Sinclair ASH-09AIE2 User Manual Download Page 14

  

1.Remove the battery cover plate from the rear of the remote controller.

(As shown in the figure)

2.Take out the old batteries. 
3.Insert two new AAA1.5V dry batteries, and pay attention to the polarity. 

4. Reinstall the battery cover plate. 

When replacing the batteries, do not use old or different types of batteries,

If the remote controller will not be used for a long time, please 

otherwise, it may cause malfunction.

remove batteries to prevent batteries from leaking. 

The operation should be performed in its receiving range.
It should be kept 1m away from the TV set or stereo sound sets.
If the remote controller does not operate normally, please take the 

batteries out and reinsert them after 30 seconds.If it still can't operate properly,   

Notes:

replace the batteries.

Operation of Remote Controller

Sketch map for 

replacing batteries

Replacement of Batteries

Press "+ " and  "-" buttons simultaneously to lock or unlock the keypad. If the remote 
controller is locked,          is   displayed. In this case, pressing any button,       blinks 

 

three times.

At unit OFF, press 

"

MODE

and

 " - " 

buttons simultaneously to switch between     and     . 

 

Combination of "+" and "-" buttons: About lock

17

About Back-lighting Function

About HEALTH function(COLD PLASMA)

Turn on the unit, start up the fan (Breezing and X-FAN are excluded) and press HEATLTH

button on remote controller to start health function (If there is not HEALTH button on 

remote controller, the unit defaults health function ON. )

21

Combination of "MODE " and "-" buttons :

18 

About switch between Fahrenheit and centigrade

Press “TEMP” and “CLOCK” simultaneously in COOL mode to start energy-saving function.
Nixie tube on the remote controller displays “SE”. Repeat the operation to quit the function.  

Combination of " TEMP " and "CLOCK" buttons : About Energy-saving Function

19

Press “TEMP” and “CLOCK” simultaneously in HEAT mode to start 

The unit lights for 4s when energizing for the first time, and 3s for later press.

8

 

Heating Function

.

Nixie tube on the remote controller displays “     ” and a selected temperature of “

8

” 

(46     if 

Fahrenheit is adopted). Repeat the operation to quit the function.

 

Combination of " TEMP " and "CLOCK" buttons : About  8

 

Heating Function

20

2

1

3

4

12

Summary of Contents for ASH-09AIE2

Page 1: ...USER S MANUAL ELEMENT 2 SERIES indoor unit ASH 09AIE2 ASH 12AIE2 ASH 18AIE2 ASH 24AIE2 ...

Page 2: ... Original instruction ...

Page 3: ... appliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Do not wash the air conditioner with water to avoid electri...

Page 4: ...damage 2 Precautions WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not spill water on the remote controller otherwise the electric shock or damage Please contact dealer when you need to repair air conditioner Do not repair air conditioner by yourself It may cause obje...

Page 5: ...cables before using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket Properly connect the live wire neutral wire and any work related to electricity and safety Be sure to cut off the power supply before proceeding Including an circuit break with suitable capacity plea...

Page 6: ...onnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only 4 Precautions WARNING wire which can t be used for other purposes The grounding resistance should comply with national electric safety regulations The air conditioner is the first class electric appliance It keep the interconnection cable away from the copper tube The temperature of refri...

Page 7: ...st be installed in the line For the air conditioner without plug an circuit break Select a location which is out of reach for children and For the air conditioner with plug the plug should be Working temperature range 5 Indoor side DB WB C Outdoor side DB WB C Maximum cooling 32 23 43 26 Maximum heating 27 24 18 The operating temperature range outdoor temperature for cooling is 15 43 The operating...

Page 8: ...r air outlet heating indicator temp indicator cooling indicator power indicator receiver window aux button drying indicator display remote controller Actual product may be different from above graphics please refer to actual products NOTICE ON OF F MOD E FAN SW I NG I FEE L SLEE P TE M P TI MER ON CLOCK T OF F IMER TURBO LIGHT X FAN F C H O U R ONOFF 6 ...

Page 9: ...re setting Press it to decrease temperature setting FAN Press it set swing angle TIMER ON SWING TIMER OFF CLOCK X FAN TEMP TURBO SLEEP LIGHT Press it to set fan speed Press it to set auto on timer Press it to set auto off timer Press it set clock 1 7 Press it to set HEALTH or AIR function 8 I FEEL 4 3 2 5 6 11 13 12 16 10 14 9 15 Operation of Remote Controller 3 15 5 4 14 7 16 13 12 9 8 11 10 2 1 ...

