www.simulab.com
USER GUIDE v1.0
System Set Up
Software Installation
Troubleshooting
Pacer
Man
TM
Page 1: ...www simulab com USER GUIDE v1 0 System Set Up Software Installation Troubleshooting PacerMan TM...
Page 2: ...ware Guide 18 Launching Software 18 Home Page 19 Instructor Mode Scenario Setup 20 Calibration 21 Monitor Page 22 Patient Vitals 23 New Scenario 24 Additional Functionality Bar 25 Defibrillator Interf...
Page 3: ...eal time Improve procedural performance through instructor led competencies and self directed repetition Practice decision making based on outcome options Train using blind and ECG guided techniques I...
Page 4: ...omponents BODY FORM Simulab Corporation 4 System Components Replaceable Tissue Vessel Channel Cover Tissue Cradle Serial Number Label Battery Well Torso Cover Fluid Reservoir and Cap Head Cover Arteri...
Page 5: ...Port Body Form to USB Port Power Switch Power Cord Connection In Use Valve Drain Connection POWER DRAIN INTERFACE PANEL COMMUNICATION PANEL Battery Pack Or Or OEM Extension Cable Universal Extension...
Page 6: ...nts continued Simulated Arterial Blood SimuSensor Venous Blood Concentrate Venous Fluid Mixing Bottle Fill Port with Funnel Drain Tube with Stop Clip Arterial Hand Pump Fill line 1 1 4 4 4 3 3 6 7 7 6...
Page 7: ...wer switch and then turn the valve to the IN USE position Launch PacerMan software Choose Instructor or Student Mode If using Instructor Mode set scenario parameters and then click begin You ll hear t...
Page 8: ...luetooth drivers to be installed when you use the PacerMan System for the first time Window 7 or higher 512 MB RAM Disk Space required if net 4 5 is not already installed If it is already installed th...
Page 9: ...ck Next Click Next and proceed with the software installation Software installation will begin Note if you click Cancel on this screen it will end the installation Once your software is successfully i...
Page 10: ...PacerMan has a serial number that is a unique identifier and will be displayed in the discoverable device name The Serial number can be found on a label under the PacerMan body form cover The PacerMan...
Page 11: ...ct Add a device select the PacerMan Next 4 Follow any other instructions that might appear In Windows 8 1 1 Turn on your PacerMan System 2 Select the Start button type Bluetooth select Bluetooth setti...
Page 12: ...Contact Simulab for assistance if anything is missing or damaged Remove the torso and head covers from the body form Then take off the black vessel channel cover by using the finger clips to gently li...
Page 13: ...sue in the two places shown Make sure it s snapped securely into both ends Replace the vessel channel cover ensuring it snaps into place Lay the arterial line into the channel in the head area and rep...
Page 14: ...be a small release of fluid Mix SimuSensor Venous Concentrate blue with water in the Fluid Mixing Container by following these steps MIXING RECIPE 1 Fill water up to the 30 oz line 2 Add 2 oz of the B...
Page 15: ...cover back on and the cord will fit through the mouse hole as shown Plug the battery cord into the port labeled DC IN on the panel For wall power plug the Wall Power Supply into the DC IN port and pl...
Page 16: ...PACING GENERATOR BODY FORM TO PC 7 8 OEM Extension Cable Your Pacing Generator Medtronic plug in Universal Extension Cable Simulated Extension System Communication Panel Your Pacing Generator Distal...
Page 17: ...ist Tissue Ensure tissue is connected properly See Install Tissue on page 12 Fluid Ensure tank is filled See Prepare Fluid System page 14 Extension System Ensure the Extension System is connected See...
Page 18: ...ough the Start Menu or in the directory where your software was installed The PacerMan System Home Page will open and you will be ready to begin LAUNCHING PACERMAN SOFTWARE The first time you connect...
Page 19: ...rning 1 3 2 4 1 2 3 4 2 Instructor Mode Allows you to select a scenario set up by choosing multiple outcomes for transvenous or transcutaneous pacing see page 20 User Support The User Support Section...
Page 20: ...come settings Note keeping the default settings will not have an impact on the scenario Transvenous Pacing Settings Capture Threshold Decide what a successful mA output will be to gain capture Outcome...
Page 21: ...ks your system status and primes the tissue fluid system If any status items respond with No you ll need to check to see if the item was installed correctly Calibration Calibration Troubleshooting If...
Page 22: ...e Buttons Transcutaneous Pacing Panel Patient Vitals Heart Rate Arterial Blood Pressure SpO2 NIBP Additional Functionality Bar Sound Extended Patient Monitor Intracardiac ECG Tracing Next the Monitor...
