![Sinclair MS-H07AIC PT Service Manual Download Page 35](http://html1.mh-extra.com/html/sinclair/ms-h07aic-pt/ms-h07aic-pt_service-manual_1280188035.webp)
,QVWDOODWLRQDQG0DLQWHQDQFH
6HUYLFH0DQXDO
(0DOIXQFWLRQ
Communication malfunction of
some indoor units
Does the
broken-down indoor
unit resume normal?
De-energize the unit and check
if the connecting wire of indoor
and outdoor unit and wiring of
electric box are correct.
Is wire connected
correctly
˛
Connect wires
according to the
wiring diagram
De-energize the unit. Change the communication cable
of indoor units. Energize the unit and wait for 3 min
Yes
No
Replace mainboard
of outdoor unit
Replace the broken-down
mainboard of the indoor unit
No
Yes
End
Is malfunction
removed
˛
Yes
No