

Zorg ervoor dat er tenminste 1 meter vrije ruimte is in de stralingsrichting. Indien de straler gemonteerd wordt aan het 

plafond dient de minimale afstand tot de muur 30 cm te zijn. Indien de straler gemonteerd wordt aan de muur dient de 

minimale afstand tot het plafond 15 cm te zijn. Zie ook de tekening hieronder. 

Ondanks de beschermklasse raden wij u aan extra voorzorgsmaatregelen te nemen wanneer u de straler buitenshuis 

monteert. 

De infratemper is niet bedoeld voor het verwarmen van lucht. De infraroodstralen zullen uitsluitend de objecten en 

personen verwarmen die zich binnen de stralen bevinden. Uiteraard zullen de objecten na verloop van tijd warmte 

afgeven aan de ruimte bij langdurig gebruik. 

Schoonmaken

Wanneer de Infratemper uitgeschakeld en afgekoeld is kan de straler schoongemaakt worden met een normaal, niet-

aggressief schoonmaakmiddel. 

The radiant heaters type IHS and TA(R) can be used in wet, moist and dry conditions as well as outdoors. 

Installation

Our radiant heaters must be permanently mounted on a wall or ceiling. It must be mounted horizontally. The electrical 

connection is located in the junction box under the name plate. The heater can be mounted outdoors (on roof or wall) 

and in bath rooms. 

Must be mounted min. 1.8 m above the floor.

 In spite of class IP44 we advise to take additional 

precautionary measures when mounted outdoors. 

Dimensioning

Make sure there is at least 1 meter of free space in the heating direction. When mounted on the ceiling the distance 

to the wall should be at least 30 cm. When mounted on the wall the distance to the ceiling should be at least 15 cm. 

Please also see the drawing below.

 

In spite of protectionclass we advise to take additional precautions measures when mounted outdoors.

The infrared rays do not heat the air but only the objects affected by the heat rays. If possible, it is recommended to 

mount several heaters so that the heat is given off from several sides. 

cleaning

Once the radiant heater is switched off and cooled down it can be cleaned with ordinary, non-aggressive detergent. 

 

 

 

 

NL

GB

min. 30 cm

min. 15 cm

min. 15 cm

min. 30 cm

min. 15 cm

min. 15 cm

Never point the radiant heater in 

direction of the roof

Never point the radiant heater in 

direction of the wall

Never place the radiant heater 

above doorways

Plaats de infraroodstraler nooit 

boven een deuropening

Richt de infraroodstraler nooit 

naar de muur

Richt de infraroodstraler nooit 

naar het plafond