background image

                       USER'S MANUAL       

                   AMC-11AN

, AMC-14AN

 L

O

CAL AIR CONDITIONER 

Summary of Contents for AMC-11AN

Page 1: ...USER S MANUAL AMC 11AN AMC 14AN LOCAL AIR CONDITIONER ...

Page 2: ...k you for showing confidence in our product We hope you enjoy a pleasant room climate with your air conditioner Original instructions EASY TO OPERATE AND TO EASY TO MOVE AROUND 9 The unit can be moved easily on rollers from room to room 9 The air quantity can be adjusted via up to three ventilation levels 9 The air flow can be very strong and reach up to 5 or 6 metres 9 Installation by a specialis...

Page 3: ...he unit 6 Plug the power plug into a socket Never pull the plug out of the socket with force using the connection line This can damage the power cable 7 Since the unit emits hot air please observe a sufficient minimum safety distance to each wall Fig 1 8 Despite the splash water protection you should not operate the unit in moist areas such as e g swimming baths or similar areas 9 The colour of th...

Page 4: ...inutes after switching off the unit before switching it back on to ensure the compressor is not damaged 7 The compressor of the unit has a power demand of at least 7 amps Do not use any extension cable with this unit 8 The unit is designed for the cooling heating and dehumidification of inside rooms Other use is excluded 9 If the power cable is damaged it must be replaced by a qualified specialist...

Page 5: ...vely up to a minimum temperature of 15 C 5 LED DISPLAY The display shows the required target temperature By pressing the TEMP or TEMP switch the required target temperature is briefly displayed On pressing the TIMER switch the number of hours is briefly shown until activation or deactivation After each manual setting the display automatically shows the required target temperature In the dehumidifi...

Page 6: ...ich the unit is to switch off ii After the flashing of the number of hours on the LED has stopped you can select the required function cooling heating dehumidification and the required temperature iii When the set number of hours has expired the unit switches on automatically If you press the POWER switch before the time has expired the Timer programming is deleted and the unit switches off 8 SLEE...

Page 7: ...ir hose This can be executed e g via a tilted window a door or wall aperture Make sure that no warm outside air can enter the room For effective cooling we recommend our selection of various accessories which reduce or prevent entry of warm air into the room Place the function to COOLING Set the target temperature using the temperature control The settable temperature range is between 17 and 30 de...

Page 8: ...make sure that the condesnation water outlet is closed with the rubber cap during operation In such a case proceed analogously to the emptying of the water tank in the cooling function 9 The heating function of the unit must not be operated at a room temperature of more than 23 C or less than 7 C The unit can also be operated with heating function if the outside temperature is lower than 7 C Howev...

Page 9: ... remote control The Comfort Control Kit set is additional accessories It is possible to buy it at the seller or supplier After switching on or over the ventilator operates but the compressor only starts after the control lamp has flashed for three minutes Cooling effect may require a further 10 minutes Further information is available under the item Troubleshooting DEHUMIDIFICATION Humidity is ext...

Page 10: ...e unit WITHOUT the extract air hose No To achieve temperature adjustments surplus heat or coldness must be discharged At which intervals should the activated carbon filter of the unit be replaced To use the purpose of the filter fully it should be replaced every 6 months How can I increase the efficiency of the unit External circumstances exist which may impact the efficiency of the unit Room insu...

Page 11: ...igh ambient temperatures and in the heating function to too low ambient temperatures Please observe the instructions relating to ideal operation of the unit This may also be a temporary error measurement between the start and output temperature Please switch the unit off and start it again after approx 30 minutes If the error occurs continuously the unit requires specialist inspection E4 Water tan...

Page 12: ...12 WIRING DIAGRAM ENERGY LABEL ...

Page 13: ... potential GWP 2088 kg ekv CO2 Energy class cooling heating A A Refrigerant type weight R410A 0 49 kg Optimal room size area 15 25 m 2 Voltage 220 240 V Frequency 50 Hz Rated current 5 8 A Rated air flow 400 m 3 h Hose for hot air length diameter 125 15 cm Dehumidifying 50 0 litres day Dimensions of product w x h x d 300 x 778 x 505 mm Dimensions of package w x h x d 550 x 815 x 330 mm Weight of p...

Page 14: ...potential GWP 2088 kg ekv CO2 Energy class cooling heating A A Refrigerant type weight R410A 0 605 kg Optimal room size area 25 35 m 2 Voltage 220 240 V Frequency 50 Hz Rated current 7 7 A Rated air flow 450 m 3 h Hose for hot air length diameter 125 15 cm Dehumidifying 70 0 litres day Dimensions of product w x h x d 300 x 778 x 505 mm Dimensions of package w x h x d 550 x 815 x 330 mm Weight of p...

Page 15: ...tion is located INFORMATION CONCERNING USED REFRIGERANT MEDIUM This unit is containing fluorinated gases included in the Kyoto protocol The maintanance and the liquidation must be carried out by qualified personel Type of refrigerant R410A The composition of the cooling medium R410A 50 HFC 32 50 HFC 125 The quantity of the refrigerant please see the unit label Hermetically sealed system The value ...

Reviews: