Sinapsi equobox SIN.EQRPT868XT Quick Start Manual Download Page 2

SIN.EQRPT868XT - QuickStart Guide

SIN.EQRPT868XT_QSG_2.5_en

Wireless M-Bus GATEWAY

DOCUMENTATION DOWNLOAD: 

http://www.sinapsitech.it/en/area-download/

those exceeding 500 are ignored, and may in fact belong to the plant to be checked.

In this case it is necessary to charge, in the same Gateway, a 

le with a list of devices that are part of 

its plant (Maximum 500); after uploading the 

le, the signal of the devices that are not included in the list 

is ignored by the Gateway.

The 

le, whose name must be 

list.rpt

, must be a CSV 

le with a format such as the one shown in the 

following 

gure.

SPECIAL CASES OF USE

The following image shows an installation in which, or for di

erent properties reasons , or for number of 

devices to be controlled exceeds 500 (Max 500 for each RTU1T), it is necessary to create four 

di

erent networks of SIN.EQRPT868XT Gateways.

Obviously the following is valid also in cases where there are 2, 3, 5 or a higher number of Gateways 

networks.

In order to avoid interferences between the various systems, assign to each RTU1T a di

erent 

Mesh 

network ID

. The setting is done on RTU1T through its web interface;

 Settings / Wireless Devices / 

Wireless Setup / Setup Mesh Network

.

The same 

Mesh network ID

 setting must be carried out also on all Gateways that are part of the 

network of the RTU1T which they have to communicate with.

For this procedure it is necessary to connect a PC to the Gateway to be con

gured (via USB cable).

Use the 

SIN.EQSW1

 software (downloadable from the dedicated section of sinapsi.store) and follow 

the instructions in the manual.

Note

: It is recommended not to change the Mesh Network  Channel (default = 13 both on RTU1Ts

and on Gateways), because the change may involve the transmission power of the devices.

LOADING ON GATEWAYS OF A W. M-Bus DEVICES LIST IN THE PLANT

(ONLY ON GATEWAYS WITH FIRMWARE VERSION FWRPT1_V1R20.hex ONWARDS)

Referring to the same image of the previous installation, the various Gateways receive W. M-Bus signal 

from their plant devices but they can also receive the signal from devices of adjacent plants.

If one or more Gateways receive the signal from more than 500 devices (Max 500 for each gateway),

For this procedure it is necessary to connect a PC to the Gateway to be con

gured (via USB cable).

Use the 

SIN.EQSW1

 software and follow the instructions in the manual.

GATEWAY CONFIGURATION THROUGH FUNCTIONALITY OF KEYS

GATEWAYS FIRMWARE UPGRADE

You should always check the possible release of the latest 

rmware available version of the Gateways,  

compared to the one installed on the devices in the production phase.

For this procedure it is necessary to connect a PC to the gateway to be con

gured (via cable

USB). Use the 

SIN.EQSW1 

software (downloadable from the dedicated section of sinapsi.store) and 

follow the instructions in the manual.

SETTING OF MESH NETWORK ID

Sinapsi Srl

 reserves the right to make changes to this product without any notice 

Manufactured by SINAPSI SRL - Via delle Querce 11/13 - 06083 Bastia Umbra (PG) - Italy

Change ID MESH - SIN.EQRPT868XT

1. Press keys 2 and 3 (2s. < T <6s) simultaneously.

2. On release all the LEDs (8) will 

ash at the same time to indicate 

that you have entered edit mode ID MESH

3. Now press button 3 (at least 1s.) to switch the ID MESH.

    - ID MESH 1 => Green LED (8.1) on - the others o

    - ID MESH 2 => Green LED (8.2) on - the others o

    - ID MESH 3 => Green LED (8.3) on - the others o

    - ID MESH 4 => Green LED (8.4) on - the others o

4. To SAVE press keys 2 and 3 simultaneously for more than 1s. 

    Press the 2 button to exit without saving.

