Time adjustment (crown position 3)

In crown position 3, the motion is paused. This helps you to set the watch 
precisely. Please make sure the date changes at midnight and not at 
midday. Just move the hands forward until the date changes. Afterwards you 
attempt to set the time. We recommend moving the hands past the desired 
minute marker and then adjusting it backwards. The movement restarts as 
soon as the crown is no longer in position 3.

Quickset date and day of the week adjustment of the week (crown position 2)

Do not use this function between 9 p.m. and 3 a.m.

 Crown position 2 can  

be used to change the date and day of the week quickly and simply. To 
set the date, pull the crown to the second position and turn it 

clockwise

 

until the current date appears in the display window. To set the day of the 
week, turn the crown 

counter-clockwise

 until the desired day of the week is 

indicated. 

Please do not use the date setting function between 9 p.m. and 

3 a.m. 

Between these times, the gear wheels used for changing the date are 

engaged, and the movement could be damaged. 

Please take care to fasten the crown after making adjustments.

Day of the week/ 

date display

Summary of Contents for 144 St DIAPAL

Page 1: ...SERIES 144...

Page 2: ......

Page 3: ...UCTIONS FOR USE USING THE CHRONOGRAPH TO MEASURE TIME COMBINATION TACHYMETER AND PULSE MEASUREMENT SCALE Ar DEHUMIDIFYING TECHNOLOGY ADJUSTING THE LENGTH OF THE WATCH STRAPS TECHNICAL DETAILS ADVICE S...

Page 4: ...ratch resistance Some of our customers such as divers pilots and the German GSG 9 special police unit rely on their watches in their respective careers because their lives depend on it They all swear...

Page 5: ...hat products have to speak for themselves The basic question that we ask ourselves is which innovative technologies and materials can be employed for our craft and provide solutions for rendering our...

Page 6: ...6...

Page 7: ...example the absolutely condensation free anti reflective German Submarine Steel diving watch made possible by HYDRO Technology Other examples include a chronometer chronograph fashioned from a 22 cara...

Page 8: ...to thorough checking and fine adjustment by our master watchmakers Innovations in endurance testing The world s largest classification society for maritime safety DNV GL formerly Germanischer Lloyd Ha...

Page 9: ...e proof of the functional reliability of our watches under the toughest climatic conditions Equipped with Temperature Resistance Technology the chronograph passed the acid test at the Yukon Quest the...

Page 10: ...ries 140 and EZM 10 uses our proprietary chronograph development the SZ01 It was modelled on the Lemania 5100 calibre used in the EZM 1 One of the biggest differences between the SZ01 and the Lemania...

Page 11: ...11...

Page 12: ...e generally enough to ensure reliable functionality Under normal circumstances simply wearing the watch every day should suffice to keep the self winding mechanism wound The power reserve allows you t...

Page 13: ...wn in position 2 and turn it clockwise until the correct date appears in the date display window Please do not use the date setting function between 9 p m and 3 a m Between these times the gear wheels...

Page 14: ...the crown are generally enough to ensure reliable functionality Under normal circumstances simply wearing the watch every day should suffice to keep the self winding mechanism wound The power reserve...

Page 15: ...the week adjustment of the week crown position 2 Do not use this function between 9 p m and 3 a m Crown position 2 can be used to change the date and day of the week quickly and simply To set the dat...

Page 16: ...ed by means of buttons A and B The measurement starts when button A is pressed once Pressing this button again stops the measurement The measurement is resumed by pressing button A once more This allo...

Page 17: ...rmine an average speed using the tachymeter scale first use the chronograph to determine the length of time needed to travel one kilometre The value indicated by the second hand on the outer ring of t...

Page 18: ...inue to enjoy all the advantages of the Ar Dehumidifying Technology enhanced reliability longer intervals between maintenance Indication colours of the drying capsule Pale blue Up to 25 saturation Lig...

Page 19: ...treme diffusion reduction and a filling of protective gas guarantee that the crystal remains free from fogging even in difficult conditions Longer service intervals The sophisticated Ar Dehumidifying...

Page 20: ...ides before adjusting the length of the bracelet To ensure maximum comfort both sides of the bracelet should contain the same number of links If this is not possible the top bracelet strap above the 1...

Page 21: ...21...

Page 22: ...22...

Page 23: ...AL Technology Functionally reliable from 45 C up to 80 C Ar Dehumidifying Technology Watch Case Stainless steel bead blasted Sapphire crystal on front Case back screw fastened Transparent back made of...

Page 24: ...24...

Page 25: ...lsometer scale SINN Technology Optionally Ar Dehumidifying Technology TECHNICAL DETAILS 144 St Sa Watch Case Stainless steel bead blasted Sapphire crystal on front Case back screw fastened Transparent...

Page 26: ...26...

Page 27: ...the like Continual mechanical stress in the form of shocks and vibrations can also not only reduce water resistance but also increase wear and tear of the movement Care should therefore be taken to pr...

Page 28: ...28...

Page 29: ...are that our partners will wait until they have a sufficient number of SINN watches before they post a shipment in order to keep transport costs and customs duties to a minimum This will increase the...

Page 30: ...30 Sinn Spezialuhren GmbH 6 Auflage 6th Edition 11 2018 Technische nderungen vorbehalten Technical specifications are subject to changes...

Page 31: ...31 144 DIAPAL Nach t leuchtend Luminous 144 St Sa Nach t leuchtend Luminous...

Reviews: