background image

Apply the electric installation standards, as
well as the following points: 

- switch off the mains before any interven-

tion.

- use flexible cables.

- connect the ground cables.

- after installation, no traction must be

applied to the terminal strips.

* Possibility of wiring a second photocell

betwee terminal 14 and 17.

RSA Hz

- 2005324

Radio receiver for rolling garage door

®

Read carefully these

instructions before any use.

5011017B

GB

S.A.S. au capital de 5 000 000 

- Z.I. Les Giranaux - BP71 - 70103 Arc-Les-Gray CEDEX - RCS GRAY B 425 650 090 - SIRET 425 650 090 00011 - n° T.V.A CEE FR 87 425 650 090

- Maximum current for accessories (cells, keypads, loops, sensor bar, etc…) : 0.33A i.e. 8W max. or 13W

intermittent (orange light 10W + accessories 3W.).

- Orange light : 24V, 10W max ou 230V 40W max
- Area lighting : 230Vac, 500W.
- Auxiliary output : Contact NO, 250Vac 500W.
- Operating class : 1, the ground must be connected.
- Box dimension: 150 x 150 x 40 mm

The RSA Hz receiver is used to control a rolling garage door fitted with a 230V motor with built-in endstops
using transmitters. (réf: 2005323 et 2004328). 
Different safety and signaling systems can be connected to the RSA HZ (sensor bar, photocells, flashlights, area
lighting).

This product complies with the standard “SHousehold and similar electrical appliances - Safety - Part 2-95:
Particular requirements for drives for vertically moving garage doors for residential use” IEC 60335-2-95.

This contributes to implementing installations complying with the standard “safety in using motorised doors”
NF EN 12453. Rsa hz must be installed inside the garage with a motor equipped by a manual override system.

1

Description and technical data

UNIVERSAL KEY SWITCH

(OUTDOOR)

SWITCH (INDOOR)

PHOTO-CELLS BARRIER*

SAFETY EDGE

SINGLE PHASE MOTOR

LIGHTING OR/AND SIGNALING

SAFETY BRAKE

2

Wiring

- Example of installation

(wire section : 0,75mm

2

)

- Wiring of lighting or signaling

(230V 500W max.)

- Wiring of safety edge

Hereby SIMU declare that this equipment “RSA Hz” is in compliance with the essential requirements and other relevant provisions of
directive 1999/5/EC. A declaration of conformity is available at the web adress : 

www.simu.fr

, heading 

“Normes”. 

Usable in 

UE, 

RESISTIVE SAFETY EDGE

FRABA type SAFETY EDGE

WHITE (-)

BROWN (+)

GREEN (SEC)

- Power supply voltage : 230Vac 50-60 Hz.
- Fuse : 250V 5A with timeout
- Max motor power : 230Vac 750W.
- Protection rating : IP 44.
- Ambient operating T°: -15°C à +55°C. 
- Radio frequency : 433,42MHz
- Accessory power supply : 24Vcc (direct).
- Resistance values for resistive sensor bar : From 5 to 14K

UNIVERSAL KEY SWITCH

(OUTDOOR)

SWITCH (INDOOR)

Pull the antenna wire through
the right-hand wire grommet

TRANSMITTER CELL

RECEIVER CELL

3x1,5mm

2

SAFETY
BRAKE

MOTOR

- Wiring of single phase motor

- Wiring of photo-cells 

(ref.:9012888)

- Wiring of control switches

3

Checking the motor’s rotation direction

4

Parameters

1- 

Powering on the product: the display indicates the value

2- 

Check the motor’s rotation direction using the 

and 

keys.

- Press and hold the

key to open

the door.

- Press and hold down the

key to

close the door.

- If the operation is reversed, power off the product, and revert the motor’s wiring (terminals 7 and 9).

Refer to the motor's installation manual to set the end stop system.
3- 

Measure the motor operating time using permanent running (e.g. 20sec. for rising), then set the T0 para-
meter with a value slightly above the time observed (about +3 sec.).

Motor operating time 

to 

(Increment of 1 sec.).

The default modes adjusted a SIMU correspond to the main part of installations and uses of roller garage
doors.Nevertheless, the SA Hz control box can be completely and easily programmed in order to obtain a per-
sonalized working according to the accessories connected and the specific working mode desired by the user.

Use the 

or 

keys to browse the

menu and display the parameter required.

1s.

One second after releasing the key, the screen indicates
the parameter value to change. (display blinks).

- To return to the menu, press the 

or 

keys to return to value C1 (or any other value indicating

the product’s operation: see § 5) or after a one-minute waiting time.

Use the 

or 

keys to change the value of

the parameter. The last value is recorded automati-
cally (the display is fixed when pressing the keys).

: Automatic mode

Pressing the remote control opens and closes automatically after timeout T1.
During closing, pressing the remote control again or the detection of an obstacle reopens the door.

Closing time of the door

to 

(Increment of 1 sec.).

4.1 Configuring the operating mode: parameter 

(plant value = 05)

- Certain operating modes impose connecting safety accessories (NF EN 12453). Non compliance with these

rules can lead to a facility hazardous for its users.

The RSA Hz has six operating modes:

Mandatory installation
of safety accessories.

: Forced mode with

and

keys on the keyboard (default mode) :

This mode is used to control the door using the

and 

keys on the RSA Hz box in

the endstop adjustment phase.

- Press and hold

to open. Press and hold

to close.

In this mode, the safety
devices are deactivated

: Semi-automatic mode

Pressing the control triggers opening or closing. Pressing again during opening has no effect.
Pressing during closing re-opens the door.

STOP

: Sequential mode

Cyclic operation (up / stop / down / stop...). Pressing during opening or closing stops
without reversion.

STOP

: Sequential mode + Timeout

Similar to the sequential mode, but with automatic closing aftert timeout T1

Closing time of the door

to 

(Increment of 1 sec.).

STOP

: 3-button mode

This mode is used to set a separate control for opening, closing, and stopping the door.

1 / 2

Summary of Contents for RSA Hz-2005324

Page 1: ...3 sec environ Temps de fonctionnement moteur à Incrément de 1 sec Les paramètres par défaut réglés en usine correspondent à la majeur partie des installations et utilisations de portes de garage enroulables Néanmoins le boîtier de commande SA Hz peut être entièrement et facilement configuré afin d obtenir un fonctionnement personnalisé et optimal en fonction des accessoires qui lui sont raccordés ...

Page 2: ...tre valeur usine 00 Pas d auto test de l accessoire raccordé mode par défaut Auto test pour cellules photo éléctriques par coupure d alimentation Attention la cellule émetrice doit être alimentée sur les bornes 10 12 et la cellule réceptrice sur les bornes 10 11 Auto test pour accessoire muni d une entrée TEST cellules ou barre palpeuse Auto tester l entrée sécurité 3 paramètre valeur usine 00 Con...

Page 3: ...g of single phase motor Wiring of photo cells ref 9012888 Wiring of control switches 3 Checking the motor s rotation direction 4 Parameters 1 Powering on the product the display indicates the value 2 Check the motor s rotation direction using the and keys Press and hold the key to open the door Press and hold down the key to close the door If the operation is reversed power off the product and rev...

Page 4: ...tton mode using a reverter with three keys wired onto the START SEC2 and SEC3 inputs if the latter are configured non wired chapter 4 2 Clearing all remote controls is performed by pressing and holding for 3 seconds the key until dashes appear No self test of the accessory connected default mode Self test for photocells by power supply cutting Caution the transmitting cell must be supplied on term...

Reviews: