EN 60079-11 (Equipment protection by intrinsic
safety "i")
3 Classification
The transponder is classified as follows:
Explosion Protection Zone
1
Intrinsic safety
ib
Explosion group
IIC
Temperature class
T3
Device group
II2 G
This applies to areas where a potentially explosive
atmosphere may occur due to gases, vapours or
mist. The information given refers to an ambient
temperature between -20 °C and +40 °C in the
area of use.
4 Emissions
Radio emis-
sions
SRD
24.50 kHz - 25.06
kHz
-20 dBµA/m (10 m
distance)
RFID (depending on
equipment)
13.564 MHz - 13.564
MHz
-19.57 dBµA/m (10
m distance)
There are no geographical restrictions within the
EU.
5 Declaration of conformity
The company SimonsVoss Technologies GmbH
hereby declares that article TRA2.G2.EX complies
with the following guidelines:
TRA2.G2.EX
3. Classification
10 / 40