Soft Start: 

Initial battery test to determine battery condition. If the 

battery is severely discharged charger will begin the Soft Start 
stage. Charging starts with reduced current until battery voltage 
reaches 12V. 

 

Bulk: 

Major charging stage where the battery receives the 

majority of its charge. During this stage the battery brought to 
75% - 80% of its charger. The NITRO charger delivers maximum 
current until the terminal voltage has risen to the set level of 14.5V 
for Normal battery selection and 14.2V for Gel battery selection. 

 

Absorption: 

Completes the charge up to virtually 100%

 

at a 

constant voltage of 14.5V (GEL 14.2) at +25°C. The current 
tapers off after the current reached the minimum level.   

 

Float: 

Maintenance charging at constant voltage, keeping the 

batteries at 100% charge. Normal charging mode is time-limited 
(max 10 days) while Float mode chargers indefinitely without 
damaging the battery. 
 
 

Features: 
 

 

–  Anti Spark Protection   
–  Short Circuit Protection 
–  Voltage Compensation 
–  Temperature Compensation (5-6 Temperature Settings) 
–  Battery and Charger Overheating Protection 
–  Reverse Polarity Protection   
–  Waterproof ABS Housing. Ingress Protection Rating IP65 
 

 

 
 
 

 

Summary of Contents for Nitro 3500

Page 1: ...Digital Intelligent Battery Charger OPERARATOR S MANUAL TM...

Page 2: ...Please carefully read and follow the following safety and operating instructions The Nitro is controlled by a 12 bit AD microprocessor with 4 stage charging characteristic for charging batteries autom...

Page 3: ...attery selection and 14 2V for Gel battery selection Absorption Completes the charge up to virtually 100 at a constant voltage of 14 5V GEL 14 2 at 25 C The current tapers off after the current reache...

Page 4: ...t overheating may be result To avoid risk of fire and electronic shock make sure that existing wiring and power cable are in good electrical condition Do not operate the Nitro charger if the wiring or...

Page 5: ...tery post marked NEG N For side mounted battery connections the terminals are marked Positive RED and Negative BLACK Attach charger clamps to the battery terminals ensuring a secure connection If char...

Page 6: ...the battery s voltage 6 or 12 Volts and select the battery type GEL or Standard The Nitro will now automatically assess the condition of your battery and deliver the optimum charge When charging is c...

Page 7: ...ery type GEL or Standard The Nitro will now automatically assess the condition of your battery and deliver the optimum charge When charging is completed disconnect power cable from the AC power and di...

Page 8: ...n proceed as follows Step 1 Select the desired battery voltage 6V or 12V Step 2 Select the battery type GEL or Standard GEL or STD GEL indicates a common Maintenance Free battery e g Gel Cell VRLA AGM...

Page 9: ...ttery charger will automatically maintain your battery When the AC plug is removed from the power supply connection the battery charger switches off The battery charger automatically switches back to...

Page 10: ...suitable for charging the specified batteries and should not be used to recharge non rechargeable NICAD or any other type of battery POINTS OF NOTE When not in use the battery charger must be kept at...

Page 11: ...it from being stepped on tripped over or damaged Never pull on the AC power cable to remove AC plug from the AC power outlet Pulling directly on the cord may cause damage to the cord or the plug If t...

Page 12: ...ed Sinergex dealer together with your proof of purchase The warranty is void if the product has been damaged or not used as described in this manual Warranty is void if a non authorized repair has bee...

Page 13: ...SINERGEX TECHNOLOGIES L L C USA WWW SINERGEX COM...

Reviews: