![Simrad PI Installation Manual Download Page 34](http://html.mh-extra.com/html/simrad/pi/pi_installation-manual_1278767034.webp)
Simrad PI Catch monitoring system / Trawl hydrophone
28
851--164472 / Rev.B
Cable gland installation for steel hulls
The cable gland kit for steel vessels is included with standard
deliveries. The drawing shows a single hydrophone, but
normally a typical installation includes two hydrophones with
respective cables spliced in a junction box and run to the
wheelhouse in a conduit.
Cable gland for steel hull
vessels.
(A) = Steel conduit
(B) = Stuffing tube, DNV
approved carbon steel st52.3
(C) = Washers, 24 x 8 x 2 mm
(D) = Rubber gasket
(E) = Packing nipple. Make
sure that you do not damage the
hydrophone cable by tightening
the packing nipple too hard!
(F) = Cable to the PI Operator
unit (or a junction box)
The gland gland kit includes all
of the necessary parts needed to
install the unit excluding
screws.