background image

 

 

 

 
 

Declaration of China RoHS Conformity

 

 
 
In order to reduce the impacts on the environment and take the more responsibility for protecting the 
earth, MEAN WELL is confirming and announcing the conformity to China RoHS, an 
Administrative Measures for the Restriction of the Use of Hazardous Substances in Electrical and 
Electronic Products.   
 

 
Environment Friendly Use Period Label 
 

 

Observing SJT 11364-2014, Marking for the Restricted Use of Hazardous 
Substances in Electronic and Electrical Products 
 
Observing SJ/Z 11388-2009, General Guidelines of Environment-friendly 
Use Period of Electronic Information Products Appendix B, adopting 
table look-up to verify the Environment Friendly Use Period 

 

 
Names and Contents of Hazardous Substances Lists 

 

Part Name 

Hazardous Substances 

Lead 

 

(Pb) 

Mercury

 

 

(Hg) 

Cadmium 

 

(Cd) 

Hexavalent 

chromium 

(Cr

6+

Polybrominated 

biphenyls 

(PBB) 

Polybrominated 

diphenyl ethers 

(PBDE) 

PCB and its 

components 

Metal structure 

parts 

Plastic structure 

parts 

Accessories 

Cables 

O: The concentration of the hazardous substances within the homogeneous material of that product is less than 

the concentration limits set by GB/T 26572-2011. 

X: The concentration of the hazardous substances within the homogeneous material of that product is over the 

concentration limits set by GB/T 26572-2011; however, it follows the standard advised by 2011/65/EU.

 

 

Summary of Contents for MEAN WELL MDR Series

Page 1: ... 1 8A 50 60Hz OUTPUT 5V 10A MDR 60 12 INPUT 100 240VAC 1 8A 50 60Hz OUTPUT 12V 5A MDR 60 24 INPUT 100 240VAC 1 8A 50 60Hz OUTPUT 24V 2 5A MDR 60 48 INPUT 100 240VAC 1 8A 50 60Hz OUTPUT 48V 1 25A MDR 100 12 INPUT 100 240VAC 1 3A 50 60Hz OUTPUT 12V 7 5A MDR 100 24 INPUT 100 240VAC 1 3A 50 60Hz OUTPUT 24V 4A MDR 100 48 INPUT 100 240VAC 1 3A 50 60Hz OUTPUT 48V 2A Introduction MDR is a DIN rail power s...

Page 2: ... 5 Recommended wire strapping length is 6 5mm 0 255 6 Recommended screwdriver is 3mm slotted type 7 The recommended torque setting for terminals is 5 kgf cm 4 4 Lb in 8 Suggested fuse and maximum number of the MDR PSUs that can be connected to a circuit breaker at 230V are shown as below Model Fuse Circuit breaker C16 D16 MDR 10 T2A L250V 11 22 MDR 20 T2A L250V 9 18 MDR 40 T2 5A L250V 6 13 MDR 60 ...

Page 3: ...ect system from supply voltage Before commencing any installation maintenance or modification work Disconnect your system from supply voltage Make sure that inadvertent connection in circuit will be impossible 11 For continued protection against risk of fire replace only with same type and rating of fuse Pour ne pas compromettre la protection contre les risqué d incendie remplacer par un fusible d...

Page 4: ...roducts Appendix B adopting table look up to verify the Environment Friendly Use Period Names and Contents of Hazardous Substances Lists Part Name Hazardous Substances Lead Pb Mercury Hg Cadmium Cd Hexavalent chromium Cr6 Polybrominated biphenyls PBB Polybrominated diphenyl ethers PBDE PCB and its components X O X O O O Metal structure parts X O O O O O Plastic structure parts O O O O O O Accessor...