Summary of Contents for 4001-9403

Page 1: ...ems Installation and Operating Instructions 0 1995 Simplex Time Recorder Co FA4 21 004 574 047 All specifications and other information shown were current as of publication and are subject to change w...

Page 2: ...Contact your local Simplex Time Recorder Co Branch Office listed in the Yellow Pages under Fire Alarm for Warranty Registration Information firealarmresources com...

Page 3: ...1 OPERATING INSTRUCTIONS Introduction 23 How to Recognize Normal Trouble and Alarm Indications 24 How to Operate the Panel During an Alarm Condition 24 How to Reset the Fire Alarm System Following an...

Page 4: ...firealarmresources com...

Page 5: ...ipal fire alarm system to energize its electromagnetic tripping mechanism See definition for local energy master box Zone A designated area of a building Commonly zones within a building are annunciat...

Page 6: ...tion l Red LEDs indicate an alarm condition when on l Amber LEDs indicate a trouble condition when on Switches allow you to interact with the system in various ways see Operating Instructions on Page...

Page 7: ...occupants fire department or monitoring facility etc of the installation l When running wires to control panel identify wires appropriately 12OVAC input power notification signal circuit zone 1 zone...

Page 8: ...be run in the same conduit pipe raceway or multiconductor cables 5 Where system wires pass through floors or fire rated walls the installation shall be made to prevent the spread of fire from floor t...

Page 9: ...ut used can supply up to 500MA of filtered regulated 24VDC Max loop line resistance for each circuit is 50 ohms if P wire detectors are used Alarm Notification Appliance Wiring Afarm notification appl...

Page 10: ...ow Pages under Fire Alarm If you wish you may go directly to the detailed instructions to install the system Page 8 INSTALLATION CHECK LIST DETAILED q Procedure INSTRUCTION SEE PAGE S Mount control pa...

Page 11: ...remove appropriate jumpers JW4 JW5 JW6 and JW7 refer to 13 Step 7 Table 4 and appropriate resistors R84 R85 R86 and R87 If using an alarm relay module connect it to terminals on TB2 and TB3 If 0 12 us...

Page 12: ...e up with pin 9 on each connector 7 If using external battery cabinet mount it using the instruction provided with the cabinet The battery cabinet should be close nippled to the control panel maximum...

Page 13: ...nstallation instructions packed with the devices Connect a 3 3K end of line resistor EOLR across the terminals of the last device in each initiating circuit and mark the device accordingly see Figure...

Page 14: ...circuit make sure that all smoke detector heads are mounted and seated in their bases F Repeat Steps 1A thru 1E for all zone circuits 2 Check system s other external circuits as follows A Locate wire...

Page 15: ...10 2 Connect indicating appliance circuit to TB2 5 SIG and TB2 6 SIG Fig 18 Note If the system contains the transient suppressor board connect notification circuit to instead of the panel terminals s...

Page 16: ...nals designated for zones 3 and 4 see Page 13 4 If the system contains coded manual stations connect stations to zone 1 and cut jumper JW2 Fig 12 4 If the system contains 4 wire detectors do the follo...

Page 17: ...annunciator with remote trouble station and remote acknowledge switch connect to panel as follows see Fig 16 page 14 for reference Notes 1 Perform only Steps 7A through 7C if you are installing the 4...

Page 18: ...devices are used connect them to trouble relay as follows Refer to Fig 17 The trouble relay may be used to operate external circuits These external circuits may contain horns bells lights or other dev...

Page 19: ...e AUX 1 relay If devices are to be turned off during alarm connect lead from remote devices to TB5 8 the normally closed N C contact of the AUX 1 relay C Repeat steps 1 thru 3 for the AUX 2 relay if u...

Page 20: ...lack power lead hot to black lead from transformer input Connect white power TO 120 VAC lead neutral to white lead from transformer FUSED OUTLET input Fig 20 14 PERFORM THIS STEP ONLY IS USING THE BAT...

Page 21: ...e harness supplied with the control panel and use the harness supplied with the battery cabinet Connections are described below Note that you must run the harness through the knockout in the battery c...

Page 22: ...3 814 TRANSIENT SUPPRESSOR BOARD COMBINATION TRANSIENT SUPPRESSOR ZONE DISCONNECT BOARD ZONE DISCONNECT BOARD IMPORTANT WHEN NO WIRES ARE CONNECTED TO ZONE INITIATING TERMINALS CONNECT A 3 3K EOLR AC...

Page 23: ...4 4 ZON2 TB4 5 ZON3 TB4 6 ZON3 TB4 7 ZON4 TB4 8 ZON4 4 Connect water flow sprinkler circuits if used to suppressor disconnect or combination board as follows A Connect the waterflow switch normally op...

Page 24: ...VERIFICATION SIGNAL CUTOUT SIGNAL CUTOUT FIGURE 23 TABLE 4 GROUP 4 GROUP 5 GROUP 6 GROUP 1 GROUP 3 GROUP 3 GROUP 3 C Simple Coding notification appliance pulses indicate zone in alarm OFF OFF CODED IN...

Page 25: ...E LED SIGNAL TROUBLE LED and the four ZONE ALARM and TROUBLE LED S illuminate for five seconds The tone device sounds for l 2 second and the green AC POWER ON LED illuminates continuously Note If only...

Page 26: ...end of the white jumper to positive terminal of one battery and other end to negative terminal of other battery Fig 25 l The POWER TROUBLE and SYSTEM TROUBLE LEDs go out and the tone device sounds 5...

Page 27: ...tion on Page 26 for details The system constantly checks for electrical troubles opens shorts grounds abnormal city connections power loss low battery voltage etc If a trouble condition occurs the ton...

Page 28: ...g the alarm HOW TO OPERATE THE PANEL DURING AN ALARM CONDITION Important Consult local code authorities for specific actions to be taken during an alarm condition l When appropriate unlock and open th...

Page 29: ...ing that the water to the sprinkler system has been shut off l The notification appliances are still operating l The tone device is sounding a slow pulse indicating that the water to the sprinkler sys...

Page 30: ...t remove the circuit from the panel terminals see Page 10 Building Wiring Checkout Procedure and the system wiring diagram 841 610 provided with the panel ALARM VERIFICATION FEATURE OPTIONAL The 4001...

Page 31: ...ove wires from TB2 5 SIG and TB2 6 SIG or if the suppressor board is used TBl 9 SIG and TBi 10 SIG on the suppressor board are UII Then connect a IOK resistor across the terminals If the indicators go...

Page 32: ...another device Note Auxiliary relays and city connection do not operate during test l Momentarily open then reconnect any device wiring initiating devices and notification appliances to test for prope...

Page 33: ...device sounds for l 2 second The SYSTEM TROUBLE LED SIGNAL TROUBLE LED and the four ZONE ALARM and TROUBLE LEDs illuminate for five seconds If any of these LEDs do not illuminate contact your local S...

Page 34: ...s with very low capacity or shorted cells Important A defective battery charger circuit can cause battery failure Check the condition of the battery charger when either a battery tester or a voltage r...

Page 35: ...9 or less Retest battery after charging INSTRUCTIONS Put in Service See Note 1 l Charge Battery See Note 1 Discard Battery See Note 2 Note 1 Discard if battery has been in service for four or more ye...

Page 36: ...firealarmresources com...

Page 37: ...firealarmresources com...

Page 38: ...firealarmresources com...

Page 39: ...firealarmresources com...

Page 40: ...Ed495 amSimplex Simplex Plaza l Gardner Massachusetts 01441 0001 U S A FA4 21 004 574 047 1 firealarmresources com...