INSTALLING SOFTWARE DONGLE
Check the current version of ECDIS900. If older than 4.5.4.77, use Windows Add/Remove
programs and uninstall ECDIS900, C-Map Professional SDK Runtime and eToken PKI Client.
Note that C-Map services must be stopped before they can be uninstalled. Restart the
computer.
Install ECDIS900 and select Do not use hardware Protection as shown here:
Notes.
New installation:
The number 3409 is an example only and it
must be replaced by the actual ID number as
found on the ECDIS Sentinel dongle. Remove
the tick mark in the box.
Upgrade:
The number is filled out automatically. Set a
tick mark in the box.
Continue installation by following instructions on screen.
Check that C-Map Professional SDK Runtime has been successfully installed.
M
ORE ABOUT
UPS
The UPS is manufactured in two types.
•
The change-over type.
•
The always-on type.
The change-over type
The change-over type has one advantage – it is cheap. It is manufactured in large quantities
and the quality and stability are often doubtful.