R D 3 0 1 U s e r m a n u a l
Cable length: 1.5m. (4.9 ft.)
70(2.736)
Tab size 6.3 x 0.8
50(1.968)
70(2.736)
1
(CD7018)
62(2.441)
13(0.492)
Ground stud 4M x 12
Nut M4
Washer DIN 6797 (2x)
2
NMEA Input
1.
Accepted messages (NMEA0183,version 2.30),
talker identifier is not processed:
- Depth &Draught
SDDPT,xxxx.x,xxxx.x,xxxx.x <Cr><Lf>
(used by EA400 and EA600)
- Depth below transducer
SDDBT ,xxxx.x,f,xxxx.x,M,xxx.x,F)
- Depth below transducer by EN 250
proprietary sentence
shown to the left
(only for EN 250)
PANEL MOUNTING
A
Make a cut out in the Panel
(5)
: 125 x 125 mm.
B
Remove the mounting bracket
(1)
.
C
Unscrew the 4 screws in the frame
(3)
(one in each corner)
and remove the frame.
D
Put the Monitor
(4)
in the cut out and mark the 4 center-
points for the drill in the Panel
(1)(2)
. (The drilling holes
diam. depends on thickness and material in the Panel).
E
Use appropriate bolts with diameter 2.9 mm. Length
depends on the Panel thickness.
F
Finally put on the frame
(3)
. Make sure that the screw
heads correspond with the cut outs in the frame.
Before fixing the monitor
(4)
in the cut out area in console
(1)(2)
, apply sufficient amount of water sealant compound
between the monitor
(4)
and console
(1)(2)
. Before the
frame
(3)
is remounted, apply sufficient amount of water
sealant compound in the inner area of the frame and on the
edges of the monitor
(4)
, to ensure that water can not pen-
etrate into the monitor
(4)
. The front panel of the monitor
is waterproof.
Transducer location *
Echo sounder channel number (0-99)
Bottom echo strength (0,9)
Maximum range scale in use, meters
Offset from transducer, meters
Water depth relative to transducer, meters
* Text string, indicating transducer position: FWD/AFT/PORT/STB.
If position is not preset by operator, empty field is provided.
$PSKPDPT,x.x,x.x,x.x,xx,xx,c-c*hh<CR><LF>
(Cd7019)
Some remote displays may have the text “REMOTE DISPLAY” instead of
“RD301” on the front.
S
ft
M
F
RD301
144 [5,669]
144
[5,669]
100(3.937)
5
S
RD301
F
ft
M
132,5 [5,217]
125
[4,921]
Cut out
The drilling holes diam. depends on thickness and material in the Console.
Hole diam. %%C4.0 (0.157)
125 [4,921]
4
3
96
[3,780]
Mounting bracket
857-164821aa
2