Description of telegrams and remote control
P3404E/A
9
S1
contains the mean S
v
per ping inside each active main
layer and the effective thickness of the layer: header, time
tag, number of active layers, layer number, mean S
v
[dB],
effective thickness [meter] etc. Note that S
v
values smaller
than -99.9 dB causes $$$.$ to be printed.
Q1
contains main and bottom echogram values in dB as
ASCII text. This long telegram should only be used for
special studies since the capacity of the serial line is
limited and overflows even at a moderate ping rate. The
binary mode is a lot more efficient (See echogram Q1 in
The Disk Storage chapter).
1.5 LOG-BASED OUTPUT TELEGRAMS
Examples of log-based output telegrams:
VL,10030740,930523,1834.015
<CR><CR><LF>
6
vessel log
LL,10031120,930523,1835.000, 1, 3,
<CR><LF>
6
layer settings
1,S, 10.0, 40.0, 1.0, 1, -80.0,
<CR><LF>
2,S, 40.0, 70.0, 1.0, 1, -80.0,
<CR><LF>
9,B, 20.0, 0.0, 5.0, 1, -80.0
<CR><CR><LF>
A1,10031120,930523,
<CR><LF>
6
integrator table
31,
<CR><LF>
121,
<CR><LF>
27E-1
<CR><CR><LF>
H1,10031120,930523,-50.0,
<CR><LF>
6
TS distribution table
818,38,38,17, 6, 1, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0,
<CR><LF>
73, 0, 0, 0, 0, 4, 4,11,16,14,10, 4,18,10, 3, 3, 3, 0, 1, 0, 0, 0, 0, 0, 0,
<CR><LF>
88, 0, 0, 0, 0, 3, 3, 9,16,11, 9, 5,18,12, 6, 2, 2, 1, 1, 0, 0, 0, 0, 0, 0
<CR><CR><LF>
VL
reports that a log pulse has been detected and contains
header, time tag, date, updated log distance [nm].
LL
is output every log interval and contains the current layer
settings: header, time tag, date, current log distance [nm],
super layer, number of active layers, layer number, layer
type (S, B or P), upper depth [meter], lower depth [meter],
margin distance [meter], the value 1, S
v
threshold value
[dB] etc.
A1
is output every log interval and contains the integration
results within each layer: header, time tag, date, first
active main layer [m
2
/nm
2
], second active main layer
[m
2
/nm
2
] etc. Note that a special exponential format is
used for representing very small and very large numbers.
Summary of Contents for EY500
Page 1: ...6LPUDG 3RUWDEOH VFLHQWLILF HFKR VRXQGHU...
Page 2: ......
Page 20: ...System familiarization 14 P3400 B...
Page 44: ...Operation 10 P3402 C Blank page...
Page 52: ...Operation 18 P3402 C Blank page...
Page 53: ...Simrad EY 500 P3402 C 19 Figure 4 Scope plot showing 300 samples of transceiver data...
Page 140: ...Simrad EY 500 20 P3403E A...
Page 164: ...Maintenance Figure Transceiver with PC...
Page 165: ...500 senes echo sounders Vlew transceiver...
Page 166: ...Maintenance Figure interconnection...
Page 170: ...Maintenance Figure...
Page 174: ...Maintenance...
Page 179: ...500 series portable echo sounders Figure tra nsce i ver...
Page 183: ...500 series echo sounders power...
Page 185: ...500 series portable echo sounders...
Page 224: ...Calibration 22 P2260 E Figure 8...
Page 225: ...Simrad EK 500 EY 500 P2260 E 23 Figure 9...
Page 232: ...Calibration 30 P2260 E Blank page...
Page 234: ...Calibration 32 P2260 E Blank page...
Page 239: ......
Page 240: ......
Page 241: ......
Page 242: ......
Page 243: ......
Page 244: ......
Page 245: ......
Page 246: ......
Page 247: ......
Page 248: ......
Page 249: ......
Page 250: ......
Page 251: ......
Page 252: ......
Page 253: ......
Page 254: ......
Page 255: ......
Page 256: ......
Page 257: ......
Page 258: ......
Page 259: ......
Page 260: ......