Sinclair CFO-20N Operation Manual Download Page 9

 

- 8 -

LONG TERM STORAGE 

When you do not use the unit for a long period, we suggest you to take following steps to store the 
unit in a good condition: 
 

„

  Make sure there is no water left in the water tank and take off the draining hose. 

„

  Take off the power cord and plug and warp them well. 

Clean the unit and packed it well to keep it from dust. 
 
 

ELECTRIC SCHEMATIC DIAGRAM 

 

 

TECHNICAL SPECIFICATION 

 

Model CFO-20N 

Rated Voltage 

220–240 V~ 

Rated Frequency 

50 Hz 

Rated Power 

330 W (max. 480 W) 

Moisture Removal (at 30 °C, 27,1 °C) 

20 liters/day 

Operating Temperature 

5–35 °C 

Refrigerant R134a 

(0,20kg) 

Sound power level 

55 dB(A) 

Weight 

14,5 kg  

Tank capacity 

4,0 liters 

 
 
 
 
 
 
 
 

BK 
BN 
BU 
Fan motor 
Humididy sensor 
PE 
Power 
Room tem. sensor 
Tube tem. sensor 
Water switch 
YEGN 

 
Fuse 3,15 A 

Summary of Contents for CFO-20N

Page 1: ...Operation manual CFO 20N Dehumidifier...

Page 2: ...cling 4 The appliance shall not be installed in the laundry 5 The appliance shall be installed in accordance with national wiring regulations and must be positioned so that the plug is accessible CONT...

Page 3: ...le it is plugged in or in use Do not place objects on the product or allow objects to obstruct the inlet or outlet openings or operate in close proximity to walls or curtains etc The use of attachment...

Page 4: ...tual 5 accuracy room humidity level Controls the fan speed moisture removal When the humidity has been reduced and quiet operation is 3 Control type 1 This unit has 3 min lag due to the device for pro...

Page 5: ...become slightly warmer as the dehumidifier operates Automatic Defrost Choosing a Location NOTE The dehumidifier has rollers to aid placement but it should only be rolled on smooth flat surfaces Do not...

Page 6: ...not remove the bucket while the unit is in operation or it has just stopped Otherwise it may cause some water to drip from the draining pan The bucket must be in place and securely seated for the dehu...

Page 7: ...To replace NOTE The bucket must be in place and securely seatedfor the dehumidifier to operate Air Filter The air filter should be checked and cleaned at least every 250 hours of operation or more oft...

Page 8: ...re laden The dryer should be vented to the outside air into the room Room temperature Moisture removal is best at higher room temperatures is too low Lower room temperatureswill reduce the moisture re...

Page 9: ...m well Clean the unit and packed it well to keep it from dust ELECTRIC SCHEMATIC DIAGRAM TECHNICAL SPECIFICATION Model CFO 20N Rated Voltage 220 240 V Rated Frequency 50 Hz Rated Power 330 W max 480 W...

Page 10: ...efrigerant please see the unit label Hermetically sealed system The value GWP 1430 GWP Global Warming Potential In case of quality problem or other please contact your local supplier or authorized ser...

Reviews: