SIN.ES3BE - QuickStart Guide

SIN.ES3BE_QSG_1.0_en

Photovoltaic system e

ciency and production 

monitoring system. SGH-net compliant

- Datalogger with integrated web server

- Acquires up to 120 devices 

- Keeps up to 2 years of 15-minute data in memory

- Powerful, compact and very low power consumption

- Acquires data from 

               (a) inverter

               (b) string controllers

               (c) energy meters

               (d) interface protections

               (e) general protections

               (f) sensors of any kind

               (g) digital inputs

- 2 isolated RS485 ports

- 1 non-isolated RS485 port

- 1 RS232 port

2

1 - Ethernet port for internet and devices

2 - Service Ethernet port and devices

3 - USB ports for backup memory devices

4 - On/O

 button

5 - Activity LEDs

6 - Power LED

3

4

7 - 24vdc power supply connector

8 - RS232 serial port

9 - KNX Port (only active on KNX model)

10 - RS485 COM3 INSULATED port

11 - RS485 COM1 INSULATED port

12 - RS485 port NOT INSULATED

5 6

1

(Install at the rear 

the DIN RAIL Kit - optional)

6.FIELDBUS CONNECTION

2x M4x6mm screws

DOWNLOAD DOCUMENTAZIONE: 

https://www.esolar.it/en/useful-documentation/

esolar 3 b.e. has 3 RS485 ports, 1 RS232 port and one KNX port (active in KNX models).

Two RS485 ports are optoisolated to o

er excellent communication performance with the devices in the 

eld 

and robustness, while the COM5 is not optoisolated, so it is recommended to connect the latter to devices that 

do not present particular problems of electrical disturbances or low probability of the presence of surges. 

It is also recommended to always use appropriate cables for RS485 connections and connect always ground 

the shield conductor on one side only (preferably on the 

eld side).

RS485 - COM1 & COM3

Manufactured by Cincoze Co.Ltd

 

Before making any connection, remove the power supply and complete the wiring,

then feed the datalogger

1 x SIN.ES3BE

3.CONTENTS OF THE PACKAGE

5.POWER SUPPLY CONNECTION

To power the device use the appropriate power supply supplied with esolar 3 b.e. or one of the following 

equivalent.

 

Connect the cables in accordance with the RS485 standard, paying attention to the impedance of the

section and in the presence of the line termination resistor. It is recommended not to exceed 300mt in

length of the RS485 network in a photovoltaic 

eld, alternatively it is recommended to use RS485

repeaters. Respect polarities

 

Front

Back

NOTE: For details on the con

guration of esolar 3 b.e., please refer to the manual.

vertic

al m

ount

ing

DIN ra

il m

ount

ing

esolar 3 b.e. has 2 ethernet ports:

port 1 = normal use port, which can be used to connect the device to the internet, connect to the 

device, connect esolar 3 b.e. to the devices in the 

eld, the default address of this port is static and 

is 192.168.1.110, it is user-modi

able.

port 2 = service port, which can be used to connect to esolar 3 b.e. and to connect the datalogger to the 

devices in the 

eld, the IP address of this port is 

xed and cannot be changed: 192.168.1.100

8.ON/OFF BUTTON

- To switch on brie

y press button (4), esolar 3 b.e. will be ready for operation after about 2 minutes.

- To switch o

 esolar 3 b.e. brie

y press the button (4), after about 10...20 seconds the LED 5 and 6 will go 

   o

, you can then disconnect the power supply. the device will automatically switch on again when the 

   power is restored.

9.USB PORTS

esolar 3 b.e. has 4 USB ports to which it is possible to connect an external memory to make a local backup 

of the scheduled data. Choosing the USB port to insert the 

ash memory into outside is indi

erent. 

It is necessary to insert a 

ash memory formatted with FAT32 

lesystem and of capacity of at least 8 GB.

2 x wall mounting brackets

1 x Power con
3 x 3-pin connector for isolated RS485 ports

7

8

9

10

11

RS232 - COM 4

Do not exceed 2-3 mt of length for the RS232 section and use shielded cables.

KNX port

Observe the installation rules of KNX networks, do not exceed 350mt of length and

use only KNX certi

ed cable. Respect the polarities.