Yellow - Switched Live

Orange - Permanent Live

Black - Neutral

INTERNAL WIRING

DETAILED VIEW

Only Adjust with power switched off.

Timer Adjustment for XF/XP150T, XF/XP150AT

Any fan with a time delay fitted will run approximately one minute after it has been switched off. The time delay can 
be increased by firstly switching off the power to the fan, remove front cover, and insert a small allen key in to the slot, 
marked    in Diagram 3A, and turning clockwise to reduce the time and anti-clockwise to increase the time. Only 
adjust with power switched off.

The minimum time the timer will run for is 20 seconds and the maximum is about 30 minutes.

NOTE:  (i)   The fan is to be installed so that the blades are 2.1m above the floor. For best results    

 

this Extractor Fan should be fitted as high on the wall as possible, or if preferred, on the  

 ceiling.

 

(ii)  Do not install the unit within a shower cubicle. Use our shower fan SF150 models  
(iii)  Switch off mains supply before making electrical connections. This system should  

 

 

be installed by a qualified electrician.

 

(iv)  This fan is double insulated and does not require an earth.

 

(v)  When installing fan through an external wall, an external wall grille must be fitted  

 

 

at all times.

DIAGRAM 3: Auto Shutter Models

DIAGRAM 3A: Timer Adjustment for Auto Shutter Fans XF/XP150AT

Thank you for selecting our Manrose 150mm Wall/Ceiling Fan.

Please read all instructions before commencing installation. 

1.  Cut a 160mm diameter hole in the wall. If the fan is to be fixed onto the ceiling ensure that  
 

the hole is between the joists.

2.  Fit 150mm ducting flush to the plaster.

3.  Remove the cover from the fan by simply unclipping the fascia. The front cover screw and  
 

plug are conveniently located within the fan housing as shown in diagram 1 & 2.

4.  Hold the body of the fan against the wall or ceiling and mark the four screw holes and the  
 

cable entry. 

IMPORTANT:

 Ensure that the fan is square on wall or ceiling.

5.  Bring power cable into position, as marked. Allow an extra 230mm (9”) protruding to  

 

 

facilitate connection. Fan should only be installed by fixed wiring, a flexible cord should not  

 

be used.

6.  If an XP150 kit - Select a suitable position on the outside wall for the weatherproof cowl.  

Carefully remove the cowl from its housing by levering gently at the sides with a small 
screwdriver.  Cut a 160mm hole ensuring first that the area is free from obstruction.

7. 

Wiring of Standard/Pullcord Model XF/XP150 (see diagram 1) 

 

(Pullcord model unsuitable for ceiling mounting)

 

 

The fan can be connected to the light switch so that the fan will start when the light is    

 

switched on. The fan should not be accessible to a person using either the shower or the bath.  

 

 

NOTE:

 All wiring must be fixed securely and the cable to the fan should be a minimum of 1mm2 

in section. All wiring must comply with current Regulations. This system should be installed by a 
qualified electrician.

Wiring of Timer Model XF/XP150T (see diagram 2).

 

 

The  fan can be connected to the light switch so that the fan will start when the light is    

 

switched on.  When the light switch or pullcord is switched off the fan will run for between 20  

 

sec & 30 minutes (pre-set to 1 minute). The fan should not be accessible to a person using  

 

either the shower or the bath. 

MANROSE CLASSIC XF/XP150 CEILING/WALL 
EXTRACTOR FANS

INSTALLATION INSTRUCTIONS

C L A S S I C   S E R I E S

We reserve the right to change specification without prior warning

Manrose is proudly distributed by Simx Limited
PO Box 14 347, Panmure, Auckland, NZ.  Technical Support (09) 259 1662  
e: [email protected]  |  www.simx.co.nz  |  www.manrose.com.au

IMPORTANT NOTE: 

 

If your fan is equipped 
with auto shutters it will 
be fitted with a thermally 
activated mechanism 
that opens and closes 
the shutters. When the 
unit is turned on/off the 
automatic shutters will 
take approximately 45 
seconds to respond.