Page 10: ... pressed current operation mode icon AUTO COOL DRY FAN or HEAT only for heat pump models will show 17 is displayed when pressing the up down swing down button Press this button again to clear the display 21 Up down swing icon After pressing TIMER button ON or OFF will blink This area will show the set time SET TIME display 23 Pressing TEMP button set temperature ambient temperature outdoor ambient...

Page 11: ... button again to clear the display TURBO icon 28 is displayed when Pressing TEMP and CLOCK simulta neously in Heat mode 8 Heating icon 31 is displayed when pressing the X FAN button Press this button again to clear the display X FAN icon 27 Press FAN button to select the desired fan speed setting AUTO Low Med High Your selection will be displayed in the LCD windows except the AUTO fan speed FAN SP...

Page 12: ... ON OFF MODE This button is used for setting Fan Speed in the sequence that goes from AUTO to then back to Auto FAN 1 4 3 2 5 Operation of Remote Controller Press this button to turn on the unit Press this button again to turn off the unit Press this button to decrease set temperature Holding it down above 2 seconds rapidly decreases set temperature In AUTO mode set temperature is not adjustable P...

Page 13: ... then by 10 minutes every 0 5 second During blinking after setting press CLOCK button again to confirm the setting and then 12 will be constantly displayed TIMER ON TIMER OFF 11 13 TURBO 10 14 Operation of Remote Controller TEMP Press this button to initiate the auto ON timer To cancel the auto timer program simply press this button again After press of this button disappears and ON blinks 00 00 i...

Page 14: ... In this case pressing any button blinks three times At unit OFF press MODE and buttons simultaneously to switch between and Combination of and buttons About lock 17 About Back lighting Function About HEALTH function COLD PLASMA Turn on the unit start up the fan Breezing and X FAN are excluded and press HEATLTH button on remote controller to start health function If there is not HEALTH button on r...

Page 15: ...rface of indoor unit When the surface of indoor unit is dirty it is recommended to use a soft dry cloth or wet cloth to wipe it NOTICE Do not remove the panel when cleaning it If remote controller is lost or damaged please use auxiliary button to turn on or turn off the air conditioner The operation in details are as below conditioner When the air conditioner is turned on it will operate under aut...

Page 16: ...n panel Pull out the panel to a certain Use dust catcher or water to the water below 45 to clean it and then put it in a shady and cool place to dry panel cover tightly operation environment clean frequency can be increased WARNING 14 ...

Page 17: ...rface of indoor unit When the surface of indoor unit is dirty it is recommended to use a soft dry cloth or wet cloth to wipe it NOTICE Do not remove the panel when cleaning it If remote controller is lost or damaged please use auxiliary button to turn on or turn off the air conditioner The operation in details are as below conditioner When the air conditioner is turned on it will operate under aut...

Page 18: ...m Pull out the plug Reinsert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re ceiving window on indoor unit Check the batteries If the power of batteries is too low please replace them Take the remote controller close to indoor unit Turn off the fluoresent lamp and then try it again...

Page 19: ...or temperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set temper ature can t be adjusted Unit is operating under auto mode Temperature can t be adju sted under auto mode Please switch the operation mode if you need to adjust temperature Your required temperatur...

Page 20: ...it again Outdoor unit has vapor Heating mode is turned on During defrosting under he ating mode it may generate vapor which is a normal phenomenon Water flowing noise Air conditioner is turned on or turned off just now The noise is the sound of refrigerant flowing inside the unit which is a normal phenomenon Cracking noise Air conditioner is turned on or turned off just now This is the sound of fr...

Page 21: ...ced please take off the old for the new PCB Check if indoor room temperature sensor is connected properly Check if the evaporator temperature is connected properly H6 Indoor fan block Replace the fan motor or the indoor board if disabled Check if the terminal of the indoor motor is conne cted properly E5 E8 U8 Please contact qualified professionals for service Please contact qualified professional...

Page 22: ...Installation dimension diagram At least 250cm At least 15cm At least 300cm Space to the ceiling Space to the obstruction At least 15cm At least 15cm Space to the wall Space to the wall 20 ...

