MARIS ECDIS900 Installation Manual
INSTALLATION, POWER
The SIS4000-Mk2 accepts 10-40 VDC. Note the polarity.
From AC/DC power supply, it is mandatory that the AC power comes from the same source as
for the computer.
From emergency or radio batteries, take the power from the same source that feeds the main
navigational GPS.
CONFIGURATION
Please read the Annex SIS4000-Mk2 installation and configuration.
E
LECTRICAL
I
NSTALLATION KIT
For each workstation, an installation kit is available. This kit contains approved ToughCat
network cable, approved power cable, power strips, cable ties and markers and much more.
See Annex Installation kits for more information.
Note that the network cable requires special RJ45 connectors, which are also included.
Failure to use approved items may lead the class society or the flag state to reject the
installation and deny the final approval.
Do not get caught in the net – use the installation kit!
AC P
OWER
MARIS standardize on 220VAC 50/60 Hz.
Plugs and power strips are in accordance with European standard.
On ships with 110VAC and specifically Japanese build ships with 100VAC, MARIS recommends
an UPS is installed. Refer to the Annex More about UPS for the correct types.
Power must be taken from the Navigational Equipment Switchboard or from the Emergency
Switchboard. Two (2) circuit breakers are needed, one for the monitoring station and one for
the planning station (IMO requirement).
Summary of Contents for Maris ECDIS900
Page 1: ...ENGLISH Maris ECDIS900System Installation Manual www navico commercial com ...
Page 40: ...Page 40 MARIS ECDIS900 Installation Manual ECDISMK15 MECHANICAL DRAWINGS ...
Page 41: ...Page 41 MARIS ECDIS900 Installation Manual DIMENSIONAL DRAWINGS FOR 19 TERMINAL LAYOUT FOR 19 ...
Page 42: ...Page 42 MARIS ECDIS900 Installation Manual DIMENSIONAL DRAWINGS FOR 24 TERMINAL LAYOUT FOR 24 ...
Page 44: ...Page 44 MARIS ECDIS900 Installation Manual HATTELAND MONITORHD26T21 ECDIS900 PCMK5 ...
Page 63: ......