Under the unit is under the “Off” status, it is available to switch over the defrosting
mode 1 and defrosting mode 2 by pressing the “Mode” and “Blow” buttons
simultaneously.
8 Performance Parameters
Rated Working Conditions of the Air Conditioning Unit
Table 18 Working Temperature Range
Indoor side state
Outdoor side state
Dry bulb temp.
℃
Wet bulb
temp.
℃
Dry bulb
temp.
℃
Wet bulb
temp.
℃
Rated Cooling
27
19
35
24
Max. cooling
32
23
48
26
Min. cooling
21
15
18
—
Rated Heating
20
15
7
6
Max. heating
27
—
24
18
Min. heating
20
15
-
15
-
16
Notes
:
①
.
The heating/cooling capacity and noise listed below are all measured before
the shipment.
②
.
All parameters listed above are measured under the standard working
conditions. If there is any change, the parameters marked on the nameplate
always prevail.
③
.
The heating capacity of the indoor unit just involves that of the heat pump but
apart from that of the auxiliary electric heater.