Wired Controller XK19
10
When the Turbo function is activated, press Function to enter the Turbo setting interface and then press
Enter/Cancel to cancel this function.
Turbo function setting is as shown in Fig.14.
Fig.14 Turbo Setting
Notes:
① .
When the Turbo function is activated, if the difference between the room temperature and set
temperature is at or below 2
℃
(detected in successive 1 min.), the Turbo function will be automatically
deactivated.
② .
Turbo function is unavailable in the Dry and Fan mode. And the Turbo function is off after power
failure and then power recovery. If Quiet function is on, Turbo function will be canceled subsequently.
3.9 Save Setting
Save: Energy saving which will result the air conditioner runs in smaller temperature range is realized by
setting lower limited value in the Cooling or Dry mode and upper limited value in the Heating mode.
Save Setting for Cooling:
Under the “On” state and in the Cooling or Dry mode of the unit, press Function to enter the Save setting
interface and then press ▲or ▼ to adjust the lower limited value in the Cooling mode. After that, press Enter/
Cancel to activate the Save function. The initial lower limited value in the Cooling mode is 26
℃
.
When the Save function is activated, press Function to enter the Save setting interface and then press
Enter/cancel to cancel this function.
The Save setting for cooling is shown in the Fig.15