Nodes
RSSI
Name of the LockNode
Signal strength of the LockNode
connection to the searching Router-
Node
Unit of signal strength
The WaveNet Manager displays the signal strength as an RSSI value
(Received Signal Strength) in dBm. This value is:
Logarithmic: In practice, an improvement of 10 dBm means twice the
signal strength.
Negative: The theoretical best value is 0 dBm and is only achieved by
cable connections. The closer the value is to 0 dBm (i.e. the smaller the
amount), the better the reception.
1. Mark the known LockNodes with bad connection in the middle column
(nodes of other segments) if the RSSI value is better.
You can see the current RSSI values in the main window of the Wave-
Net Manager.
2. Use drag and drop to move the LockNodes to the left-hand column
(nodes in this segment) to assign them to the current RouterNode
(which you used to search).
9
LockNodes are assigned to the current RouterNode.
NOTE
Assignment duration
When you reassign LockNodes, the WaveNet Manager communicates with
the LockNodes to transfer the configuration and check the LockNode. This
check takes a few seconds
3. If necessary, confirm the IO configuration of the LockNode by clicking
the OK (you can change the IO configuration at any time, see
figuration and protection functions [
9
LockNodes are assigned to the RouterNode.
5.5.2 Device restart
5.5.2.1 RouterNodes
Restarting Ethernet Router Nodes via the Browser Interface
ü
Browser interface open (see
1. Via | ADMINISTRATION | open the tab [REBOOT].
9
Now you see the restart menu.