DISPLAY
Type:
7-segment, red LED
Height:
0.56” (14.2mm)
Decimal Point:
4-position programmable
internally or at terminal block J112
Overrange indication:
most significant digit =
“1”; other digits blank
Polarity:
Automatic, with “-” indication,
“+” indication implied
POWER REQUIREMENTS
AC Voltages
: 120 or 220VAC, ±10% 50/60Hz
DC Voltages:
9-32VDC; 9V -1% and 32+1%
Power Consumption:
2VA
ACCURACY @25
°
C
±0.5% of reading ±35 count
ENVIRONMENTAL
Operating Temperature:
0 to 55ºC
Storage Temperature:
-10 to 60ºC
Relative Humidity:
0 to 85% non-condensing
Temperature Coefficient:
(±0.05% of input ±0.5 count)/ºC
Warm-up Time:
Less than 15 minutes
Response Time:
Less than 1 second
NOISE REJECTION
NMRR:
60dB, 50/60Hz
CMRR:
(w/1kΩ unbalanced @60Hz):
90dB min.
ANALOG TO DIGITAL CONVERSION
Technique:
Dual slope integration
Rate:
2.5 samples per second, nominal
MECHANICAL
Bezel:
3.78” x 1.89” x .51” (96 x 48 x 13mm)
Depth:
2.94” (74.7mm)
Panel Cut-out:
3.62” X 1.77” (91.9 x 45mm 1/8 DIN)
Case Material:
94V-1, UL rated Noryl®
Weight:
9.0oz (255.1g)
INPUTS: AC
Input
Range
Display
Resolution
Input
Impedance
Maximum
Overload
200mV
10µV
>100MΩ
100V
2V
100µV
>1MΩ
250V
20V
1mV
>1MΩ
250V
200V
10mV
>1MΩ
250V
Input Signal:
Connect the signal to be monitored to the IN HI and IN
LO terminals. These are terminals #1 and #2.
Supply Power:
Connect the power to terminals #11 and #12. Note
that if AC power is applied, terminal #11 is for neutral, and terminal
#12 is for hot. If DC power is used, terminal # 11 is for -DC, and #12
is for +DC.
Display Hold:
This feature allows you to hold the displayed value in-
definitely. A remote switch or computer, etc. can be used to activate
this feature. To activate feature, short pins 3 and 4 (HOLD and DIG
GND). This connection must be kept isolated from other circuitry.
To hold multiple units, separate poles of the switch must be used to
maintain the isolation.
These instruments are designed for maximum safety to the operator
when mounted in a panel according to instructions. They are not to
be used unmounted or for exploratory measurements in unknown
circuits.
Specifications
Decimal
Point
Jumper
Position at J107
1.9999
A (DP 1)
19.999
B (DP 2)
199.99
D (DP 3)
1999.9
E (DP 4)
Decimal Point Selection
Wiring Diagram
Voltage Range Selection
All Falcon Indicators are configured initially per the customer specified
part number. Range changes can easily be accomplished as follows:
Disconnect power and pop the front bezel off with a small screwdriver,
taking care to keep the gaskets in place. Unscrew the main board from
the case with a Phillips head screwdriver, and slide the main board out.
Note: If a new range is selected, the calibration procedure must also be
performed. Only perform this section if a different function or range is
required.
Input
Range
J105
PJ
J106
PJ
J101
PJ
J102
PJ
J103
PJ
JU101
Jumper Position
200mV
C
NO
NO
YES
NO
V
2V
B
NO
NO
NO
YES
V
20V
D
NO
NO
NO
YES
V
200V
E
NO
NO
NO
YES
V
Note:
JU101 and JU102 are hard wire jumpers and can be removed by
cutting them. Resoldering the JU jumpers is not recommended. If this is
required, or if a function is to be changed from volts to current, Simpson
recommends returning the Falcon to the factory or an Authorized Service
Center. After moving the jumpers to the desired location, put the Falcon
back together and install in your panel, or proceed to calibration.
Note:
See diagram in Decimal Point Selection panel for J106 jumper
location.
Example: 200mV input
J112
1
2
3
4
5
6
7
8
9
10 11 12
IN LO
IN HI
HOLD
DIG GND
DP
1
DP
2
DP
3
DP
4
+ EXC
- EXC AC GND
AC LO - DC
AC HI + DC
1
2
3
4
5
6
7
8
9 10 11 12
IN LO
IN HI
HOLD
DIG GND
DP
1
DP
2
DP
3
DP
4
+ EXC
- EXC AC GND
AC LO - DC
AC HI + DC
Main Board
Decimal
Point
Connect
1.9999
DIG GND to DP1
19.999
DIG GND to DP2
199.99
DIG GND to DP3
1999.9
DIG GND to DP4
From terminal block J112:
The decimal point can be set from the
rear screw terminal block J112. Connect the appropriate DP point
(DP 1,2,3,4) to the DIG GND terminal. Internal jumper (J107) must be
removed.
E
C
A
D
B
J107
Jumper shown in
‘A’ position