background image

Cautions

2. Ducting

Put one end of the 150mm diameter duct into the vent hole and connect to 
grill or cowl with one duct clip included . A 150mm diameter egg-crate grille 
is included in the package to be used when installing in soffit.  If installed 
in wall a weatherproof cowl should be used. Seal grille/cowl with suitable 
sealant.

Terminal
 Blocks

Dear customers,
Please read all instructions before commencing installation.

MANROSE FAN6577 
Halogen Heater Fan & Light

INSTALLATION

A  few  minutes  of  planning  can  make  a  big  difference  to  the  installation 
time and also to your satisfaction with the function of the unit.

1. Cutting a vent

Locate  the  exterior  grill  location  on  a  wall  or  soffit,  then  cut  a  155mm 
diameter hole at this very position.

3. Suitable location

The heater must be installed at least 2.1m above the floor and no more 
than 2.4m from the ground.  The heater is most effective when you are 
standing directly beneath it, so generally the unit would be mounted in a 
place where you would stand to dry yourself.

 

For the exhaust fan to work 

efficiently,  replacement  air  of  a  volume  equivalent  to  what  is  being 

Note: 

The length of each duct is 3.0m. Make sure that from the centre of 

installation position there should be a distance within 3.0m to the outside 
vent. 

7. Wiring

Connect one end of the interconnecting 
wire  with  the  switch  panel,  and  then 
drag  the  other  end  power  cable  out  of 
the  hole  on  the  ceiling.  Open  the 
terminal block cover on the housing and 
make connection as the wiring diagram 
instructs,  then  reposition  the  terminal 
block  cover.  Tuck  the  excess  wire  into 
the  ceiling  so  as  to  leave  the  housing 
enough room to fix in.

INSTALLATION INSTRUCTIONS AND HOLE-CUTTING TEMPLATE

Read and save these instructions!

Please use this card as hole cutting template 470mm x 320mm.

Wall venting shown

wall

sealant ventiduct

bathroom
heater

ceiling joist

ceiling

fascia

duct clip

4. Prepare the ceiling

5. Remove the fascia

6. Disconnect 

Power cables to LED Panel.

Remove  4  rubber clips  at  2  ends  of  the  rectangle  air  inlet  grilles. 

Heater Unit

Rubber clip

Air inlet grille

Glass shield

Screw behind rubber

Use this template to mark the hole outline on the ceiling. Make sure 
a distance between the edges and wall is no less than 250mm. Also 
from the rooftop should be a minimum 220mm height to the ceiling.

Remove the halogen heat lamp 
from the heater unit and keep it in 
a  safe  place. 

Do  not  touch 

 this

 

lamp with your bare skin.

Natural  skin  oils  and  salts  damage  new  halogen  lamps  and 
shorten their life. 

Only handle a new heat lamp with soft, dry, clean, 

lint-free  cloth  or  paper. You  can  wear  gloves,  cover  your  fingers  or 
wrap the heat lamp until it is installed (so long as you remove all cloth 
or paper when finished).

•  The power cable of this product must withstand

 

a minimum 10A    

  load.
•  The main supply and interconnecting cables required for installation  
  of this unit are not included.
•  This unit must be properly grounded.
•  The disconnection of the product is achieved by incorporating a    
  switch in the fixed wiring in accordance with the wiring rules. The   
  heater must be isolated from the power by means of a disconnection  
  switch with a contact separation of at least 3mm. 

WARNING

:  Indicates  that  injury  or  death  could  occur  if  below 

Warnings 

are not followed.

This  unit  must  be  installed  to  comply  with  the  appropriate  council 
regulations  and  the  Australia  and  New  Zealand  wiring  rules 
AS/NZS3000:2007 or lastest edition thereof.

All wiring must be carried out by a Licensed Electrician in accordance 
with all applicable codes and standards.  

Use  this  heater  only  as  described  in  this  manual.  The  manufacturer 
does  not  recommend  any  other  use  as  this  may  cause  fire,  electric 
shock,  or  injury  to  persons.  If  you  have  questions,  contact  the 
manufacturer or local agent.

Make sure the power is off before the installation. 

The heaters glass shield is hot when in use. Do not touch the heat lamp 
and glass shield with any part of your body when in use.

For  the  purpose  of  avoiding  any  dangerous  gas  leaking  into  your 
bathroom, the duct vent of the heater must not be laid together with the 
duct vent  of air-fueled water heater or other open-fire appliances into 
the same flue.

The heater is to be installed so that switches and other controls cannot 
be touched by a person in the bath or shower.

This  unit  should  not  be  installed  directly  above  a  shower  or  bathtub. 
The  unit  must  not  be  installed  in  a  position  where  water  may  splash 
onto the unit.

CAUTION

: Possibility of damage to equipment, installation or premises 

if below 

 

are not followed.

•  The appliance is not intended for use by persons (including children)  

 

  with reduced physical, sensory or mental capabilities, or lack of    

 

  experience and knowledge, unless they have been given supervision or   
  instruction concerning use of the appliance by a person responsible for    
  their safety.
•  Children should be supervised to ensure that they do not play with the    
  appliance.
•  The appliance shall, under no circumstances, be covered with insulating  
  material or similar material.
•  Regulations concerning the discharge of air have to be fulfilled.
•  The unit must not be installed beneath a fixed socket.
•  The unit is designed for installation in flat ceilings only. Do not mount it 
  on a sloping ceiling or a vertical wall.
•  Before commencing any cutting, check in the ceiling space that there are  
  no obstructions such as electrical wiring, hidden utilities or ceiling joists    
  and that there is sufficient height clearance for the housing. Check that    
  the electrical wiring can be routed from the wall switches to the mounting  
  location.
•  Joists, beams and rafters shall not be cut or notched to install the   

 

  appliance.

!

!

!

!

!

!

!

!

!

extracted must be able to enter the room. Generally, this air would be 
drawn under the door with a minimum space of 20mm. If the room is 
airtight, the fan will function poorly.

1

2

IR

LED

LED

 :Thermal Protector

M:Motor
C:Capacitor
LED: Lamp
IR: Halogen

Remove  the  screws  hidden 
behind. Remove the fascia. 

Note:

 

 Be careful while removing 

the  screws  so  that  the  fascia 
does not drop to the ground.