background image

660-2131-0000-E

TECHNICAL SPECIFICATIONS: 

MAXIMUM LOAD PER DIMMER FOR A SINGLE 

OR A MULTI-GANG INSTALLATION:

Single installation
Multi-gang (2 units)
Multi-gang (3 units)

Protocol: Zigbee 3.0
Frequency: 

2.4 GHz

Transmission power: 

+20 dBm

Receiver sensitivity: 

-108 dBm

Neviweb® is a registered trademark of Sinopé Technologies Inc. in Canada and the United States.
Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. 
App Store is a service mark of Apple Inc., registered in the U.S. and other countries. Google Play 
and the Google Play logo are trademarks of Google Inc.

Incandescent

Lamp

600 W
500 W
400 W

600 W
500 W
400 W

150 W
150 W
150 W

Halogen

Lamp

Dimmable

LED / CFL

ADD YOUR DIMMER TO THE GT130 GATEWAY 

AND NEVIWEB

Tap the       then select "Add Device"

2

1

If you do not have an account yet, 

download the Neviweb app for iOS or 

Android to open an account and add 

your device.

Follow the steps of the Installation Wizard

3

3-year limited warranty

SINOPE TECHNOLOGIES INC. warrants the components of their products against 

defects in material and workmanship for a 3-year period from the date of purchase, 

under normal use and service, when proof of purchase of such is provided to the 

manufacturer. This warranty does not cover any transportation costs that may be 

incurred by the consumer. Nor does it cover a product that has been improperly 

installed, misused or accidentally damaged. 

The obligation of SINOPÉ TECHNOLOGIES INC., under the terms of this warranty, 

will be to supply a new unit and this releases the manufacturer from paying the 

installation costs or other secondary charges linked to replacing the unit or the 

components.

For more information, visit our Website: 

Transmitter Module IC: 5123A-GM210P / FCC QOQGM210 

This device complies with Industry Canada license exempt RSS standard(s). 

Operation is subject to the following two conditions: 

(1) this device does not cause interference, and (2) this device must accept any interference, 

including interference that may cause undesired operation of the device.

This equipment has been tested and found to comply with the limits for a Class B digital device, 

pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection 

against harmful interference in a residential installation. This equipment generates, uses and can 

radiate radio frequency energy, and if not installed and used in accordance with the instructions, 

may cause harmful interference to radio communications. However, there is no guarantee that 

interference will not occur in a particular installation. If this equipment does cause harmful 

interference to radio or television reception, which can be determined by turning the equipment 

OFF and ON, the user is encouraged to try to correct the interference by one or more of the 

following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

Operating voltage: 

120 Vac, 60 Hz

Operation temp.: 

0 °C to 40 °C (32 °F to 104 °F)

Storage: 

-20 °C to 50 °C (-4 °F to 122 °F)    

             

Standard UL: 

Conforms to ANSI/UL Std. 1472

Standard CSA: 

Certified to CAN/CSA Std. C22.2#184.1

PROVIDED CONNECTORS SPECIFICATIONS:

Stripping length: 16 mm

Wires: 22-10 AWG, Cu

Combinations: Max. 2 #12 & 2 #14, Min. 3 #20 Sol.

16 mm

DISCONNECT YOUR DIMMER FROM 

THE GT130 GATEWAY OR A 

COMPATIBLE ZIGBEE SYSTEM

CONNECT YOUR DIMMER TO THE GT130 GATEWAY OR A COMPATIBLE ZIGBEE SYSTEM

To disconnect your dimmer from the GT130 

gateway or a compatible Zigbee system, press 

the 2 buttons of the dimmer simultaneously for 

10 seconds. 

1

Connect all your dimmers the 

same way, by going to the next 

closest dimmer.

3

When all your devices are 

connected, close the 

connectivity session of 

your GT130 gateway or 

your compatible Zigbee 

gateway. 

4

Connect your dimmer to the gateway by pressing 

simultaneously the two dimmer buttons for 1 second.

The indicator flashes blue = Connecting

The indicator turns green = Connected

If the connectivity fails, the indicator will 

turn red. Refer to our Website to 

troubleshoot the unit.

 

After a few seconds, the indicator 

changes color depending on the dimmer status.

(Turned ON = blue, Turned OFF = amber)

2

Hub

2nd

1st

3rd

Initiate the connectivity session 

by pressing the RF signal button

     on the GT130 gateway. The 

indicator light will start flashing.

Compatible Zigbee gateway: 

refer to the installation guide 

for the latter.

TROUBLESHOOTING

LED bulbs flicker at low intensity

The minimum dimming light intensity can be adjusted in the 

Neviweb app to prevent the LED bulbs from flickering.

See the following link for more information: 

https://support.sinopetech.com/en/1.2.3.2.1/

Reviews: