GB
DECLUTCHING SECURITY BOX
TRANSLATED
INSTRUCTION
Read carefully these
instructions before any use.
S.A.S. au capital de 5 000 000
�
- Z.I. Les Giranaux - BP71 - 70103 Arc-Les-Gray CEDEX - FRANCE - RCS VESOUL B 425 650 090 - SIRET 425 650 090 00011 - n° T.V.A CEE FR 87 425 650 090
5124491A
Hereby, SIMU, declares that the device is in compliance with the essential requirements and other relevant provisions of the Machinery
Directive 2006/42/CE.
A declaration of conformity is available at www.simu.com
WARNING! Important safety instructions. Carefully read and comply with all the warnings and instructions that come with the product as incorrect
installation can cause injury to people and animals and damage to property. The warnings and instructions give important information regarding
safety, installation, use and maintenance. Keep hold of instructions so that you can attach them to the technical file and keep them handy for future
reference.
GENERAL SAFETY
This product has been designed and built solely for the purpose indicated herein. Uses other than those indicated herein might cause damage to
the product and create a hazard.
- The units making up the machine and its installation must meet the requirements of the following European Directives, where applicable: 2004/108/EC, 2006/95/
EC, 2006/42/EC, 89/106/EC, 99/05/EC and later amendments. For all countries outside the EEC, it is advisable to comply with the standards mentioned, in
addition to any national standards in force, to achieve a good level of safety.
- The Manufacturer of this product (hereinafter referred to as the “Firm”) disclaims all responsibility resulting from improper use or any use other than that for
which the product has been designed, as indicated herein, as well as for failure to apply Good Practice in the construction of entry systems (doors, gates, etc.)
and for deformation that could occur during use.
- Installation must be carried out by qualified personnel (professional installer, according to EN 12635), in compliance with Good Practice and current code.
- Before commencing installation, check the product for damage.
- Make sure the stated temperature range is compatible with the site in which the automated system is due to be installed.
- Do not install this product in an explosive atmosphere: the presence of flammable fumes or gas constitutes a serious safety hazard.
- Disconnect the electricity supply before performing any work on the system. Also disconnect buffer batteries, if any are con-nected.
- Make sure the earth system has been installed correctly: earth all the metal parts belonging to the entry system (doors, gates, etc.) and all parts of the system
featuring an earth terminal.
- Installation must be carried out using safety devices and controls that meet standards EN 12978 and EN 12453.
- Install any fixed controls in a position where they will not cause a hazard, away from moving parts. More specifically, hold-to-run controls must be positioned
within direct sight of the part being controlled and, unless they are key operated, must be installed at a height of at least 1.5 m and in a place where they cannot
be reached by the public.
- Attach a label near the operating device, in a permanent fashion, with information on how to operate the automated system’s manual release.
- Only use original spare parts for any maintenance or repair work. The Firm disclaims all responsibility for the correct operation and safety of the automated
system if parts from other manufacturers are used.
- Do not make any modifications to the automated system’s components unless explicitly authorized by the Firm.
- Instruct the system’s user on what residual risks may be encountered, on the control systems that have been applied and on how to open the system manually
in an emergency. give the user guide to the end user.
- Dispose of packaging materials (plastic, cardboard, polystyrene, etc.) in accordance with the provisions of the laws in force. Keep nylon bags and polystyrene
out of reach of children.
The declutching security box is designed to control the following products SIMU:
- Centris range of motors with declutching cable
- Control boxes SIMU: SD410, SD510, RSA, RSA Pro.
Any use of the declutching security box outside the scope described above is prohibited. It excludes, as any disrespect safety instructions and
instructions in this instruction sheet, any liability and warranty SIMU.
SCRAPPING
Materials must be disposed of in accordance with the regulations in force. There are no particular hazards or risks involved in scrapping the automated system.
For the purpose of recycling, it is best to separate dismantled parts into like materials (electrical parts - copper - aluminium - plastic - etc.).
DISMANTLING
If the automated system is being dismantled in order to be reassembled at another site, you are required to:- Cut off the power and disconnect the whole electrical
system.- Remove the actuator from the base it is mounted on.- Remove all the installation’s components.- See to the replacement of any components that cannot
be removed or happen to be damaged.
Anything that is not explicitly provided for in the installation manual is not allowed. The operator’s proper operation can only be guaranteed if
the information given is complied with. The Firm shall not be answerable for damage caused by failure to comply with the instructions featured
herein.While we will not alter the product’s essential features, the Firm reserves the right, at any time, to make those chan-ges deemed opportune
to improve the product from a technical, design or commercial point of view, and will not be required to update this publication accordingly.
Preamble
SAFETY INSTRUCTIONS
1
APPLICATION DOMAIN
2
WIRING
WARNING!
For connection to the mains power supply, use a multicore cable with a cross-sectional area of at least 4x1.5mm2 of the kind provided for by
the regulations mentioned above (by way of example, type H05 VV-F cable can be used with a cross-sectional area of 4x1.5mm2). - Wires must be secured with
additional fastening near the terminals (for example, using cable clamps) in order to keep live parts well separated from safety extra low voltage parts.- During
installation, the power cable must be stripped to allow the earth wire to be connected to the relevant terminal, while leaving the live wires as short as possible.
The earth wire must be the last to be pulled taut in the event the cable’s fastening device comes loose.
WARNING!
safety extra low voltage wires must be kept physically separate from low voltage wires.Only qualified personnel (professional installer) should
be allowed to access live parts.
1/6