Signal test
LED
Signal quality
flashes one time
poor
flashes two times
OK
flashes three times
Optimum
7. Hardware reset of external LockNodes
You can reset WaveNet Manager-enabled LockNodes (re-
cognisable by WN
M
in the article number):
1.
Disconnect the LockNode from the power supply or re-
move the batteries.
2. Wait for about 20 seconds.
3. Press and hold the Init button.
4. Reconnect the power supply or replace the batteries.
9
LED lights up constantly red.
5. Release the Init button while the LED is constantly red.
9
All WaveNet information in the LockNode is deleted.
You can re-integrate the LockNode into your WaveNet (see
WaveNet manual).
7. Hardware reset of external LockNodes