Page 23: ...the system when you start a new scenario Monitor Page continued NEW SCENARIO PATIENT VITALS New Scenario button Home Button To turn on the individual patient vitals move the toggle to the ON position...
Page 24: ...reen Resolution or Screen Appearance and set to Extend this display Intracardiac ECG Tracing Toggle The PacerMan software will display an Intracardiac ECG Tracing on the Monitor Page The ECG tracing r...
Page 25: ...brillator display Rate Adjust rate displayed in field If you choose Transcutaneous Pacing you ll see the Main Interface Page will open and display the patient monitor with a simulated defibrillator wi...
Page 26: ...Simulab Corporation 26 Software Guide Choose Your Procedural Option Transcutaneous Pacing Blind Approach ECG Guided Approach...
Page 27: ...rger Then plug the battery charger into the wall A red indicator light means it s still charging and a green light means the battery is fully charged To refill the pulse bulb connect the fill line to...
Page 28: ...The pulse bulb can then be reconnected to the vessel The body form is now ready for use Attach the drain tube to the drain port on the Power and Drain Interface Panel make sure the clamp is closed NOT...
Page 29: ...e the mixing container under the drain line and release the clamp the system will fully drain Finally remove the drain line seal the mixing container for storage Turn System Power button to the OFF po...
Page 30: ...an with rubbing alcohol especially where fluid pools near connection ports to prevent staining To store the system check to make sure all the system components are in the carrying case When repacking...
Page 31: ...aintenance and Storage 31 PacerMan System Packing and Storing continued Store replaceable tissues in a plastic zip lock bag This will contain any excess fluid released and prevent evaporation of fluid...
Page 32: ...ion or Universal Extension Cable The OEM Extension Cable works with most Medtronic models 16 How do I prepare the SimuSensor Venous concentrate Fill water to the 31oz line of the mixing container Add...
Page 33: ...h device displays a serial number that uniquely identifies each PacerMan body form to the Bluetooth signal The serial number is located under the torso cover 10 What if I have two systems in one room...
Page 34: ...tem is plugged into the accessory port 16 Inquiry Solution Page The tissue is bleeding This may indicate the tissue requires replacement soon You can try reducing the fluid reservoir to 3 4 full Or ch...
Page 35: ...tory Turn up the gain or decrease the ultrasound frequency to improve the image Image appears white Make sure the arterial line and arterial pulse bulb are filled correctly 28 Image appears compromise...
Page 36: ...There are no ECG Rhythms on the Intracardiac ECG Tracing The ECG tracing requires that the distal pin be removed from the extension system and the proximal pin properly placed in the proximal port of...
Page 37: ...ion plug the USB cord into the body form and into your PC Or connect via Bluetooth then once connected open the software If required restart the PC 10 16 Inquiry Solution Page Can I leave fluid in the...
Page 38: ...00 1260 90 DAY WARRANTY Simulab offers a 90 day warranty on all parts of the PacerMan System assuming reasonable wear and tear with the exception of any used replaceable tissues For warranty claims pl...
Page 39: ...acility in Seattle Washington USA at the customer s request ANNUAL REFURBISHMENT INITIATED BY CUSTOMER To receive system refurbishment please contact Customer Service for an RMA number Customer Servic...
Page 40: ...atalog Replacement Parts Catalog To reorder replacement parts go to www simulab com PacerMan Replaceable Tissue PMT 10 Carrying Case PMP 1001 Head Cover PMP 1003 Torso Cover PMP 1002 Fluid Reservoir C...
Page 41: ...41 PacerMan System Replacement Parts Catalog continued Simulated Extension System PMP 1006 Body form to USB Cable PMP 1007 Wall Power Supply PMP 1008 Battery Pack PMP 1009 Battery Charger PMP 1010 OEM...
Page 42: ...eplacement Parts Catalog continued Universal Extension Cable PMP 1013 Drain Tube with Stop Clip PMP 1011 Venous Fluid Mixing Bottle PMP 1014 SimuSensor Venous Blood Concentrate SSV 16 Simulated Arteri...
Page 43: ...Replacement Parts Catalog 43 PacerMan System Replacement Parts Catalog continued Fill Line CLP 1003 Arterial Hand Pump CLP 1008 PacerMan Software Kit PMP 1015 User Guide PMP 1015...
Page 44: ...T 206 297 1260 866 400 1260 F 253 681 7667 E info simulab com www simulab com PMP 1015 Copyright Simulab Corporation 2017 All rights reserved...