background image

 

 

Fiber Optic Modem 
Installation Instructions  

579-831 
Rev. H 

 

Summary of Contents for 4100-6072

Page 1: ...Fiber Optic Modem Installation Instructions 579 831 Rev H...

Page 2: ......

Page 3: ...lication and are subject to change without notice Simplex and the Simplex logo are trademarks of Tyco International Ltd and its affiliates and are used under license All other logos and product names...

Page 4: ...und to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipme...

Page 5: ...ications 15 Analog Audio Riser Wiring Specifications 17 Enhanced Analog Audio EAA Riser Wiring Specifications 19 Digital Audio Riser Specifications 21 RUI Wiring Specifications 22 Fiber Modem Audio Ex...

Page 6: ...work 43 Hub Configuration Analog Audio 44 Hub Configuration Digital Audio 45 Interconnected Loop and Star Configurations Overview 46 Interconnected Loop and Star Configurations 4120 Network 47 Interco...

Page 7: ...eneric A Generic modem is any modem that is not a Head End or Tail End modem In a Class B configuration all modems are generic Head end A Head End modem is a modem with an electrical connection to the...

Page 8: ...is unsupervised Excludes the usage of the DAR interface for the Digital Audio Riser because the DAR interface is used as the EAA channel The Modem can replace either one or two wired connections betwe...

Page 9: ...ANNEL 2 CONFIGURATION FIBER OPTIC ST CONNECTOR 24V POWER CONNECTION OPTIONS Fiber transceiver EXPANSION HEADER TB2 P6 P5 P3 SW1 SW2 SW3 SW4 LED2 LED1 LED4 LED5 LED3 P7 P8 P10 P9 P2 LED6 LED8 LED10 LED...

Page 10: ...Optic Modem with Expansion Cabinet Assembly Red Expansion to 4100ES 4100U 4100 4010 4010ES or 4020 4190 9022 Fiber Optic Modem with Expansion Cabinet Assembly Beige Expansion to 4100ES 4100U 4100 401...

Page 11: ...5 dB Connectors No limit specified Multi Mode Fiber 5 000 feet 1 6 km maximum 50 um or 62 5 um GRIN Maximum total attenuation 6 dB Connectors Three or less in addition to the connections to the modems...

Page 12: ...tions SW1 RUI 4120 Network Configuration Settings RUI Notes 1 Set this switch to ON if the Modem is part of a Class A RUI loop Set this switch to OFF if the Modem is wired Class B 2 Set this switch to...

Page 13: ...Head End or Tail End Modem then always set the switch to ON 3 Set this switch to ON if the Modem is a Head End or Tail End Modem Set to OFF if the Modem is isolated from the Audio Controller card via...

Page 14: ...if the Modem is wired Class B 2 Set this switch to ON if the Modem is on the primary side of a Modem pair Set this switch to OFF if the Modem is on the secondary side of a Modem pair If the Modem is a...

Page 15: ...p X Analog Audio Analog Riser Output Level Channel 2 0 707 Vrms X Analog Riser Output Level Channel 2 Standard 10 Vrms Table 9 Analog Audio Input Level Jumper Placements Jumper Description Position 1...

Page 16: ...or B configurations or directly to the amplifier s output in Class A only Refer to Figure 12 for wiring details of the expansion board All wiring from the expansion board must be close nippled Figure...

Page 17: ...nks See Figure 3 The Remote Expansion Cabinet is required when the modem is used with a 4010 4010ES or 4020 Network Communications only application When the modem is used with a 4100 4100U or 4100ES s...

Page 18: ...FIBER MODEM LEFT PORT ASSEMBLY PART OF 4100 9015 9016 ASSEMBLY 4190 9017 FIBER MODEM ASSEMBLY RIGHT PORT OPTIONAL REMOTE BOX MOUNTING BRACKET PART OF 4100 9015 9016 ASSEMBLY EXPANSION CABINET PART OF...

Page 19: ...o the bracket No standoffs are required For the two nylon supports posts shipped with the modem replace them with the posts shipped with the bracket Figure 5 Modem and Audio Expansion Board Mounting i...

Page 20: ...are required where the DAR 4120 Network and RUI wiring enters or exits a system box Except for the 4120 Network Right Port and the RUI X Link ferrite beads for all wires are supplied with their respec...

Page 21: ...18 AWG 0 8231 mm2 fire rated shielded twisted pair cable transmission distance is 10 000 Feet 3 048 meters with or without Suppressor 2081 9027 Using 24AWG 0 2047 mm2 twisted telephone cable transmiss...

Page 22: ...sted Unshielded Telephone Cable must not exceed a capacitance between conductors of 22pF per foot and not have a DC resistance greater than 25 6 ohms per 1 000 feet 305 meters When using twisted shiel...

