For more details, refer to operator manuals:
R2009/R3016_OM_EN_988-10949-00X and R3016-12U/6X_OM_EN_988-10911-00X.
Alert notifications
When an alert is triggered, the alert appears in the Alerts panel. Alarms and warnings remain in the Alerts panel until the reason for
the alarm/warning is removed and the alarm/warning has been acknowledged.
The alerts are displayed in a sorted order. The sort order is the severity (i.e. alarm before warning), then age.
When a rectified alert is acknowledged it will disappear from the Alerts panel.
It is not possible to acknowledge cautions. They will disappear from the system when they are rectified and therefore only have an
active state.
Responsibility transferred is the process used to inform functions, sensors and/or sources that after evaluation the INS with its system
knowledge has taken the responsibility in order to reduce the number of high priority alerts.
Alert type
Icon
State
Indication
Alarm
Active -
not acknowledged,
not silenced
Flashing symbol and descriptive text
Audible signal
Active -
not acknowledged,
silenced
Flashing symbol and descriptive text
No audible signal
Active -
acknowledged
Steady symbol and descriptive text
No audible signal
Active -
responsibility transferred
Steady symbol and descriptive text
No audible signal
Active -
not acknowledged
Flashing symbol and descriptive text
No audible signal
Warning
Active -
not acknowledged,
not silenced
Flashing symbol and descriptive text
Audible signal
Active -
not acknowledged,
silenced
Flashing symbol and descriptive text
No audible signal
Active -
acknowledged
Steady symbol and descriptive text
No audible signal
Active -
responsibility transferred
Steady symbol and descriptive text
No audible signal
Active -
not acknowledged
Flashing symbol and descriptive text
No audible signal
Caution
Active
Steady symbol and descriptive text
No audible signal
*988-10951-002*