VSH SUPER
Compression Fittings
Metallic Sealed
Technical Information
|
Installation Instructions
EN
Areas of application
■
Suitable for domestic water systems according to
DVGW W 534 and DIN 1988, pipe materials:
Copper pipe DIN EN 1057 and stainless steel pipe
DIN EN 10312, DVGW GW 541 dimensions 12 to 42 mm,
certification no. DW-8511AQ2006
■
Suitable for gas installations according to DVGW
worksheet G 260/I the 2nd gas type, according to
DIN 3387 (removable pipe connections for metal gas
pipes / smooth pipe connectors) and in accordance
with DVGW G 600, TRGI 2008, pipe material: Copper
pipe according to DIN EN 1057 and DVGW GW 392,
semi-hard (R250), dimensions 12 to 22 mm,
certification no. NG-4502BL6101 (use support sleeve)
■
According to DIN 1988 and DVGW worksheet G 600,
TRGI 2008 VSH SUPER compression fitting made of
brass may be installed under plaster.
Under certain conditions brass components (including
nuts, clamp rings of VSH SUPER compression fittings) can
be affected by stress corrosion cracking. This special type
of corrosion leads to component failure.
To prevent this, such systems must not be exposed to
ammoniac or chlorinated environments (e.g. stables,
swimming pools). Furthermore, no condensate should
form on the fittings. Particularly in the areas where fittings
and pipes are continuously cold must be fully and non-
diffusively equipped with closed cell insulation to reliably
prevent condensation. The insulation used and all other
adhesives, additives and coatings have to be absolutely
free of chlorine, ammoniac and nitrite.
If in doubt, a clearance certificate must be obtained from
the manufacturer.
The prescribed processing instructions with information
concerning the correct installation of the union nuts must
be observed.
When using VSH SUPER compression fittings in gas systems,
no oil or grease may be used to facilitate assembly.
Danger of explosion! Only aids authorized in accordance
with the relevant DVGW guidelines and with appropriate
DVGW registration are permitted.
The reuse of a previously used fittings is only permitted
with a new seal set.
Important Installation Notice!