Installation instructions 

20221370A

 3 

07.06.04

 

Electrical connections AP45/AP9MkII/AP9Mk3 

 

Figure 3  RC37 connection to AP45/AP9MkII-Mk3 

CALIBRATION 

Note ! 

When connected to an IS15 system as per instructions, use the IS15 calibration 
procedure. 

The calibration is carried out using the following procedure: 
1.

 

Switch on the autopilot to supply power to RC37, or use a separate switch if it is a 
stand alone compass. 

2.

 

Make two 360 degree turns to starboard within 5 minutes 
after switch on. Ensure smooth and slow movements. A 
minimum of roll and acceleration will give the best result. 
Use 60-90 seconds each turn and make sure the boat passes 
3 times through North (see figure). As soon as north is 
passed for the 3rd time, there will be a confirmation in the 
autopilot display (see below). 

 

Provided you have an AP45 with software version V1R3 or V1R4 (latest), you 
will read "Fluxgate compass compensated" in the info display when the 
calibration is completed. Press the alarm button to reset. There will be no 
confirmation in the display if the AP45 has a software revision earlier than V1R3.  

 

On AP9Mk2 and Mk3 there are no verification codes. However, when passing 
through north for the 3

rd

 time, the course display shows 045 for a short moment 

(less than a second). 