PROBLEM

PIR sensor will not operate at

all.

The PIR sensor will not 

operate at night.

Unit activates during the 

daytime

PIR coverage is

poor/sporadic

❏ 

Detection range varies from

day to day

SOLUTION

Check that the power is switched ON at the circuit
breaker/internal wall switch.

Turn OFF the power to the unit and check the wiring
connections as per the diagram (see previous section 3).
Ensure no connections are loose.

Check the lamp. If the lamp has failed, replace. Ensure that
the lamp is seated correctly in the lampholder.

The level of ambient light in the area may be too bright to
allow operation at the current DUSK setting. During the hours
of darkness, adjust the DUSK control slowly clockwise until
the lamp illuminates. Refer to previous section for more
details.

The level of ambient light in the area may be too dark for the
current DUSK setting. During daylight, adjust the DUSK
control slightly anti-clockwise. When the lamp load
extinguishes, enter the detection area. If the PIR still
activates, the setting is still too high. Repeat the above
procedure until the PIR does not activate when you enter the
detection area. Refer to previous section for more details.

Unit may be poorly located. See previous section - ‘Selecting
The Location’ and re-locate the unit.

PIR sensors are influenced by climatic conditions. The colder
the ambient temperature, the more effective the sensor will
be. You may need to make seasonal adjustments to the
sensor head position to ensure trouble-free operation all year
round.

LHT0088&89 251012:lht008889.qxd  10/26/12  5:14 PM  Page 10

Summary of Contents for LHT0088

Page 1: ...LHT0088 LHT0089 LHT0151 SECURITY FLOODLIGHT INSTALLATION MANUAL...

Page 2: ...Less sensitive More sensitive TOP VIEW 200 SIDE VIEW 12m 2 5m A C B D...

Page 3: ...clause 1 is limited to replacement or repair of the Goods only at our option To the extent permitted by law we exclude liability for a consequential loss or any other loss or damage caused to propert...

Page 4: ...tradesperson or electrician SECTION TWO SELECTING THE LOCATION The motion detector has a number of detection zones at various vertical and horizontal angles as shown see diagram A A moving human body...

Page 5: ...andled using a dry cloth Ensure the bulb is correctly fitted in the lampholder before use Re attach the front cover do not overtighten the fixing screw IMPORTANT Switch off the electricity at the fuse...

Page 6: ...t to the Moon setting and Time is set to a minimum If not set as shown in diagram G Max turn knob clockwise min turn knob anticlockwise Turn the power to the unit on The lamp will illuminate for appro...

Page 7: ...See diagram G the Dusk adjustment knob is indicated by the Moon and Sun symbols Set the DUSK control knob fully anti clockwise Wait until darkness falls When the ambient light level reaches the level...

Page 8: ...illuminate for a user defined time between 1 and 8 hours The time can be set by rotating the centre adjustment knob as required See diagram G the adjustment knob is identified by the letter T inside...

Page 9: ...switch circuit breaker off on with one second and the unit will return to Sensor Control Mode The light will illuminate only when motion is detected Sensor Control Mode is indicated by scrolling LEDs...

Page 10: ...ess adjust the DUSK control slowly clockwise until the lamp illuminates Refer to previous section for more details The level of ambient light in the area may be too dark for the current DUSK setting D...

Page 11: ...E G F H Lens Mask Restrict long detection Restrict short detection Restrict RHS detection Restrict LHS detection Dusk Dawn Sensor on time control Time Control Adjuster factory set to 1 hr min...

Page 12: ...Place this edge against wall and use diagram to estimate incoming cable length 75mm 3 25mm 1 INCOMING WIRE TEMPLATE Use this diagram to estimate incoming cable length...

Reviews: