SimpliFire • SF-BI30-EB, SF-BI36-EB • 2040-980 Rev. F • 4/20
8
4
4
INSTALLATION
A. Selecting Appliance Location
When selecting a location for the appliance it is important to
consider the required clearances to walls (see Figure 4.1).
WARNING! Risk of Fire or Burns!
Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be locat
-
ed out of traffic and away from furniture and draperies.
NOTICE:
Illustrations reflect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
D2
1/2 in.
1/2 in.
D3
D1
W2
H1
W1
Figure 4.1 Clearance Requirements
This product can be built into new construction or an exist-
ing factory-built fireplace.
Reference Sections 4.A - 4.D for
specific information for your installation.
MODEL
W1
H1
D1
W2
D2
D3
(Table in Inches)
120V
240V
SF-BI30-EB
32
29
31
11-5/8
47-5/16
33-1/2
23-11/16
SF-BI36-EB
38
33-11/16
35-11/16
11-5/8
55
38-29/32
27-1/2
MODEL
(V)
(W)
REMOTE
(A)
SF-BI30-EB
120/208/240
1400/2100/2800
Yes
11.7/10.1/11.7
SF-BI36-EB
120/208/240
1400/2100/2800
Yes
11.7/10.1/11.7
ELECTRICAL SPECIFICATIONS: