WATER SOFTENER MANUAL

MANUALE ADDOLCITORE ACQUA

 CS3H - CS6H

4. CAUTIONS

5. IMPORTANT NOTICES

1. 

Without reading and truly understanding the contents of ths user manual, please DO NOT perform 

any operations on the control valve.

2. 

Strictly prohibit leaning position when shipping, installing and using this product. Otherwise, it will 

be damaged inside.

3. 

During regeneration time, water from tap will NOT be softened. It is NOT recommended to use 

water during regeneration otherwise, anegative effect on the regeneration result will occur.

4. 

Initial a regenerate cycle after being inactivated in a long period of time, and then turn on the tap 

for several minutes before resuming normal use.

5. 

DO NOT disconnect power during serrvice time to keep the timer run normal that controls the 

regeneration function.

6. 

If water usage or hardness of raw water dramatically increases (comparing to the normal usage), 

the frequency of regeneration should correspondingly increase.

7. 

Hot water could cause severe damage to the softener system; for water boiler and water heater 

users,  ensure  the  total-run  of  the  piping  between  the  softener  and  the  boiler  is  not  less  than  3 

meters; it is recommended to install a check valve between the filter and the boiler if unabl to meet 

the required piping length;

8. 

The input water pressure must be between 0.15 to 0.35 Mpa, no negative water pressure allowed.

9. 

No chemical allowed at the inlet and outlet connecting sectors. No excessive force which can 

damage the plastic conjunction parts should be applied by any tools. Besides the machine, spare 

part connection material doesn’t include in scope of manufacture’s warranty.

10. 

The  required  environmental  temperature  for  softner  is  33.8  -  102.2°F.  Please  protect  the 

softener from frozen.

11. 

Please set up a waterspout on the floor nearby the softener in case of any leaking accidents.

12. 

DO NOT apply any pressure on the softener; ovoid exposure to the direct sun light and radiation 

from other heating sources;

13. 

Please select regeneration salt pill as regenerant.

The controlling components are driven by an electric circuit. Some programmed parameters will 

be lost as a power outage over 8 hours, and water softener system will carry out the regeneration 

process at the incorrect time. We strongly recommend that after a power outage, user should check 

the timer or adjust it according to the appendix.

10.

 La temperatura ambiente richiesta per l’addolcitore è 33.8 - 102.2 ° F. Si prega di proteggere 

l’addolcitore dal gelo.

11.

 Si prega di istituire uno scarico sul pavimento vicino all’addolcitore in caso di eventuali incidenti 

con perdite.

12. 

Non applicare alcuna pressione sull’addolcitore; evitare l’esposizione diretta alla luce del sole e 

alle radiazioni provenienti da altre fonti di calore.

13.

 Selezionare componente di sale di rigenerazione come rigenerante.

I componenti di controllo sono azionati da un circuito elettrico.  Alcuni parametri di programmazione 

andranno  persi,  in  caso  di  assenza  di  corrente  superiore  alle  8  ore,  e  l’addolcitore  eseguirà  il 

processo di rigenerazione con tempistiche errate. Dopo una interruzione di corrente è  raccomandato 

all’utente controllare il timer o regolarlo secondo l’appendice.

4. PRECAUZIONI

5. INFORMAZIONI IMPORTANTI

Summary of Contents for CS3H

Page 1: ...UAL MANUALE ADDOLCITORE ACQUA CS3H CS6H CS6H CS3H Addolcitore acqua Rig Volume tempo Addolcitore acqua Rig Volume tempo Water softener Reg metered Time Water softener Reg metered Time Manuale di utilizzo Instruction manual ...

Page 2: ...golazioni di frequenza impostate Calcola e progetta automaticamente un piano di ciclo scientifico in base alla qualità dell acqua di alimentazione al tempo di rigenerazione ed alla frequenza di rigenerazione impostata dall utente 1 COMPONENTI 2 CARATTERISTICHE E FUNZIONALITÀ 1 COMPONENTS AUTOMATIC CONTROL VALVE Noryl pastic approved by FDA Strong corrosion resistance stainless Innovative design re...

Page 3: ...naturalmente finche l acqua non sarà saturata dallo stesso 2 CARATTERISTICHE E FUNZIONALITÀ 2 FUNCTIONS FEATURES AUTOMATIC CONTROL VALVE 24 hours control and monitorng with a timer automatically regerate the medical bed at the system s set time of regeneration according to the set regeneration frequency Automatically calculate and design more scientific cycle CYCLE PROCESS In service supply water ...

Page 4: ...ntano la resina potrebbe andare persa quando tutta l aria è stata spurgata dal serbatoio l acqua inizia a fluire costantemente dallo scarico aprire la valvola principale di alimentazione fino alla posizione completa Drenare finché l acqua di scarico non è pulita Interrompere l alimentazione idrica e lasciare l unità in piedi per cinque minuti circa per consentire la fuoriuscita dell aria rimasta i...

Page 5: ...ilizzare attrezzi che possano applicare una forza eccessiva tale da danneggiare le parti di giunzione in plastica Oltre alla macchina il materiale di collegamento per pezzi di ricambio non è compreso nella garanzia del produttore 4 PRECAUZIONI 3 OPERATION This product should be able to put in normal use right after the complete installation and a regeneration test any other operations are not nece...

Page 6: ...ld be applied by any tools Besides the machine spare part connection material doesn t include in scope of manufacture s warranty 10 The required environmental temperature for softner is 33 8 102 2 F Please protect the softener from frozen 11 Please set up a waterspout on the floor nearby the softener in case of any leaking accidents 12 DO NOT apply any pressure on the softener ovoid exposure to th...

Page 7: ... La pressione dell acqua è troppo bassa Rigenerazione impropria Resina esaurita L iniettore è otturato Inniettore collegato Perdita interna La concentrazione di salamoia è bassa Linea di salamoia collegata La linea di pressione deve essere almeno di 20 psi Resettare il timer secondo le indicazione del manuale d uso Chiama il tuo rivenditore Risciacquare il sistema per scaricare l aria Aprire il ru...

Page 8: ...oller operation Brine line plugged Leaking of bypass valve Power off Defective transformer Power outage causes inaccurate timing Air exist in the system Air exist in the system Refill time disordered Incorrect backwash controller used According to the user manual to reset the timer Call your dealer Re Backwash the system to vent air Turn on the tap to vent air Connect to constant power surce Call ...