6
1 - GENERAL INSTRUCTIONS
HYDRAULIC SYSTEM
ELETTRIC SYSTEM
Components
Selection and installation of system
components must be carry out by
installer.
Water quality
The water quality is determined by the
following factors, avoid therefore:
- Inorganic salts
- pH
- Biological load (seaweeds etc)
- Suspended solids
- Dissolved oxygen
Water with inadequate characteristics
can cause:
- pressure drop increase
- energy efficiency decrease
- corrosive symptom increase
Risk of freeze
If the unit or the relative water
connections can be subject to
temperatures close to 0°C adopt
measures for prevent risk of freeze.
The appliance is intended to be
permanently connected to the water
mains and not connected by a hose-set .
The water may drip from the discharge
pipe of the pressure-relief device and
that this pipe must be left open to the
atmosphere.
The pressure-relief device is to be
operated regularly to remove lime
deposits and to verify that is not blocked.
A discharge pipe connected to the
pressure-relief device is to be installed in
a continuously downward direction and
in a frost-free environment.
General
The characteristics of the electrical lines
must be determined by specialized
personnel able to design electrical
installations; moreover, the lines must be
in conformity with regulations in force.
Operate in compliance with safety
regulations in force .
This unit is required reliable earthing
before usage, otherwise might cause
death or injury.
If you can't make sure that your house
power supply is earthed well, please
don't install the unit if it does not in
conformity with regulations in force.
The power supply should be an
independent circuit with rated voltage.
Power supply circuit should be earthed
effectively.
Do not use water pipes to earthing
connection of the unit
Use single protection devices : gloves,
glasses ecc.
The power cables and the protection
cable section must be defined in
accordance with the characteristics of the
protections adopted. The serial number
label reports the unit specific electrical
data, included any electrical accessories.
Connection
All electrical operations should be
performed by trained personnel having
the necessary requirements by the
regulations in force and being informed
about the risks relevant to these
activities. Refer to the unit electrical
diagram (the number of the diagram is
heating, within limits defined in the
technical bulletin and on this manual.
Any use other than intended does not
involve the manufacturer in any
commitment or obligation.
This unit is required reliable earthing
before usage, otherwise might cause
death or injury.
Summary of Contents for SWH-190IRE
Page 57: ...57...
Page 58: ...58...
Page 59: ...59...
Page 60: ...60...
Page 61: ...62 NOTE...
Page 62: ...63 NOTE...
Page 63: ...SWH 190IRE SWH 300IRE WATER HEATERS PARTS GUIDE H E A T P U M P S SWH 190IRES SWH 300IRES...
Page 64: ...SWH 190IRE...
Page 65: ......
Page 67: ...SWH 300IRE...
Page 68: ......
Page 70: ...SWH 190IRES...
Page 71: ......
Page 73: ...SWH 300IRES...
Page 74: ......