Type
Icon
State
Indication
Warning
Active - not acknowledged,
not silenced
•
Descriptive text
•
Audible signal
Active - not acknowledged,
silenced
•
Descriptive text
•
No audible signal
Active - acknowledged
•
Descriptive text
•
No audible signal
Rectified - not acknowledged
•
Descriptive text
•
No audible signal
Acknowledging a message
An alert dialog showing a single message have one or two options for acknowledging the
message:
•
ACK / Acknowledge
Sets the alarm state to acknowledged, meaning that you are aware of the alarm condition.
The siren/buzzer stops and the alarm dialog is removed.
However, the alarm remains active in the alarm listing until the reason for the alarm has
been removed.
•
Silence
Mutes the siren locally (for 30 seconds) for all units in the same network alarm group. The
alert dialog remains on the display.
There is no time-out on the alarm message or siren. They remain active until you
acknowledge the alarm or until the reason for the alarm is removed.
Alert dialogs
Active alerts
List of all active alerts.
The alert system
| AP70 MK2 Operator Manual