Page 23: ...s of Modems in series using standard analog audio All wiring that leaves the building requires the 2081 9044 Overvoltage Protector at each entry or exit to the building Maximum wire distance 10 000 fe...

Page 24: ...4V IN 24C IN RUI RUI RUI XLINK RXLINK 24C EARTH RISER 1 RISER 1 RISER 1 XLINK RISER 1 XLINK 24 C EARTH RISER 2 RISER 2 RISER 2 XLINK RISER 2 XLINK 24V IN RUI ANALOG CH1 ANALOG CH2 SEE NOTE 2 BELOW TB1...

Page 25: ...S MODEM AUDIO OUT TO NEXT MODEM ANALOG AUDIO RISER WIRES DAR LEFT RIGHT 4120 NETWORK ANALOG RISER INTERFACE CARD CH1 CH2 PRI SEC PRI PRI PRI SEC SEC SEC SHLD SHLD TB1 TB2 INV NON INV EARTH 0V ISO2 0V...

Page 26: ...ng Specifications 11 10 13 12 15 14 4 5 2 3 6 7 8 9 16 1 Security Building Building A Building B Building J Building H Building G Building C Building D Building E Building F Building K E1 E3 E2 E4 E5...

Page 27: ...wiring is always within a system box or close nippled to a system box The DAR connection is always either to a Digital Audio Controller or a Digital Audio Riser Interface card All riser wiring is sup...

Page 28: ...tion for example a 2 500 foot 762 meter loop of copper could be connected to another 2 500 foot 762 meter of copper if the two loops were electrically isolated via fiber optic cable T tapping is not a...

Page 29: ...R SHIELD CONNECTIONS X LINK CONNECTIONS ARE NOT USED FOR ANY GENERIC OR ANY CLASS B MODEM SHIELD SHOULD BE CONNECTED TO 24 C ONLY IF THE CARD IS SET AS A DEFAULT RUI AND NOT WHEN SET AS A DEFAULT TIC...

Page 30: ...1 FIBER MODEM MODEM FIBER MODEM MODEM AUDIO EXPANSION CARD RUI 24V IN INPUT OUTPUT RISER 2 XLINK RISER 2 XLINK RISER 2 RISER 2 EARTH 24 C RISER 1 XLINK RISER 1 XLINK RISER 1 RISER 1 RISER 2 RISER 2 RI...

Page 31: ...ower supply SPS RPS XPS or MSS in the case of a 4010ES system If the connector on the power supply is occupied as may be the case in a Miniplex Transponder cabinet then connect the Modem power harness...

Page 32: ...26 4100U 4100ES 4010ES Figure 14 Modem Power Connections Connecting Power to the Modem Continued Where to Connect Power...

Page 33: ...are clean c The total attenuation and distance are within limits d If all of the above conditions are met and the Fiber Fault LED is still illuminated then it may be necessary to test the link using a...

Page 34: ...fault that s indicated by the fiber fault LED for any data error on the fiber In a properly operating fiber link momentary faults occur very rarely or never If the fiber fault LED illuminates frequen...

Page 35: ...ating modem s opposite port for example in on left out on right or vice versa 3 The network interface LEDs operate in the same way as those found on a network interface card that is the TX and RX LEDs...

Page 36: ...en the system enters degraded mode Analog Audio Riser Open open the riser wires or remove the End Of Line resistor Class B only Panel indicates an open if Class B If wired Class A enters degraded mode...

Page 37: ...nsion Board Figures A 21 and A 22 Multiple panels 4 in one building Multiple buildings 4 each with one panel Figure A 1 Internal Building or Multi Building Configuration Class A Style 7 or Style 6 App...

Page 38: ...RUI RUI Transponder 3 FIBER FIBER Modem TIC Modem SEC PRI RUI RUI Head End 1 SHIELD CPU Mother Board or RUI Card Modem SEC PRI RUI X LINK FIBER Modem FIBER RUI X LINK Transponder 2 SHIELD FIBER FIBER...

Page 39: ...erface Card Figure A 3 4120 Network Class A Style 7 Appendix Sample Configurations Continued 4120 Network excluding RUI Class A Style 7 Switch 1 5 OFF to enable the 4120 Network Interface SW1 6 4120 N...

Page 40: ...nd SW 2 1 SW 3 2 On riser interface it s not driving the copper the analog controller card is This is a generic modem not head or tail end SW 2 4 SW 3 4 Off ignored since it s a generic modem SW 2 3 S...

Page 41: ...2 6 On wired EAA connected SW 2 4 Off ignored since it s a generic modem SW 2 3 Off generic SW 2 2 On riser interface it s not driving the copper the analog controller card is This is a generic modem...

Page 42: ...dem FIBER Modem FIBER DAR DAR PRI SEC Digital Audio Riser Interface Modem FIBER Modem FIBER DAR DAR Figure A 6 Digital Audio excluding Analog Audio Channel 1 Class A Style 7 Appendix Sample Configurat...

Page 43: ...Class B Style 4 Appendix Sample Configurations Continued Internal Building or Multi Building Configuration Class B Style 4 Refer to the following pages for detailed implementation of the Internal Bui...

Page 44: ...re copper wiring exits the system box Note All switches not listed are set according to the application of their respective interface Head End Transponder Transponder Transponder RUI WIRES 2 FIBER FIB...

Page 45: ...ser 1 setting SW 2 2 Off Controller transmits analog riser Riser 2 setting SW 3 2 Off Controller transmits analog riser Riser 1 setting SW 2 2 On Riser interface receives analog riser Riser 2 setting...

Page 46: ...Transponder or remote node Transponder or remote node Transponder or remote node ANALOG AUDIO WIRES 2 ENHANCED AUDIO WIRES 2 FIBER FIBER FIBER FIBER SHIELD SHIELD SHIELD SHIELD Analog Audio Controller...

Page 47: ...em Modem Modem FIBER FIBER FIBER FIBER FIBER DAR WIRES 2 Modem PRI SEC FIBER DAR DAR DAR DAR DAR DAR Figure A 11 Digital Audio excluding Analog Audio Channel 1 Class B Style 4 Appendix Sample Configur...

Page 48: ...alog Audio and Digital Audio are illustrated on the pages that follow Figure A 12 Hub Configuration Appendix Sample Configurations Continued Hub Configuration Overview Required if analog audio interfa...

Page 49: ...R Fiber Modem L R Fiber Modem L R Fiber Modem L R NIC L R Fiber Modem L R Fiber Modem L R NIC L R Fiber Modem L R Fiber Modem Node 8 Remote Node Wire Fiber L R Fiber Modem Figure A 13 Hub Configurati...

Page 50: ...Off In this diagram the head end audio cabinet is not shown If Class A is required head and tail end modems require x link connections Figure A 14 Hub Configuration Analog Audio Appendix Sample Config...

Page 51: ...SEC RIC DAR DAR DAR DAR DAR DAR PRI SEC RIC PRI SEC RIC Fiber Modem Fiber Modem Fiber Modem Fiber Modem Fiber Modem Fiber Modem Fiber Modem Node 8 Remote Node Wire Fiber Figure A 15 Hub Configuration...

Page 52: ...loop star Figure A 16 Interconnected Loop and Star Configurations Appendix Sample Configurations Continued Interconnected Loop and Star Configurations Overview Required if analog audio interface is us...

Page 53: ...and Star Configurations 4120 Network Appendix Sample Configurations Continued Interconnected Loop and Star Configurations 4120 Network Settings for all modems in this configuration SW1 5 must be OFF e...

Page 54: ...etting SW 2 2 On Riser 2 setting SW 3 2 On Riser 1 setting SW 2 2 Off Riser 2 setting SW 3 2 Off Riser 1 setting SW 2 2 On Riser 2 setting SW 3 2 On Riser 1 setting SW 2 2 On Riser 2 setting SW 3 2 On...

Page 55: ...I SEC2 SEC1 RIC Fiber Modem DAR Node 12 Connection Figure A 19 Interconnected Loop and Star Configurations Digital Audio Appendix Sample Configurations Continued Interconnected Loop and Star Configura...

Page 56: ...ed IMS Configuration Appendix Sample Configurations Continued TrueSite Workstation TSW Notes Node 1 provides power and a cabinet for the modems connected to the IMS Optionally replace Node 1 with a tr...

Page 57: ...ISER2 RISER2 R1 XLINK R1 XLINK R2 XLINK R2 XLINK RISER1 OUT RISER2 OUT Audio Input Option Card IN Audio Controller Harness IN 4100 Audio Exp Modem Exp Hdr FIBER RISER1 RISER1 RISER2 RISER2 R1 XLINK R1...

Page 58: ...SER1 RISER2 RISER2 R1 XLINK R1 XLINK R2 XLINK R2 XLINK RISER1 OUT RISER2 OUT Audio Input Option Card IN R2 XLINK RISER 2 R1 XLINK RISER 1 Audio Controller Harness IN 4100 Audio Exp Figure A 22 Fiber M...

Page 59: ......

Page 60: ...2006 2011 SimplexGrinnell LP Specifications and other information were current as of publication and are subject to change without notice 579 831 Rev H...

Reviews: