background image

 

WinFrog User’s Guide - Appendix C - Output/Simrad 301 DP 

Page 4 of 7 

WINFROG VEHICLE TEXT WINDOW > CONFIGURE VEHICLE DEVICES > DEVICE 
> EDIT OPTIONS: 
The OUTPUT,SIMRAD301 DP, DP OUTPUT data item is added to the vehicle with the 
DP system in use. This vehicle should also be tracking the Survey Line for which you 
intend to send the relevant line data, to the DP system. If a Survey Line is not enabled, 
or the device is not added to the vehicle, no line segment data will be transferred. The 
dialog box below will appear when you attempt to configure the device, and send data 
to the DP. This will not change until a tracking line is enabled and the device is added to 
the vehicle. 
 

 

 
When the SIMRAD301 DP, DP OUTPUT item is edited from the Configure Vehicle 
Devices dialog box, the Configure DP Output dialog box appears. The Position Source 
and the Position Offset tabs must be configured. These items configure the vehicle 
position output as described in the type 450 record under Configuration Details. 
 

 

 

Position Source: 
Three items need to be configured on this tab: Data Type Control, Graphics, and 
Data Source Control.  

Summary of Contents for 301 DP

Page 1: ...ts from positioning systems gyrocompasses wind speed and direction monitoring equipment and any other sensors which can assist with the automatic positioning of the vessel Commands to the thrusters ca...

Page 2: ...gure Device Survey Line Enter in the survey line segments of the active survey line in the Start and End boxes then select the Send Segments checkbox When the OK button is clicked to exit the dialog b...

Page 3: ...the Simrad 301 as in house tests show that the start segment may have to be 1 Is the end segment the start segment Is the start segment the last line node Is the end segment the last line node Is the...

Page 4: ...ata will be transferred The dialog box below will appear when you attempt to configure the device and send data to the DP This will not change until a tracking line is enabled and the device is added...

Page 5: ...ry positioning sensor data will be used If either the Unfiltered Sensor Derived CRP Position or the Unfiltered Sensor Position is chosen in the Data Type Control then the positioning sensor can be cho...

Page 6: ...performed under the supervision of the vessels electrician or other qualified person as designated by the Captain After interfacing all systems should be thoroughly checked prior to operation First c...

Page 7: ...atitude and longitude of the vessel position as described in the Config DP Output Window 484606 33122696 5120733 25075906 are UTM grid coordinates for the Waypoint being tracked under Setup Waypoint T...

Reviews: