Step 6:
Adjusting Width Adjustment Knob
It is important to set the width adjustment knob to the
correct setting, as this will affect the quality of your stitch.
Your serger is pre-set to the R setting at the factory.
•
Disengage upper knife by pulling knife holder to the
right and turning the knob away from you until the
knife is in a horizontal position.
•
Using Hex-Head wrench loosen width adjustment
knob by turning to the left, as shown.
•
Set the knob to the desired position by moving it
right or left, and then tighten adjustment knob by
turning the Hex-Head wrench to the right.
•
The edge of the width finger support plate will line up
with the guidelines on your throat plate as indicated
in the photo.
•
When using left and right needle with upper and
lower looper (4-thread) set width adjustment at 4.5
guideline.
•
When using left needle and upper and lower looper
(3-thread) set width adjustment at 4.5 guideline.
•
When using right needle and upper and lower looper
(3-thread) set width adjustment at 3.5 guideline.
•
When doing a 3-thread rolled hem set at R guideline.