42 | Technical specifications
Dynamic Performance:
With random excitation of ±10° at max. 1 Hz:
Heading error <5°
With heading step input of 90° at a rate of 10°/s:
Heading error 10 sec after turn <5°
Output signal: ...................................................... PGN127250
NMEA2000 compliant
Figure 4-6 FC40 Fluxgate Compass - Dimensions
4.6
RC42 Rate Compass
Dimensions:...............................Same as FC40. See Figure 4-6
Weight: ..........................................................0,9 kg (2,0 lbs)
Material:...........................................................Off-white ABS
Environmental Protection:................................................ IP56
Temperature range:
Operation:....................... 0 to +55 °C (+32 to + 130 °F)
Storage:........................ –30 to +70 °C (–22 to +158 °F)
Supply and interface: ....................................8-16V via SimNet