background image

CellPipe

™ IAD 4A and 

CellPipe™ IAD 8T

Hardware Installation Guide

Part Number: 7820-0791-001

For software version 2.0

January 2001

Summary of Contents for CellPipe IAD 4A

Page 1: ...CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide Part Number 7820 0791 001 For software version 2 0 January 2001 ...

Page 2: ...ard nor Silicon Graphics makes any representations about the suit ability of this software for any purpose It is provided as is without express or implied warranty Berkeley Software Distribution BSD UNIX software copyright 1982 1986 1988 1993 The Regents of California All rights reserved Redistribution and use in source and binary forms with or without modification are permitted provided that the ...

Page 3: ...isXtend NetCare NetLight NetPartner OneVision Open Systems Innovations OpenTrunk P550 PacketStar PathStar Pinnacle Pipeline PMVision PortMaster SecureConnect Selectools Series56 SmoothConnect Stinger SYSTIMAX True Access WaveLAN WaveMANAGER WaveMODEM WebXtend and Where Network Solutions Never End are trademarks of Lucent Technologies Inc Advantage Pak Advantage Services AnyMedia Beyond Compare End...

Page 4: ...e following information available Active contract number product name model and serial number Software version Software and hardware options If supplied by your carrier service profile identifiers SPIDs associated with your line Your local telephone company s switch type and operating mode such as AT T 5ESS Custom or Northern Telecom National ISDN 1 Whether you are routing or bridging with your Lu...

Page 5: ... C Allow sufficient air circulation or space between units when installed in a closed or multiple rack assembly 6 Slots and openings in the cabinet are provided for ventilation To ensure reliable operation of the product and to protect it from overheating these slots and openings must not be blocked or covered Installation without sufficient airflow can be unsafe 7 Equipment mounted in a rack shou...

Page 6: ...quipment a type B plug or permanent connection must be used for connections to the main power supply 12 Before installing wires to the dc power terminal block verify that these wires are not connected to any power source Installing live wires that is wires connected to a power source is hazardous 13 Do not allow anything to rest on the power cord and do not locate the product where people will wal...

Page 7: ...nterface Use caution when installing or modifying telephone lines Avoid using equipment connected to telephone lines other than a cordless telephone during an electrical storm There is a remote risk of electric shock from lightning Do not use a telephone or other equipment connected to telephone lines to report a gas leak in the vicinity of the leak Warning To reduce the risk of fire communication...

Page 8: ......

Page 9: ...guring your communications software 2 Preparing to upgrade 3 Locating the software binary file s 3 Power supply 4 CellPipe IAD 4A 5 Connecting a CellPipe IAD 4A unit 5 Checking the activity of CellPipe IAD 4A status lights 6 Configuring a CellPipe IAD 4A unit 8 CellPipe IAD 8T 9 Connecting a CellPipe IAD 8T unit 9 Checking the activity of CellPipe IAD 8T status lights 10 Configuring a CellPipe IAD...

Page 10: ...s x CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide 10 100 LAN connector pinouts 15 T1 Connector pinouts 16 ADSL connector pinouts 16 FCC Regulations 17 FCC Part 15 Notice 17 IC CS 03 Notice 18 ...

Page 11: ...tware These are integrated access devices supporting both voice and data communications This Hardware Installation Guide provides information for connecting these new units to your computer For additional information refer to the CellPipe IAD User s Guide New CellPipe products 1 Lucent TURN UP 2 Serial connection 2 Configuring your communications software 2 Preparing to upgrade 3 Locating the soft...

Page 12: ...munication cable designed for connecting an external device from your computer to the CellPipe unit The cable must be a high speed cable that supports the hardware handshaking technique used by almost all recently manufactured modems The cable must have the appropriate connector for connection to a serial communication port on your computer and a DB 9 connector for connection to the TERMINAL port ...

Page 13: ...er second Specify 9600 Data bits Specify 8 Parity Specify None Stop bits Specify 1 Flow control Disable software flow control XON XOFF and if possible hardware flow control RTS CTS When you establish the connection the command line interface appears Preparing to upgrade Set up a TFTP server on the network that is accessible by your CellPipe unit prior to upgrading the software Also configure an IP...

Page 14: ...r configuration from a backup Extract and save the appropriate file to the TFTP boot directory from which you will upgrade your unit Power supply All CellPipe units are shipped with a power supply However European users need to purchase an additional wall outlet cable due to the regional variations in wall outlets Please check with your Sales Representative for the power supply and cables required...

