Sinclair SIH-09BIT Series User Manual Download Page 11

button

button

button

button

Under cool or heat mode, press this button to turn 

to quick cool or quick heat mode. "      " icon is 

displayed on remote controller. Press this button 

again to exit turbo function and "    " icon will 

disappear.

If start this function, the unit will run at super-high 

fan speed to cool or heat quickly so that the ambi

-

ent temperature approaches the preset tempera

-

ture as soon as possible.    

Press this button can select left & right swing angle. 

Fan blow angle can be selected circularly as below:

● 

● 

● 

● 

Press "▲" or "▼" button once increase or dec- 

rease set temperature 1°C(°F). Holding "▲" or "▼" 

button, 2s later, set temperature on remote control- 

ler will change quickly. On releasing button after 

setting is finished, temperature indicator on indoor 

unit will change accordingly. 

When setting TIMER ON, TIMER OFF or CLOCK, 

press "▲" or "▼" button to adjust time. (Refer to 

CLOCK, TIMER ON, TIMER OFF buttons).

“                 " may not be available. When air condi

-

tioner receives this signal, the air conditioner will blow 
fan automatically.
Press this button continuously for more than 2s, the 
main unit will swing back and forth from up to down, 
and then loosen the button, the unit present position 
of guide louver will be kept immediately.
Under up and down swing mode, when the status is 
switched from off to     , if press this button again 2s 
later,      status will switch to off status directly; if 
press this button again within 2s, the change of swing 
status will also depend on the circulation sequence 
stated above.     

● 

● 

● 

When selecting "     ", air conditioner is blowing 

fan automatically. Horizontal louver will automat

-

ically swing up & down at maximum angle.

When selecting "                          ", air condition

-

er is blowing fan at fixed position. Horizontal 

louver will stop at the fixed position.

When selecting "                  ", air conditioner is 

blowing fan at fixed angle. Horizontal louver will 

send air at the fixed angle.

Hold "     "button above 2s to set your required 

swing angle. When reaching your required 

angle, release the button.          

no display

(horizontal louvers 

stops at current position)

button

Press this button can select up & down swing angle. 

Fan blow angle can be selected circularly as below:

N

OTE

N

OTE

no display

(st

ops

 

a

current po

si

tion)

● 

 2s later,        status will switch to off status directly; if 
press this button again within 2s, the change of swing 
status will also depend on the circulation sequence stat- 
ed above.
The function is only available for some models.

Press this button, can select Sleep 1 (      ), 

Sleep 2 (     ), Sleep 3 (     ) and cancel the 

Sleep, circulate between these, after electrified,

Sleep Cancel is defaulted.

Sleep 1 is Sleep mode 1, in Cool modes; sleep

status after run for one hour, the main unit setting

temperature will increase 1 , two hours, setting

1

2

3

Having set X-FAN function on: After turning off the 
unit by pressing "    " button indoor fan will continue 
running for a few minutes. at low speed. In this per- 
iod, Hold fan speed button for 2s to stop indoor fan 
directly.
Having set X-FAN function off: After turning off the 
unit by pressing "    " button, the complete unit will 
be off directly.

● 

● 

● 

● 

Press this button continuously more than 2s, the main 
unit will swing back and forth from left to right, and 
then loosen the button, the unit will stop swinging and 
present position of guide louver will be kept immedi

-

ately.
Under left and right swing mode, when the status is 
switched from off to         , if press this button again 

Summary of Contents for SIH-09BIT Series

Page 1: ...Ver TERREL SERIES SIH 09BITx SIH 13BITx SIH 18BITx SIH 24BITx SOH 09BIT SOH 13BIT SOH 18BIT SOH 24BIT EN User Manual 01 06 03 2021...

Page 2: ...R I G I N A L I N S T R U C T I O N S I M P O R TA N T N O T E Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future referen...

Page 3: ...zuladen geben Sie bitte den Modellnamen f r diesen Link ein Term k k zik nyv nek let lt s hez rja be a modell megnevez s t az al bbi linkre Za prenos navodil za uporabo tega izdelka vnesite ime modela...

Page 4: ...reasons This symbol indicates the possibility of death or serious injury This symbol indicates the possibility of injury or damage to property Indicates important but not hazard related information u...

Page 5: ...y the manufacturer its ser vice agent or similarly qua lified persons in order to avoid a hazard Do not connect air condi tioner to multi purpose soc ket Otherwise it may cau se fire hazard Do disconn...

Page 6: ...It may cause mal function Do not step on top panel of outdoor unit or put heavy objects It may cause dam age or personal injury When below phenomenon occurs please turn off air conditioner and disconn...

Page 7: ...ease use aux button to turn on or turn off the air conditioner The operation in details is as below As shown in the figure open panel and press aux button to turn off the air conditioner When the air...

Page 8: ...Parts name Outdoor Unit NOTE Actual product may be different from above graphics please refer to actual product air inlet air outlet...

Page 9: ...temp Sleep mode Clock Health mode I feel Quiet TIMER ON TIMER OFF Auto mode Cool mode Dry mode Fan mode Left right swing Up down swing Child lock Send signal Turbo mode Heat mode Operation mode Set fa...

Page 10: ...ve turn ed off the unit After energization X FAN OFF is defaulted X FAN is not available in auto fan or heat mode This function indicates that moisture on evaporator of indoor unit will be blowed afte...

Page 11: ...omat ically swing up down at maximum angle When selecting air condition er is blowing fan at xed position Horizontal louver will stop at the xed position When selecting air conditioner is blowing fan...

Page 12: ...perature In Heat mode sleep status after run for one hour the setting tem perature will decrease 1 two hours setting temperature will decrease 2 then the unit will run at this setting temperature Slee...

Page 13: ...tus Operation for TIMER ON TIMER OFF is the same Press this button to set clock time icon on remote controller will blink Press or button within 5s to set clock time Each pressing of or button clock t...

Page 14: ...emperature when turning on the unit There is no display in the remote control ler Only for the models whose indoor unit has dual 8 dis play When selecting displaying of indoor or outdoor ambi ent temp...

Page 15: ...ong the arrow direction Replace two 7 AAA 1 5V dry batteries and make sure the position of polar and polar are correct Reinstall the cover of battery box 2 1 3 battery remove reinstall Cover of batter...

Page 16: ...et for outdoor unit is damaged or corroded If yes please contact dealer The filter should be cleaned every three months If there is much dust in the operation environme After removing the filter do no...

Page 17: ...and or contraction of panel or other parts due to the change of temp erature In order to prevent blowing out cold air indoor unit will be started after delaying for several minutes which is a normal p...

Page 18: ...W1F 7LD Great Britain www sinclair world com This product was manufactured in China Made in China R E P R E S E N TAT I V E SINCLAIR Global Group s r o Purkynova 45 612 00 Brno Czech Republic T E C H...

Page 19: ...zuladen geben Sie bitte den Modellnamen f r diesen Link ein Term k k zik nyv nek let lt s hez rja be a modell megnevez s t az al bbi linkre Za prenos navodil za uporabo tega izdelka vnesite ime modela...

Page 20: ......