SImx LHT0088 Installation Manual Download Page 1

LHT0088
LHT0089
LHT0151

SECURITY FLOODLIGHT

INSTALLATION MANUAL

LHT0088&89 251012:lht008889.qxd  10/26/12  5:14 PM  Page 1

Summary of Contents for LHT0088

Page 1: ...LHT0088 LHT0089 LHT0151 SECURITY FLOODLIGHT INSTALLATION MANUAL...

Page 2: ...Less sensitive More sensitive TOP VIEW 200 SIDE VIEW 12m 2 5m A C B D...

Page 3: ...clause 1 is limited to replacement or repair of the Goods only at our option To the extent permitted by law we exclude liability for a consequential loss or any other loss or damage caused to propert...

Page 4: ...tradesperson or electrician SECTION TWO SELECTING THE LOCATION The motion detector has a number of detection zones at various vertical and horizontal angles as shown see diagram A A moving human body...

Page 5: ...andled using a dry cloth Ensure the bulb is correctly fitted in the lampholder before use Re attach the front cover do not overtighten the fixing screw IMPORTANT Switch off the electricity at the fuse...

Page 6: ...t to the Moon setting and Time is set to a minimum If not set as shown in diagram G Max turn knob clockwise min turn knob anticlockwise Turn the power to the unit on The lamp will illuminate for appro...

Page 7: ...See diagram G the Dusk adjustment knob is indicated by the Moon and Sun symbols Set the DUSK control knob fully anti clockwise Wait until darkness falls When the ambient light level reaches the level...

Page 8: ...illuminate for a user defined time between 1 and 8 hours The time can be set by rotating the centre adjustment knob as required See diagram G the adjustment knob is identified by the letter T inside...

Page 9: ...switch circuit breaker off on with one second and the unit will return to Sensor Control Mode The light will illuminate only when motion is detected Sensor Control Mode is indicated by scrolling LEDs...

Page 10: ...ess adjust the DUSK control slowly clockwise until the lamp illuminates Refer to previous section for more details The level of ambient light in the area may be too dark for the current DUSK setting D...

Page 11: ...E G F H Lens Mask Restrict long detection Restrict short detection Restrict RHS detection Restrict LHS detection Dusk Dawn Sensor on time control Time Control Adjuster factory set to 1 hr min...

Page 12: ...Place this edge against wall and use diagram to estimate incoming cable length 75mm 3 25mm 1 INCOMING WIRE TEMPLATE Use this diagram to estimate incoming cable length...

Reviews: