![Sinapsi esolar3be RS485 Quick Start Manual Download Page 2](http://html1.mh-extra.com/html/sinapsi/esolar3be-rs485/esolar3be-rs485_quick-start-manual_1279683002.webp)
1) The device does not turn on:
2) WEB interface is not reached from local
3) Connected devices do not communicate with esolar 3 b.e.
Temperature range:
Degree of protection:
Dimensions:
Power supply:
12.TECHNICAL DATA
+70°C
-25°C
SIN.ES3BE_QSG_1.0_en
- Verify the presence of a voltage between 9 and 48 Vdc connector ends (7)
- Verify that the power supply is capable of delivering a current of at least 4A
- In case of RS485 connection make sure that the polarities of the line are not inverted, that the cable
length is less than 300mt and that the terminating resistors are inserted.
- Check the slave addresses of the devices to be monitored and the communication parameters
(e.g. baud rate, partià bit, stop bit).
- Check that the IP addresses of the devices you want to monitor are compatible with the network
settings of esolar 3 b.e.
(e
- Check that the IP address you entered is actually the machine's IP address (Ethernet Port 1), in the
case of If you are in doubt, it is advisable to connect to the ethernet service port (192.168.1.100)
and check the con
fi
guration
- Make sure your PC's network card is con
fi
gured with a similar (and di
ff
erent) IP address to the
datalogger
- Make sure that the network cable and all equipment in between are working properly
- Make sure esolar 3 b.e. is turned on
DOWNLOAD DOCUMENTATION:
https://www.esolar.it/download-generale/
Manufactured by Cincoze Co.Ltd
10.FIRST ACCESS
13. ACTIVATION OF THE REACHABILITY SERVICE
Make sure you have your PC's network card with IP address 192.168.1.xxx where xxx should be a di
ff
erent
number from 100 and 110.
Connect the PC to one of the two network ports of esolar 3 b.e. and type the IP address 192.168.1.110 on your
browser if esolar 3 b.e. is connected through port 1 otherwise 192.168.1.100 if connected through port 2.
The login page will be shown:
esolar 3 b.e. has the SGHNET reachability service that allows you to access the interface
WEB of the device remotely, without the need to make portforwarding rules on the router
or
fi
rewall of the internet connection to which it is connected and also allows you to obtain
a DNS address like this even in case of dynamic IPs.
To activate the service, scan the QRCode present on the machine and log in or register on
MY SINAPSI portal that is opened. Once the procedure has been completed, you can log on
to the device with an address like: https://sn12345678.net.sghiot.com
Operating: -20°C ... +70°C
Warehouse -25°C ... +85°C
IP 40 (EN60529)
WxHxD 105x150x56mm
9..48Vdc max 4A
TROUBLESHOOTING
Enter the default login credentials: username = admin, password = admin.
At this point, we recommend that you consult the product manual to properly commission the datalogger.
11.PHYSICAL DIMENSIONS
Sinapsi reserves the right to make chang
es to this product without any notice