5. Verify that the blue LED does not remain on steady. 

    Otherwise, restart from point 1. by selecting another MESH ID.

6. If, after switching on all four MESH IDs, the blue LED continues to 

    remain on steady, it will be necessary to con

gure the 

    SIN.EQRPT868XT via SIN.EQSW1 software.

7. Repeat for each SIN.EQRPT868XT.

Activate SND_IR mode (Installation Mode) - SIN.EQRPT868XT

a) It typically involves the installation of the AMR system and 

    subsequently the installation of the heat cost allocators

b) Both the AMR system and the distributors must be con

gured to work 

     in this mode

c) SND_IR mode activation procedure on a newly installed 

    SIN.EQRPT868XT

1. Press button 2 (t> 6s.). When pressing button 2, the green LED (8.1) 

    

ashes every second, until you are under the 6s. Once the 6s have 

    passed, the LED (8.1) 

ashes every 500ms => this indicates that the 

    "SND_IR" scan mode has been changed.

2. RPT enters the "SND_IR" scan mode. RPT receives and takes over all 

    the devices that transmit the installation W. M-Bus telegram. 

    (This frame contains no data)

3. Scan duration without user intervention 12 hours -> Manual stop of 

    the scan => press key 2 (no coded pressure time)

   Note: SIN.EQRPT868XT automatically exits the SCAN mode after 

             12 hours.

Accept mode activation ALL - SIN.EQRPT868XT

a) It is used when the commissioning is carried out after with respect to 

    the installation of the heat cost allocators

b) To activate the accept ALL mode on a newly installed SIN.EQRPT868XT

1. Press button 2 (2s. < T < 6s)

2. When pressing button 2, the LED (8.1) 

ashes every second. When the 

    key 2 is released, the LED (8.1.) remains lit to indicate the activation of 

    the accept ALL mode.

3. RPT receives and takes charge of all devices transmitting in W.M-Bus 

    including frames in Installation Mode (SND_IR) - The 

rst green LED 

    lights up permanently - Scan duration without user intervention 12 hours

4. press the button 2 (no coded pressure time) to stop the scan manually

Note: if during the scan the RPT connects into the MESH network the mode 

of operation will automatically change with the value set on the RTU.

SIN.EQRPT868XT - S - T - C Mode of operation modi

cation

1. Press keys 2 and 3 simultaneously (t > 6s.)

 

during the simultaneous pressing of keys 2 and 3, the green LEDs 

   (8.1) and (8.2) will 

ash every second, until you are under the 6s. 

   Exceeded the 6s. they 

ash every 500ms

 

When keys 2 and 3 are released, one of the green LEDs (8) starts to 

    

ash (500ms) to indicate the currently active mode of operation on 

    that SIN.EQRPT868XT

2. The mode of operation is changed by pressing the 3 key brie

y

• Mode C+T => Green LED (8.1) on - the other o

 

 

Factory setting

• Mode S => Green LED (8.2) on - the other o

• Mode T => Green LED (8.3) on - the other o

3. save settings by pressing the 2 and 3 button (t> 2s.)

4. exit => key 2 for ESC function without saving (during programming 

    status). Automatic ESC from programming status after 10 minutes 

    later.

Note: SIN.EQRPT868XT automatically exits the SCAN mode after 

          12 hours.

Restore factory settings

1. Press and hold keys 2 and 3 simultaneously.

2. Then press the reset button 4, without releasing the keys 2 and 3

3. As soon as all the LEDs (8) and (9) 

ash quickly, release all three keys.

9

1

2

1 - 100..240Vac power supply input (screw clamps)

2 - “Multi-function” button

3 - “Multi-function” button

4 -  Reset button

5 -  USB Port

3 4

6 - MESH network TX-RX LED

7 - W. M-Bus network TX-RX LED

8 - Signal level LED 

9 - Status LED 

5

6 7

8