Page 15: ...it supports asymmetrical transmission and receive downstream rates of 64 Kbps to 8 1 Mbps and upstream rates of 64 Kbps to 800 Kbps Connecting a CellPipe IAD 4A unit The CellPipe IAD box you receive contains the following items 1 CellPipe IAD unit 2 10BaseT Ethernet crossover cable yellow 3 ADSL WAN cable with RJ 11 modular plug connectors blue 4 Power supply 5 CellPipe IAD User s Guide 6 Hardware...

Page 16: ...et hub use a straight through Ethernet cable not supplied 2 Connect one end of the blue WAN cable to the port labeled WAN and plug the other end into the wall jack 3 Connect up to four telephone lines to the four POTS ports 4 Connect the power cable to your unit 5 Plug the other end of the power cable into a wall outlet Note The unit has no power switch and connecting the power cable turns on the ...

Page 17: ... and remains on If not on make sure the power supply is properly connected The act light blinks during any LAN traffic Otherwise it remains off The lnk light is on if an Ethernet connection is established If not on check to make sure your Ethernet cable is properly connected The wan light blinks until a DSL connection is established and then it remains on The con light is on only during the CellPi...

Page 18: ...AD CellPipe units Refer to the CellPipe IAD User s Guide for a discussion of the Main menu items The menu exception for the CellPipe IAD 4A can be found in its Configure WAN menu To configure the WAN interface on the CellPipe IAD 4A unit proceed as follows 1 Select Configure WAN from the Main Menu 2 Select Configure Physical Interface under the WAN Configuration menu 3 Set the ADSL Standard See Ta...

Page 19: ...n supports symmetrical transmission and receive rates of 1 544 Mbps Connecting a CellPipe IAD 8T unit The CellPipe IAD box you receive contains the following items 1 CellPipe IAD unit 2 10BaseT Ethernet crossover cable yellow 3 T1 WAN cable blue 4 Power supply 5 CellPipe IAD User s Guide 6 Hardware Installation Guide Connecting a CellPipe IAD 8T unit 9 Checking the activity of CellPipe IAD 8T stat...

Page 20: ...t hub use a straight through Ethernet cable not supplied 2 Connect one end of the blue WAN cable to the port labeled WAN and plug the other end into the wall jack 3 Connect up to eight telephone lines to the eight POTS ports 4 Connect the power cable to your unit 5 Plug the other end of the power cable into a wall outlet Note The unit has no power switch and connecting the power cable turns on the...

Page 21: ...ht is on initially and remains on If not on make sure the power supply is properly connected The lan lnk light is on if an Ethernet connection is established If not on check to make sure your Ethernet cable is properly connected The lan act light blinks during any LAN traffic Otherwise it remains off The wan lnk light blinks until a connection is established and then it remains on The voice light ...

Page 22: ...those of other IAD CellPipe units Refer to the CellPipe IAD User s Guide for a discussion of the Main menu items The menu exception for the CellPipe IAD 8T can be found in its Configure WAN menu To configure the WAN interface on the CellPipe IAD 8T unit proceed as follows 1 Select Configure WAN from the Main Menu 2 Select Configure Physical Interface under the WAN Configuration menu 3 Set the desi...

Page 23: ...3 to 266 Feet 3 266 to 399 Feet 4 399 to 533 Feet 5 533 to 655 Feet 6 0 7 5 dB 7 0 15 dB 8 0 22 5 dB Enable Disable B8ZS Enables and disables bipolar 8 zero substitution B8ZS line code Configure Transmit Channels Allows you to set the number of transmission channels maximum 24 for the WAN interface Configure Receive Channels Allows you to set the number of receive channels maximum 24 for the WAN i...

Page 24: ......

Page 25: ... IAD 4A and CellPipe IAD 8T Hardware Installation Guide 15 Connector Pinouts TERMINAL pinouts 10 100 LAN connector pinouts Pin Signal 1 GND 2 Tx Data 3 Rx Data Pin Signal 1 Tx 2 Tx 3 Rx 4 NC 5 NC 6 Rx 7 NC 8 NC ...

Page 26: ... pinouts 16 CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide T1 Connector pinouts ADSL connector pinouts Pin Signal 1 Rx Ring 2 Rx Tip 3 NC 4 Tx Tip 5 Tx Ring 6 NC 7 NC 8 NC Pin Signal 1 NC 2 NC 3 Tip 4 Ring 5 NC 6 NC ...

Page 27: ...rates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is unlikely to cause harmful interference But if it does the user will be required to correct the interference at his or her own expense The authority to operate this equipm...

Page 28: ...n must be used to install the equipment The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cau...

Reviews: