Simply Automated UMI Installation Download Page 2

Input/Output Module 

Model UMI 

Simply Automated, Incorporated.   

www.Simply-Automated.com

 

    

800-630-9234 

452-0003-0001 Rev. F     November 30, 2011 

WIRING DIAGRAMS 

The UMI module can accept up to 3 inputs and 2 outputs.  Each input has 
different wiring configurations, depending upon the type of input being 
sensed: 

 

Input #1 can accept a phoneline (for ring detect), 120VAC (e.g. 
motion sensors), or a low-voltage input. 

 

Input #2 can accept a dry contact closure or a low-voltage input. 

 

Input #3 can accept a current input (wired in series with a 
doorbell switch), a dry contact closure, a low-voltage input, or a 
line audio input with a choice of two trigger thresholds. 

 
 

Low Voltage SSR (Solid State Relay) Outputs  

Output #1

:  Connect wires in series with a source* of low-voltage 

power and the load to terminals 1 and 2. 

 

Output #2

:  Connect wires in series with a source* of low-voltage 

power and the load to terminals 3 and 4. 

 
 
 
 
 
 
 
 
 

Connect wires to a device that accepts a contact input.  If a voltage 
signal is required, wire a low voltage source in series.  Polarity of the 
source is dependent on the load.  When enabled, the momentary 
closure setting is approximately 1 second (default is disabled). 
 
* Source may not be required by load.  Check to confirm proper 
source connection. 

 
 
Telephone Ring or 120VAC (Motion Sensor) Detect Input 

Input #1

:  Tip and Ring (or Hot and Neutral, respectively) connect to 

terminals 5 and 6. 

 

 
Contact Closure Inputs 

Input #2

:  Connect wires to terminals 9 and 10. 

 

 

 

 
Input #3

:  Connect wires to terminals 15 and 16. 

 

 

Voltage Sense (triggers on a 4-5VAC/DC threshold) 

Input #1

:  Connect wires to terminals 6 and 7. 

 

Input #2

:  Connect wires to terminals 8 and 9. 

 

Input #3

:  Connect wires to terminals 14 and 15. 

 

 

Doorbell Detect

 (current sense, triggers at around a 200mA threshold) 

900mA max. 

Input #3

:  Wire in series, preferably at transformer, connecting wire 

from doorbell switch to terminal 14 and connecting wire from terminal 
13 to the transformer. 

 

 

 

Audio Sense (-30dBV or -10dBV audio sense) 

Input #3

:  From line audio source, connect center conductor to 

terminal 11 for -30dBV or terminal 12 for -10dBV.  Connect the shield 
to terminal 13. 

 

Rating: 60VDC/42VAC @ 400mA max. 

Rating: 60VDC/42VAC @ 400mA max. 

Rating:

 30Vrms/DC

 

Rating: 

30Vrms/DC

 

Rating: 

30Vrms/DC

 

Rating: 

30Vrms/DC

 

Rating: 30Vrms/DC 