Page 23: ...e installed 2 5m 7 Don t install the indoor unit right above the electric appliance Indoor unit 1 The place with strong heat sources 8 Please try your best to keep way from fluorescent lamp or volatile objects spread in the air 2 The place with high frequency devices such as welding machine medical equipment 3 The place near coast area 4 The place with oil or fumes in the air 5 The place with sulf...

Page 24: ...grounding with specialized grounding device by a professional Please make sure it is always grounded effectively otherwise it may cause electric shock 2 The yellow green wire in air conditioner is grounding wire which can t be used for other purposes 3 The grounding resistance should comply with national electric safety regulations 4 The appliance must be positioned so that the plug is accessible ...

Page 25: ...piping hole 2 Open a piping hole with the diameter of Φ55 70 on the selected outlet pipe position In order to drain smoothly slant the piping hole on the wall slightly downward to the outdoor side with the gradient of 5 10 Left Wall Φ70 Right Mark in the middle of it Level meter Rear piping hole Wall Space to the wall above 150mm Space to the wall above 150mm Φ70 Rear piping hole Left Wall Φ55 Rig...

Page 26: ...t the pipe from left or right please cut off the corresponding hole on the bottom case cut off the hole left right 1 The pipe can be led out in the direction of right rear right left or rear left left rear left right rear right Step four outlet pipe Installation of indoor unit union nut pipe joint pipe Note Pay attention to dust prevention and take relevant safety measures when opening the hole Th...

Page 27: ...n the wiring cover and then take wiring cover screw panel Step seven connect wire of indoor unit 4 Wrap the indoor pipe and joint of con then wrap it with tape Step six install drain hose Installation of indoor unit torque wrench open end wrench indoor pipe pipe union nut Hex nut diameter Tightening torque N m Φ 6 Φ 9 52 Φ 12 Φ 16 Φ 19 30 40 45 55 60 65 70 75 15 20 indoor unit 2 Bind the joint wit...

Page 28: ...n the line The air switch should be all pole parting and the contact parting distance should be more than 3mm power connection wire cable cross hole 2 Make the power connection wire go through the cable cross hole at the back of indoor unit and then pull it out from the front side 3 Remove the wire clip connect the power connection wire to the wiring terminal according to the color tighten the scr...

Page 29: ...rately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom drain hose band connection pipe indoor power cord Step nine hang the indoor unit 1 Put the bound pipes in the wall pipe and then make them pass through the wall hole 2 Hang the indoor unit on the wall mounting frame 3 Stuff the gap between pipes and wall hole with sealing...

Page 30: ...it grounded securely It may cause electric leakage Does the power cord follow the speci fication It may cause malfunction or damaging the parts Is there any obstruction in the air inlet and outlet It may cause insufficient cooling heating capacity The dust and sundries caused during installation are removed It may cause malfunction or damaging the parts The gas valve and liquid valve of connection...

Page 31: ...refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging amount per meter Cooling capacity Cooling capacity 5000Btu h 1465W 24000Btu h 7032W 7000Btu h 2051W 28000Btu h 8204W 9000Btu h 2637W 36000Btu h 10548W 12000Btu h 3516W 42000Btu h 12...

Page 32: ...connection pipe Liquid pipe mm Gas pipe mm Φ6 Φ6 or Φ9 52 Φ9 52 or Φ12 Φ12 Φ16 Φ19 Φ22 2 Φ16 or Φ19 Φ19 or Φ22 2 Φ25 4 or Φ31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350 120 120 50 20 Outdoor unit throttle Configuration of connection pipe 30 ...

Page 33: ...itable insulating pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe union pipe pipe E Expand the port Expand the port with expander Note A is different according to the diameter please refer to the sheet below expander hard mold pipe F Inspection Check the quality of expanding port If there is any blemish expand the p...

Page 34: ...32 ELECTRIC SCHEMATIC DIAGRAM ASH 09AIE2 indoor ASH 12AIE2 indoor ASH 18AIE2 indoor ASH 24AIE2 indoor ...

Page 35: ...33 RATING LABEL ...

Page 36: ...34 ENERGY LABEL ...

Page 37: ...is located INFORMATION CONCERNING USED REFRIGERANT MEDIUM This unit is containing fluorinated gases included in the Kyoto protocol The maintanance and the liquidation must be carried out by qualified personel Type of refrigerant R410A The composition of the cooling medium R410A 50 HFC 32 50 HFC 125 The quantity of the refrigerant please see the unit label The value GWP 2088 GWP Global Warming Pote...

Reviews: