This light fitting only operates when the PIR sensor is activated by heat movement within its detection zone. Once power is
connected, the unit requires approx. 60 seconds to warm up.
Do not commence any walk tests until this has occurred.
CALIBRATION
The TIME adjustment has a minimum of approx. 30 seconds (counter clockwise rotation to the end) which it should be set to
for walk testing the unit (Fig D). Adjust this setting clockwise to the preferred duration the light is activated for when it detects
movement. The maximum clockwise setting will be approx. 6 minutes. The timer will restart each time the sensor detects any
new movement.
The LUX adjustment sets the acceptable amount of light present before the unit will start detecting. Rotating the dial clockwise
to the end will set it to full daylight operation. Use this setting for walk testing the unit (Fig D). Fully rotating counter clockwise
will set the unit to activate after dark only.
The PIR sensor has a 140° detection angle. This detection angle can also be aimed 90° left or right by pivoting the PIR cover
where it joins the main housing.
The lens mask supplied can be used when needed for restricting detection angles of the PIR (Fig E). Removing the largest
centre segment provides a 40° detection area, while removing all segments provides maximum 140° angle. The mask clips
into place. Remove one segment at a time, aim, and check in walk test mode. Continue removing segments until correct
coverage is achieved.
Time/Sensitivity Adjustment
INSTALLING YOUR SENSOR LED II LIGHT
This light fitting is rated to IP44. This means that it is suitable in areas which may receive light rainfall. Please ensure the
desired location does not exceed this rating.
Switch off the power supply before commencing electrical work.
Using a flat head screwdriver, carefully lever the side tabs to separate the mounting base from the
main housing (Fig A).
Pierce the power entry grommet on the mounting base and slowly draw a round mains power
cable through the power entry hole. Recommended use of 1.5mm
2
- 2.5mm
2
wire
for installation.
Firmly secure the base to the wall or ceiling using the mounting screws provided. Mounting holes
located in the base are at 60mm centres.
Wire the cable to the terminal block, ensuring accurate polarity. Failure to do this correctly will result
in irreparable lamp and sensor failure. A terminal for Earth parking is provided if required. Locate the
main housing over the base and push together until it ‘clicks’ into finished position (Fig B).
Adjust the base pivot to orientate the fitting with the sensor adjustors pointing downwards.
Tighten thumb screw to secure. Aim spotlight head to suit the locations.
Fig D
Fig E
Minimum On Time
setting
Maximum LUX
setting
Fig A
Fig B
Fig C
“click”
“click”
(60˚ left & right-
2 spot pan together)
124mm
135mm
88mm
30˚
30˚
50˚
PIR LENS MASKING
The purpose of the lens mask is to block out
areas not desired for detection. Apply to PIR
lens as required for your location.
Care and consideration should be taken when the unit is located close to property boundaries, to avoid unnecessary spill
light or glare to neighbours, and to avoid unwanted activation by passing pedestrians or vehicles.
Special Note
SUPERIOR ADJUSTMENT VERSATILITY
Dual Mounting Options