Sinclair XK117 User Manual Download Page 19

14

power-off time. Press “TIMER” button, the setting is done. If before pressing “TIM-
ER” button to finish the setting, press “MODE” button can switch to timer setting
status, liquid crystal screen will display “xx.x hour”, and “ON” and “hour” icons flash
simultaneously, then press “▲” or “▼” button to adjust the power-on time, and
press “TIMER” button again to finish the setting, the timer area will display “xx.x
hour ON/OFF”, “xx.x hour” is the time for turning off the unit in setting time, and tim-
er-on time is not displayed.

Cancel timer: after setting the timer function, press “TIMER” button, the liquid

crystal screen will not display “xx.x hour” anymore, the timer function is canceled.

Timer area: 0.5~24 hours. Each time press “▲” or “▼” button, the setting time

will increase/decrease 0.5 hour, press and hold the buttons the unit will automati-
cally increase/decrease 0.5 hour in every 0.3 second.

Note:

Under power-on status, the timer-on time is counted from the time when the unit

is turned off; under power-off status, the timer-off time is counted from the time
when the unit is turned on.

3.8

Setting of Functional Buttons

Under power-on status, press “FUNCTION” button can select to set sleep (can

be set under cooling, dry, heating modes), air exchange, silent (can be set under
auto, cooling, heating modes), health, absent (can be set under heating mode), I-
Demand (can be set under cooling mode), left & right swing, turbo fan (can be set
under cooling and heating modes), X-fan (can be set under cooling and dry mode),
auxiliary heating (can be set under heating mode), and washing remind function.
The selected functional icon will flash, then press “SWING/ENTER” button can ac-
tivate or cancel such function. Before setting, if the function has not been activated,
press “SWING/ENTER” can turn on such function; if the function is activated before
setting, press “SWING/ENTER” button can turn off such function. When the

Summary of Contents for XK117

Page 1: ...WIRED CONTOLLER XK117 USER S MANUAL EN...

Page 2: ...Original instructions IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference...

Page 3: ...ion manual is a universal manual some functions are only applicable to particular product All the illustrations and information in the instruction manual are only for reference and control interface s...

Page 4: ...Controller 6 2 3 Instruction for Liquid Crystal Display of Wired Controller 6 3 Instruction for Operation 8 3 1 Silkscreen of Buttons 8 3 2 ON OFF Setting 8 3 3 Mode Setting 10 3 4 Setting of Tempera...

Page 5: ...3 9 4 Setting of Memory Function 18 3 9 5 Switch between Fahrenheit and Degree Celsius 18 3 9 6 Inquiry of Ambient Temperature 18 4 Display of Errors 19...

Page 6: ...1 1 Installation 1 1 Dimension and Component of Wired Controller Figure 1 1 Dimension of Wired Controller Unit mm Figure 1 2 Components of Wired Controller...

Page 7: ...r with the same model and cause malfunction 4 Before installation please cut off the power supply of strong current wire inside the wall it is not allowed to install under electrified status 5 In orde...

Page 8: ...ation please cut off the power supply of indoor unit live working during installation is not allowed 2 Pull out the 2 core STP inside the wall from the installing hole thread the wire through the conn...

Page 9: ...4 5 Buckle the panel of wired controller with the soleplate then the installation is finished Figure 1 3 Sketch Map for Installation of Wired Controller...

Page 10: ...f Wired Controller Disassembly for wired controller is as below Figure 1 4 Sketch Map for Disassembly of Wired Controller 2 Introduction to Display 2 1 Outline of Wired Controller Figure 2 1 Outline o...

Page 11: ...2 3 1 Instruction for Liquid Crystal Display of Wired Controller No Display Instruction of Display 1 Auto Automatic mode under auto mode the indoor unit will select its operating mode according to the...

Page 12: ...wn swing Display when up and down swing function is set 15 Slave wired controller Icon of slave wired controller it will display when slave wired controller is set 16 Fan speed The fan speed set curre...

Page 13: ...tus 3 Instruction for Operation 3 1 Silkscreen of Buttons Figure 3 1 Silkscreen of Buttons 3 2 ON OFF Setting Press ON OFF button to turn on the air conditioner then the wired controller will display...

Page 14: ...9 Figure 3 2 ON Status Figure 3 3 OFF Status...

Page 15: ...tting Note Under auto mode if the unit conducts auto cooling then and turn on if the unit conducts auto heating then and turn on 3 4 Setting of Temperature Under power on status press or button the se...

Page 16: ...11 Temperature setting range under cooling dry fan and heating mode is 16 30 The setting temperature cannot be adjusted under auto mode Figure 3 5 Setting of Temperature...

Page 17: ...3 6 Setting of Fan Speed Note 1 Under dry mode the fan speed will automatically set as low speed and the fan speed cannot be adjusted 2 Under fan and auto mode turbo speed cannot be set 3 6 Setting o...

Page 18: ...and timer function has not been set press TIMER button the liquid crystal screen will display xx x hour and ON and hour icons flash simultaneously then press or button to adjust the power on time Pres...

Page 19: ...crease 0 5 hour in every 0 3 second Note Under power on status the timer on time is counted from the time when the unit is turned off under power off status the timer off time is counted from the time...

Page 20: ...re as below 1 the unit runs for 60 minutes fresh air valve opens for 6 minutes 2 the unit runs for 60 minutes fresh air valve opens for 12 minutes 3 the unit runs for 60 minutes fresh air valve opens...

Page 21: ...he current accumula tive time then CLEAN icon will stop flashing if the time after adjustment is less than the current accumulative time then CLEAN icon will continue to flash The only method for canc...

Page 22: ...n are displayed the SAVE character or icon flashes the temper ature area displays the upper limit and lower limit temperature press or button can set the limit temperature setting range is 16 30 Press...

Page 23: ...emory function has not been set when the unit is re energized after power failure the unit is power off status If the memory function is set in wired controller when the wired controller is re energiz...

Page 24: ...Display of Errors When error occurs in the system temperature display area in liquid crystal panel will display error code when multiple errors occur simultaneously it will circularly display error c...

Page 25: ...4 1 Error Code List Error Code Error E1 Compressor high pressure protection E2 Indoor anti freeze protection E3 Compressor low pressure protection refrigerant lack protec tion refrigerant collection m...

Page 26: ...5 Wired controller temperature sensor error C5 IDU jumper cap error EE IDU or ODU memory chip error PF Electric box sensor error H3 Compressor overload protection H4 Overload H5 IPM protection H6 DC f...

Page 27: ...tection PA AC current protection Pc Driver current error Pd Sensor connection protection PE Temperature drift protection PL Bus low voltage protection PH Bus high voltage protection PU Charging loop e...

Page 28: ...ces you are making an important contribution to the protection of our environment Please ask your local council where your nearest disposal station is located In case of quality problem or other pleas...

Reviews: