Simrad RD 301 Instruction Manual Download Page 3

R D 3 0 1   U s e r   m a n u a l

Cable length: 1.5m. (4.9 ft.)

70(2.736)

Tab size 6.3 x 0.8

50(1.968)

70(2.736)

1

(CD7018)

62(2.441)

13(0.492)

Ground stud 4M x 12

Nut M4

Washer DIN 6797 (2x)

2

NMEA Input

1. 

Accepted messages (NMEA0183,version 2.30), 
talker identifier is not processed:

- Depth &Draught 

SDDPT,xxxx.x,xxxx.x,xxxx.x <Cr><Lf> 
(used by EA400 and EA600)

- Depth below transducer 

SDDBT ,xxxx.x,f,xxxx.x,M,xxx.x,F)

- Depth below transducer by EN 250 

proprietary sentence 

shown to the left

 

(only for EN 250)

PANEL MOUNTING

A

 Make a cut out in the Panel 

(5)

: 125 x 125 mm.

B

 Remove the mounting bracket 

(1)

.

C

 Unscrew the 4 screws in the frame 

(3)

 (one in each corner) 

and remove the frame.

D

 Put the Monitor 

(4)

 in the cut out and mark the 4 center-

points for the drill in the Panel 

(1)(2)

. (The drilling holes 

diam. depends on thickness and material in the Panel).

E

 Use appropriate bolts with diameter 2.9 mm. Length 

depends on the Panel thickness.

F

 Finally put on the frame 

(3)

. Make sure that the screw

heads correspond with the cut outs in the frame.

Before fixing the monitor 

(4)

 in the cut out area in console 

(1)(2)

, apply sufficient amount of water sealant compound 

between the monitor 

(4)

 and console 

(1)(2)

. Before the 

frame 

(3)

 is remounted, apply sufficient amount of water 

sealant compound in the inner area of the frame and on the 
edges of the monitor 

(4)

, to ensure that water can not pen-

etrate into the monitor 

(4)

. The front panel of the monitor 

is waterproof.

Transducer location *

Echo sounder channel number (0-99)

Bottom echo strength (0,9)

Maximum range scale in use, meters

Offset from transducer, meters

Water depth relative to transducer, meters

* Text string, indicating transducer position: FWD/AFT/PORT/STB.

If position is not preset by operator, empty field is provided.

$PSKPDPT,x.x,x.x,x.x,xx,xx,c-c*hh<CR><LF>

(Cd7019)

Some remote displays may have the text “REMOTE DISPLAY” instead of 

“RD301” on the front.

S

ft

M

F

RD301

144 [5,669]

144

[5,669]

100(3.937)

5

S

RD301

F

ft

M

132,5 [5,217]

125

[4,921]

Cut out

The drilling holes diam. depends on thickness and material in the Console.

Hole diam. %%C4.0 (0.157)

125 [4,921]

4

3

96

[3,780]

Mounting bracket

857-164821aa 

        2

Reviews: