background image

VSH SUPER 

Compression Fittings

Metallic Sealed

Technical Information 

|

 Installation Instructions

EN

Areas of application

  Suitable for domestic water systems according to 

  DVGW W 534 and DIN 1988, pipe materials:  
  Copper pipe DIN EN 1057 and stainless steel pipe  
  DIN EN 10312, DVGW GW 541 dimensions 12 to 42 mm,  
  certification no. DW-8511AQ2006

  Suitable for gas installations according to DVGW  

  worksheet G 260/I the 2nd gas type, according to  
  DIN 3387 (removable pipe connections for metal gas  
  pipes / smooth pipe connectors) and in accordance  
  with DVGW G 600, TRGI 2008, pipe material: Copper  
  pipe according to DIN EN 1057 and DVGW GW 392,  
  semi-hard (R250), dimensions 12 to 22 mm, 
   certification no. NG-4502BL6101 (use support sleeve)

  According to DIN 1988 and DVGW worksheet G 600,  

  TRGI 2008 VSH SUPER compression fitting made of  

 

  brass may be  installed under plaster. 

 

Under certain conditions brass components (including 
nuts, clamp rings of VSH SUPER compression fittings) can 
be affected by stress corrosion cracking. This special type 
of corrosion leads to component failure.
To prevent this, such systems must not be exposed to  
ammoniac or chlorinated environments (e.g. stables, 
swimming pools). Furthermore, no condensate should 
form on the fittings. Particularly in the areas where fittings 
and pipes are continuously cold must be fully and non- 
diffusively equipped with closed cell insulation to reliably 
prevent condensation. The insulation used and all other 
adhesives, additives and coatings have to be absolutely 
free of chlorine, ammoniac and nitrite. 
If in doubt, a clearance certificate must be obtained from 
the manufacturer.

The prescribed processing instructions with information 
concerning the correct installation of the union nuts must 
be observed.
When using VSH SUPER compression fittings in gas systems, 
no oil or grease may be used to facilitate assembly.   
Danger of explosion! Only aids authorized in accordance 
with the relevant DVGW guidelines and with appropriate 
DVGW registration are permitted.
The reuse of a previously used fittings is only permitted 
with a new seal set.

Important Installation Notice!

Reviews: